# Using energy: food, materials, mobility and buildings: Buildings and appliances

Source page: https://www.materialinsights.org/learn/energy/using-energy/p5/

[Understanding Energy](https://www.materialinsights.org/learn/energy/) / [Module 11: Using energy: food, materials, mobility and buildings](https://www.materialinsights.org/learn/energy/using-energy/) Part 5 of 5

## Buildings and appliances

Homes, offices, shops and public buildings use about a third of final energy, mostly for heat, cooling and appliances. Unlike steel mills, buildings are millions of small decisions by owners and tenants. That makes efficiency cheap in principle and slow in practice. For India, the story is dominated by cooking fuels and the rise of air conditioning.

### 5.1 Building energy is mostly low-temperature heat, but the mix depends on climate and income

Buildings use energy for space heating, water heating, cooking, cooling, lighting and a long list of appliances and electronics. In cold, rich countries such as Germany or northern China, space heating dominates, often more than half of household energy, and comes mostly from natural gas, oil, coal or district heat. In hot countries cooling grows with income. In poorer homes across South Asia and Africa, cooking dominates, and much of it still uses wood, dung, crop residues or charcoal on open fires or simple stoves.

Those open fires are among the least efficient converters in use. Smil puts open-fire cooking below 10% efficiency: most of the heat escapes around the pot. A liquefied petroleum gas (LPG) burner delivers perhaps 50 to 60% of its fuel's energy to the pot, and an induction hob over 80% of its electricity. So when a household switches from wood to LPG, its final energy use can fall sharply even as it cooks more, and indoor smoke, a leading cause of illness, falls too. India's push to connect poor households to LPG is, in energy terms, a large efficiency programme as well as a health one.

Almost all building heat is needed at low temperatures, under about 60 degrees Celsius for rooms and water. That is important. Burning gas at over 1,000 degrees to warm a room to 21 degrees wastes most of the fuel's thermodynamic potential, even if the boiler is 90% efficient by the usual measure. Heat pumps, which move ambient heat rather than create it, are the natural match for low-temperature needs. Good insulation, airtightness and shading reduce the need in the first place, and they last for the life of the building.

Value chain Where energy goes in buildings

- **Energy in buildings**

  - **Heat**

    - **Space heating (dominant in cold climates)**
    - **Water heating**
    - **Cooking (dominant in poorer homes)**

  - **Cooling**

    - **Air conditioners and fans**
    - **Refrigerators and freezers**

  - **Electrical services**

    - **Lighting**
    - **Appliances, motors and pumps**
    - **Electronics and IT**

 Source: Smil, Energy: A Beginner's Guide (2006), via Smil Mastery Course, M1 'Conservation and efficiency'  In the data

#### Cooking efficiency ladder

Approximate share of fuel energy that reaches the pot: open wood fire, under 10%; improved biomass stove, 20 to 30%; kerosene stove, about 45%; LPG or piped natural gas, 50 to 60%; electric resistance coil, about 70%; induction hob, over 80%. Each step up the ladder usually cuts indoor air pollution as well as energy use, and saves time once spent gathering fuel.

- Smil, Energy: A Beginner's Guide (2006) · via Smil Mastery Course, M1 'Conservation and efficiency'
- [United Nations Statistics Division, Energy Statistics Yearbook 2023, Table 3: Total final consumption and its components (2023 data)](https://unstats.un.org/unsd/energystats/pubs/yearbook/2023/t03.pdf (world 2023: total final consumption 418,723 PJ; industry 134,055; transport 100,542; other 139,235; non-energy use 44,891; international bunkers not included)) · web

### 5.2 Cooling is the fastest-growing use in buildings, and the efficiency gap is large

Since 2000, space cooling has been the fastest-growing energy use in buildings, rising by more than 4% a year according to the IEA's Energy Efficiency 2025 report. The driver is simple: rising incomes in hot, populous countries. India, Indonesia and much of Africa are only at the start of air-conditioner ownership. A single split air conditioner can draw 1 to 2 kilowatts, more than every other appliance in a typical Indian home combined, and many run during the evening peak when grids are most strained.

An air conditioner is a heat pump running in reverse. It uses a compressor and a refrigerant to move heat from inside to outside. Its performance is measured by how many units of heat it moves per unit of electricity. Efficient units move five or more. Cheap units move closer to three. That gap is mostly a matter of better compressors, larger heat exchangers and variable-speed motors, not new science.

The IEA's estimate of the gap is striking. Had every air conditioner sold worldwide since 2019 been the most efficient model available, the world would have avoided extra electricity demand about as large as the growth in demand from data centres over the same period. Many appliances on sale today are only half as efficient as the best on the market.

The lesson for investors is that minimum efficiency standards and labels, such as India's star-rating scheme for air conditioners and refrigerators, can shift a very large and fast-growing load at almost no extra cost to the grid. Building design matters as well. Shading, light-coloured roofs, ceiling fans and insulation can cut cooling needs before any machine is bought, and every kilowatt avoided at peak saves generation, transmission and distribution capacity.

Process flowchart How an air conditioner moves heat Inputs **Electricity**1 kWh **Heat taken from the room**3 to 5 kWh Process steps 1 **Evaporator indoors**

cold refrigerant absorbs heat from room air
 2 **Compressor**

electric motor squeezes the refrigerant vapour, raising its temperature
 3 **Condenser outdoors**

hot refrigerant releases heat to outside air
 Outputs **Heat dumped outside**4 to 6 kWh

The ratio of heat moved to electricity used is about 3 for cheap units and 5 or more for the best.
 Source: IEA, Energy Efficiency 2025: Executive summary, International Energy Agency, 2025, https://www.iea.org/reports/energy-efficiency-2025/executive-summary  Case

#### Peak load in Indian cities

On hot evenings, air conditioning can make up a large share of electricity demand in cities such as Delhi. Because the peak sets how much generation and grid capacity must be built, a more efficient air conditioner saves more than its share of energy. It also saves capital in power plants and wires that would otherwise run for only a few hundred hours a year.

- [IEA, Energy Efficiency 2025: Executive summary, International Energy Agency, 2025](https://www.iea.org/reports/energy-efficiency-2025/executive-summary) · web
- Smil, Energy: A Beginner's Guide (2006) · via Smil Mastery Course, M1 'Conservation and efficiency'

### 5.3 Lighting shows how much a better converter can save across a whole chain

Lighting is the cleanest illustration of Smil's point that converters, not just fuels, shape energy use. An incandescent bulb turns only about 2 to 5% of its electricity into visible light. The rest is heat. Now follow the whole chain from coal. A coal power plant turns about 38% of the coal's energy into electricity. Transmission and distribution deliver about 93% of that to the home. The bulb turns about 5% into light. Multiply the steps and only about 1.8% of the coal's energy becomes light.

Swap the bulb for an LED and the chain improves about six to seven times without any change at the power station. That is why the global shift to LEDs over the past fifteen years has been one of the largest and cheapest efficiency gains in history. The IEA notes that the efficiency of the best light bulbs doubled in fifteen years, while minimum standards rose by only about 30%, so the average bulb on sale still lags the best.

The same multiplication logic applies to every appliance. A refrigerator runs all day, every day, for fifteen years, so a small gain in its compressor and insulation adds up to a large saving. Electric motors in pumps and fans, which use a large share of the world's electricity, can often cut their use by a fifth or more with variable-speed drives that match output to need.

The pattern is consistent. The energy wasted at the end of the chain is multiplied back up the chain. Saving one unit at the bulb, the motor or the compressor saves two to three units of fuel at a thermal power plant. That is why efficiency at the point of use is often the cheapest supply of all.

Process flowchart From coal to light Inputs **Coal**100 units Process steps 1 **Thermal power plant**

about 38% to electricity; 62 units leave as heat
 2 **Transmission and distribution**

about 93% delivered
 3 **Incandescent bulb**

about 5% to visible light
 4 **or LED**

about 30 to 35% to visible light
 Outputs **Light from incandescent bulb**about 1.8 units **Light from LED**about 11 to 12 units Source: Smil, Energy: A Beginner's Guide (2006), via Smil Mastery Course, M1 'Conservation and efficiency'  Worked example

#### Coal to light, then and now

Coal plant 38% x grid 93% x incandescent bulb 5% = about 1.8% of the coal's energy delivered as light. Replace the bulb with an LED at about 30 to 35% and the chain delivers about 11 to 12%. Same coal, same plant, same wires, more than six times the light. Put another way, the LED needs only about a sixth of the coal for the same reading lamp.

- Smil, Energy: A Beginner's Guide (2006) · via Smil Mastery Course, M1 'Conservation and efficiency'
- [IEA, Energy Efficiency 2025: Executive summary, International Energy Agency, 2025](https://www.iea.org/reports/energy-efficiency-2025/executive-summary) · web

### See it in the table
[H₂O Water](https://www.materialinsights.org/commodities/water/)[Gas Natural gas](https://www.materialinsights.org/energy/natural_gas/)[Amb Ambient heat](https://www.materialinsights.org/energy/e_ambient/)[DC Data centres](https://www.materialinsights.org/energy/e_data_centres/)

### Check your understanding

Why does switching a household from an open wood fire to LPG often reduce its final energy use?
 The jump in stove efficiency is large enough that total fuel energy falls even if cooking increases. LPG's energy density is high but not the reason.

The IEA says that if all air conditioners sold since 2019 had been best-in-class, the avoided demand would roughly equal:
 This comparison from Energy Efficiency 2025 shows how large the gap between average and best appliances is in a fast-growing end use.

In the coal-to-light chain, swapping an incandescent bulb for an LED improves the overall result about:
 The bulb's efficiency rises from about 5% to 30 to 35%, so the whole chain improves by the same factor, about six to seven times, without changing the power plant.

[← Part 4: Moving people and goods](https://www.materialinsights.org/learn/energy/using-energy/p4/)[Mark read · Wrap-up →](https://www.materialinsights.org/learn/energy/using-energy/review/)

## Other sections

- [Module overview](https://www.materialinsights.org/learn/energy/using-energy/index.md)
- [Where final energy goes](https://www.materialinsights.org/learn/energy/using-energy/p1/index.md)
- [Food: nitrogen, ammonia and fossil-fuelled farms](https://www.materialinsights.org/learn/energy/using-energy/p2/index.md)
- [Materials: steel, cement, plastics and aluminium](https://www.materialinsights.org/learn/energy/using-energy/p3/index.md)
- [Moving people and goods](https://www.materialinsights.org/learn/energy/using-energy/p4/index.md)
- [Key terms, quiz and sources](https://www.materialinsights.org/learn/energy/using-energy/review/index.md)