# Electric generator: Footprint

Source page: https://www.materialinsights.org/products/p_electric_generator/prod-footprint/

#### Raw materials in one unit

Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions

| Variant | Material | Amount (kg) | Through | Emission factor (kg CO2e per kg) | Emissions (kg CO2e) |
|---|---|---|---|---|---|
| Synchronous | Steel | 53,926 | – | 1.92 | 103,537.9 |
| Synchronous | Copper | 5184 | – | 3.965 | 20,554.6 |
| Synchronous | Timber | 3040 | – | – | – |
| Synchronous | Aluminium | 192 | – | 14.8 | 2841.6 |
| Permanent | Steel | 53,282 | – | 1.92 | 102,301.4 |
| Permanent | Copper | 20,466 | – | 3.965 | 81,147.7 |
| Permanent | Iron ore | 7523.76 | Permanent magnet | – | – |
| Permanent | Rare earths | 3271.2 | Permanent magnet | – | – |
| Permanent | Nickel | 119.944 | Permanent magnet | – | – |
| Permanent | Boron | 109.04 | Permanent magnet | – | – |
| Diesel | Steel | 45.98 | Internal combustion engine | 1.92 | 88.3 |
| Diesel | Aluminium | 45.98 | Internal combustion engine | 14.8 | 680.5 |
| Diesel | Polypropylene | 5.22 | Internal combustion engine | 1.548 | 8.1 |
| Diesel | Copper | 2.09 | Internal combustion engine | 3.965 | 8.3 |
| Diesel | EPDM | 2.09 | Internal combustion engine | – | – |

Worked out from data

#### The site's estimate

Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors

| Variant | Stage | Place | Emissions (kg CO2e) | Mass covered by factors |
|---|---|---|---|---|
| Synchronous | Making | World | 189,690 | 95% |
| Synchronous | Use | World | 46.6 million | 100% |
| Synchronous | Making | India | 210,148 | 95% |
| Synchronous | Use | India | 68.2 million | 100% |
| Permanent | Making | World | 253,366 | 87% |
| Permanent | Use | World | – | – |
| Permanent | Making | India | 285,729 | 87% |
| Permanent | Use | India | – | – |
| Diesel | Making | World | 785 | 98% |
| Diesel | Use | World | – | – |
| Diesel | Making | India | 785 | 98% |
| Diesel | Use | India | – | – |

Worked out from data

#### Energy to make it

Energy used to make one unit, by carrier and stage
 Energy to make

- [El Electricity](https://www.materialinsights.org/energy/electricity/) 347,400 MJ · Manufacturing Synchronous (ABB GBA 1120, 31 MW) 96,500 kWh of electricity to make the 31 MW machine, converted at 3.6 MJ per kWh (calculated) ^[1].
- [Ht Heat](https://www.materialinsights.org/energy/heat/) 264,600 MJ · Manufacturing Synchronous (ABB GBA 1120, 31 MW) 73,500 kWh of heat, converted at 3.6 MJ per kWh (calculated); the declaration's table columns are not clearly aligned ^[1].

as of 2026-11-13

#### Energy in use

Energy one unit uses per year of use, by carrier
 Energy in use

- [El Electricity](https://www.materialinsights.org/energy/electricity/) 4.07 million kWh per year · lifetime 25 years Synchronous (ABB GBA 1120, 31 MW) Electricity lost as heat, not consumed fuel: the declaration gives 101,760,000 kWh of electrical energy in the usage phase, over 25 years (calculated per year) ^[1]. This matches 31,000 kW at 98.02% efficiency over 6,500 hours a year (about 626 kW lost). The generator's real input is shaft power from the turbine or engine.

as of 2026-11-13. Fuel use of diesel sets is per hour in Key specifications; hours per year vary too much to total.

#### Emissions by stage

Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant

| Stage | Value | Unit | Share | Variant | Place | Source |
|---|---|---|---|---|---|---|
| Making | 245,520 | kg CO2e per generator | 0.5 | Synchronous (ABB GBA 1120, 31 MW) | World | Calculated from ^[1]: manufacturing 7.92 kg CO2 per kW times 31,000 kW |
| Use | 52.6 million | kg CO2e per generator | 99.5 | Synchronous (ABB GBA 1120, 31 MW) | World | Calculated from ^[1]: usage phase 1,698 kg CO2 per kW times 31,000 kW, over 25 years at 6,500 hours a year |

as of 2026-11-13. The declaration gives total life cycle 1,706 kg CO2 per kW (52.9 million kg for 31,000 kW, calculated). It reports no separate transport or end-of-life figure; the gap between the total and the two stages shown is within rounding. Permanent magnet and diesel variants have no per-generator figure in the sources found [1].

#### End of life

What happens to a unit when it is thrown away: collection, reuse, recycling and disposal shares, by place

| Route | Share | Place | Year | Source |
|---|---|---|---|---|
| Recyclable metals in a 3,750 kVA diesel generating set (Kohler KD3750-F) | 94 | France (made); World | 2024 | ^[8] |
| Main parts of the large ABB generators can be recycled; some parts must be fragmented to separate the materials | – | World | – | ^[1]^[2] |

as of 2026-11-13

#### Recovered as

The commodities and chemicals recovered at end of life, with recovery rates
 Recovered as

- [St Steel](https://www.materialinsights.org/commodities/steel/) Recycling Cores, frame and structure; the Kohler declaration says over 94% of the set is recyclable metals ^[8].
- [Cu Copper](https://www.materialinsights.org/commodities/copper/) Recycling Winding copper; no recovery rate for generators found ^[8].
- [REE Rare earths](https://www.materialinsights.org/commodities/rare_earths/) Recycling Magnet recycling is not described in the generator sources found.

as of 2026-11-13

#### End of life in India

Collection and recycling in India, including the informal sector

The sources found give no end-of-life data for India. ABB says the main parts of its large generators can be recycled but some parts must be fragmented to separate the materials ^[1]. Kohler says a 3,750 kVA set is over 94% recyclable metals ^[8]. How magnets are recovered from retired wind generators is not described in the sources found.

as of 2026-11-13

#### Sources

1. [Environmental Product Declaration for AC-machine type GBA 1120](https://library.e.abb.com/public/ee15c7d3e61cd7cbc1256d63003f8a41/EPD%20for%20GBA1120.pdf) ABB (Generators and motors, EPD under the 2000 product-specific requirements for rotating electrical machines)
2. [Environmental Product Declaration AC generator type AMG 0900, 5125 kVA power](https://library.e.abb.com/public/e87da12604e15ba4c125784f00380043/EPD_AMG0900_EN_RevB.pdf) ABB
3. [Kohler publishes product lifecycle analysis](https://www.electronicspecifier.com/industries/alternative-energy/kohler-publishes-product-lifecycle-analysis/) Electronic Specifier, 2024

## Other sections

- [Summary](https://www.materialinsights.org/products/p_electric_generator/index.md)
- [Working](https://www.materialinsights.org/products/p_electric_generator/prod-working/index.md)
- [Bill of materials](https://www.materialinsights.org/products/p_electric_generator/prod-bom/index.md)
- [Use case](https://www.materialinsights.org/products/p_electric_generator/prod-use/index.md)
- [Supply chain](https://www.materialinsights.org/products/p_electric_generator/prod-supply/index.md)
- [Evolution](https://www.materialinsights.org/products/p_electric_generator/prod-evolution/index.md)
- [Interventions](https://www.materialinsights.org/products/p_electric_generator/prod-interventions/index.md)