# Electrolyser: Bill of materials

Source page: https://www.materialinsights.org/products/p_electrolyser/prod-bom/

#### About these figures

Which unit, study and year the composition figures describe, and how they vary

Alkaline: a 5 MW plant of two stacks, 90,958 kg in Table 2's Mass Total column (stated 90,959), divided by 5 for one MW (calculated), 2025 ^[8]; several rows do not multiply out, so the column is used as given. PEM: one unit labelled 'Electrolyzer (PEM, 1 MW unit)', 2022 ^[7]. Not counted: concrete, control electronics (1,100 kg), organic chemicals, activated carbon, plywood, polysulfone and iridium (0.75 kg, no node). No solid oxide inventory was found.

as of 2026-11-13

#### Components

The products inside one unit, with quantity, mass share and cost share
 Variant **Alkaline**

| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| [Transformer and power converter](https://www.materialinsights.org/products/p_transformer_and_power_converter/) | Component | 2.2 | **33.7%** |
| The 5 MW alkaline plant has 11 inverters (Table 2), 2.2 per MW (calculated). Their rows (steel 15,818, lubricating oil 9,691, copper 3,685, aluminium 1,441 kg) total 30,635 kg of 90,958 kg, 33.7% by mass (calculated) ^[8]. These materials are counted only here, not in prod_bom.materials. The PEM inventory lists no separate rectifier. |  |  |  |

as of 2026-11-13

#### Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content
 Variant 1 **Alkaline**

| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| [St Steel](https://www.materialinsights.org/commodities/steel/) | Structural | 7775 kg | **42.7%** |
| Stainless, low-alloyed and chromium steel plus 615 kg of cast iron, outside the inverter: 38,875 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [Ni Nickel](https://www.materialinsights.org/commodities/nickel/) | Functional | 2170.6 kg | **11.9%** |
| Electrodes, mesh and bipolar plates: 10,853 kg of nickel in the 5 MW plant, plus 42 kg of nickel sulfide on the cathodes. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [EPDM EPDM](https://www.materialinsights.org/chemicals/epdm/) | Structural | 632.8 kg | **3.5%** |
| EPDM rubber gaskets, 3,164 kg in the 5 MW plant (464 gaskets), incinerated at end of life. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [Cu Copper](https://www.materialinsights.org/commodities/copper/) | Functional | 403 kg | **2.2%** |
| Copper plates, busbars and pumps, outside the inverter: 2,015 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [LLDPE Polyethylene (LDPE, LLDPE)](https://www.materialinsights.org/chemicals/polyethylene/) | Structural | 162.6 kg | **0.9%** |
| Separator plates 304, potassium hydroxide tank 362 and control unit and cable 147 kg: 813 kg in the 5 MW plant. Polysulfone (70 kg), plywood housing (3,800 kg) and synthetic rubber (5 kg) have no node and are not counted. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [Zr Zirconium](https://www.materialinsights.org/commodities/zirconium/) | Functional | 78.8 kg | **0.4%** |
| Zirconium oxide in the separator membrane: 394 kg in the 5 MW plant, as oxide. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [Al Aluminium](https://www.materialinsights.org/commodities/aluminum/) | Structural | 41.8 kg | **0.2%** |
| Control unit, outside the inverter: 209 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |
| [PTFE Fluoropolymers (PTFE, PVDF)](https://www.materialinsights.org/chemicals/fluoropolymers/) | Structural | 16.6 kg | **0.09%** |
| Polyvinyl fluoride in the control unit and cable, 83 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) ^[8]. |  |  |  |

 Variant 2 **PEM**

| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| [St Steel](https://www.materialinsights.org/commodities/steel/) | Structural | 6800 kg | **74%** |
| Stack 100 kg of 18/8 chromium steel, balance of plant 1,900 kg of chromium steel and 4,800 kg of low-alloyed steel (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) ^[7]. |  |  |  |
| [Ti Titanium](https://www.materialinsights.org/commodities/titanium/) | Functional | 528 kg | **5.7%** |
| Stack plates and porous layers, 528 kg of primary titanium per 1 MW unit; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) ^[7]. |  |  |  |
| [PP Polypropylene](https://www.materialinsights.org/chemicals/polypropylene/) | Structural | 300 kg | **3.3%** |
| Polypropylene granulate in the balance of plant, 300 kg per 1 MW unit; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) ^[7]. |  |  |  |
| [Al Aluminium](https://www.materialinsights.org/commodities/aluminum/) | Structural | 127 kg | **1.4%** |
| Stack 27 kg and balance of plant 100 kg (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) ^[7]. |  |  |  |
| [Cu Copper](https://www.materialinsights.org/commodities/copper/) | Functional | 104.5 kg | **1.1%** |
| Stack 4.5 kg and balance of plant 100 kg (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) ^[7]. |  |  |  |
| [PTFE Fluoropolymers (PTFE, PVDF)](https://www.materialinsights.org/chemicals/fluoropolymers/) | Functional | 13.2 kg | **0.14%** |
| Tetrafluoroethylene, the precursor the inventory uses for the membrane polymer; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) ^[7]. |  |  |  |
| [Pt Platinum](https://www.materialinsights.org/commodities/platinum/) | Functional | 0.075 kg | **0.001%** |
| Platinum catalyst, 0.075 kg per 1 MW unit. The 0.75 kg of iridium in the same stack has no node of its own, so it stays in the notes and is not counted here ^[7]. |  |  |  |

as of 2026-11-13

#### How it is put together

The main steps from parts and materials to the finished unit

| Step | What happens | Technology | Source |
|---|---|---|---|
| Make the cell parts | Electrodes, separators or membranes, frames and bipolar plates are made and coated with catalyst. | – | ^[8]^[7] |
| Stack the cells | Hundreds of cells are pressed between end plates into a stack; Table 2 of the 5 MW alkaline reference lists 232 cells, and most stack totals are twice the per-plant quantity, consistent with 232 cells in each of its two stacks. | – | ^[8] |
| Build skids | Stacks are mounted on skids with pumps, separators and cooling; a 100 MW PEM project uses 50 skids and 150 stacks. | – | ^[12] |
| Add power and control | A rectifier, control unit and cabling are added to turn grid power into direct current. | Transformers and power electronics | ^[8] |
| House and test | The units are placed in a housing or building and tested before commissioning. | – | ^[8] |

as of 2026-11-13

#### Technologies inside it

The technologies inside the product, with how much of each per unit
 Embodies

- [Elz Electrolysers](https://www.materialinsights.org/technologies/e_electrolysers/) 1 MW The electrolysis technology itself.
- [PE Transformers and power electronics](https://www.materialinsights.org/technologies/e_power_electronics/) A rectifier (the inverter rows of the reference) and control unit turn grid power into direct current; the inverters are 33.7% of the alkaline reference mass (calculated) ^[8].

as of 2026-11-13

#### Sources

1. [Large-scale hydrogen production via water electrolysis: a techno-economic and environmental assessment, Electronic Supplementary Information](https://www.rsc.org/suppdata/d2/ee/d2ee01023b/d2ee01023b1.pdf) Royal Society of Chemistry (Terlouw, Bauer, McKenna, Mazzotti, Energy & Environmental Science), 2022, Tables A1, A2 and A4
2. [Reducing Environmental Impacts of Water Electrolysis Systems by Reuse and Recycling: Life Cycle Assessment of a 5 MW Alkaline Water Electrolysis Plant](https://mdpi.com/1996-1073/18/4/796) Energies 18(4), 796, MDPI (Annika C. Hoppe and Christine Minke), 2025, Table 2
3. [Deliverable 9.4, GHG emissions avoidance analysis report (pre-construction)](https://2.refhyne.eu/wp-content/uploads/2025/11/REFHYNE-2-D9.4-pre-construction-GHG-avoidance-report-final2.pdf) TECNALIA for the REFHYNE 2 project, 2025, Sections 5.1 to 5.3; dated March 2025

## Other sections

- [Summary](https://www.materialinsights.org/products/p_electrolyser/index.md)
- [Working](https://www.materialinsights.org/products/p_electrolyser/prod-working/index.md)
- [Use case](https://www.materialinsights.org/products/p_electrolyser/prod-use/index.md)
- [Supply chain](https://www.materialinsights.org/products/p_electrolyser/prod-supply/index.md)
- [Footprint](https://www.materialinsights.org/products/p_electrolyser/prod-footprint/index.md)
- [Evolution](https://www.materialinsights.org/products/p_electrolyser/prod-evolution/index.md)
- [Interventions](https://www.materialinsights.org/products/p_electrolyser/prod-interventions/index.md)