# MRI scanner: Evolution

Source page: https://www.materialinsights.org/products/p_mri_scanner/prod-evolution/

#### Timeline

The milestones of the product, each with a source

| Year | Event |
|---|---|
| 1973 | Paul Lauterbur shows that adding gradient magnets to the main magnet lets a cross section be pictured ^[9] |
| 1977 | FONAR's Indomitable makes the first human MRI image, of a chest, on 3 July ^[10] |
| 1980 | FONAR says it sells its first scanner, the QED 80, to Dr. Ronald J. Ross for his facility in Cleveland, Ohio, and introduces the first commercial whole-body scanner ^[22]^[10] |
| 2002 | About 22,000 MRI cameras are in use worldwide and more than 60 million examinations are done ^[9] |
| 2024 | Philips counts more than 1,000 sealed BlueSeal systems with 7 litres of helium ^[4]; Siemens introduces MAGNETOM Flow with 0.7 litres ^[5] |
| 2025 | A press report says VoxelGrids has developed India's first indigenous 1.5T scanner, with no liquid helium ^[13] |
| 2026 | Siemens Healthineers plans to open its magnet site in North Oxfordshire ^[16] |

as of 2026-11-13

#### Recipe changes

How what it is made of changed over time, and what drove each change

| Change | From | To | Driver | Source |
|---|---|---|---|---|
| Helium charge of the magnet | About 1,500 litres of liquid helium in a conventional magnet ^[4]^[5]^[6] | 7 litres sealed (Philips BlueSeal) or 0.7 litres (Siemens DryCool) ^[4]^[5] | Siemens says MAGNETOM Flow cuts installation requirements and costs ^[5]; a Siemens article says the helium supply from the US has dried up in recent years ^[6] | ^[4]^[5]^[6] |
| Magnet weight | Philips Ingenia 1.5T zero boil-off (ZBO) magnet | BlueSeal magnet, 900 kg lighter | Philips does not state a reason in the release | ^[4] |

as of 2026-11-13

#### What could improve it next

Directions for improvement, today's value and the limit

| Direction | Metric | Today | Unit | Source |
|---|---|---|---|---|
| Less helium per magnet | Liquid helium in a magnet | 0.7 | litres (Siemens DryCool; no floor stated) | ^[5] |
| Less cooling energy | Cut in cooling energy with Siemens' optional Green Cooling Package, up to (maker's claim, MAGNETOM Sola) | 39 | % (Munich climate data; no limit stated) | ^[1] |

as of 2026-11-13

#### Sources

1. [MAGNETOM Sola Environmental Product Declaration](https://marketing.webassets.siemens-healthineers.com/97042c1a7955e256/722da1605d27/SH-MR_MAGNETOM_Sola_EPD_flyer.pdf) Siemens Healthcare GmbH, 2020, product materials, power consumption, cumulative energy demand, life cycle of replacement parts and operating environment tables; recyclability text; 1.5T system
2. [Philips extends leadership in virtually helium-free MRI with more than 1,000 systems installed](https://www.philips.com/a-w/about/news/archive/standard/news/press/2024/philips-extends-leadership-in-virtually-helium-free-mri-with-more-than-1000-systems-installed-expanding-patient-access-worldwide.html) Philips, 2024, press release of 28 February 2024
3. [Siemens Healthineers introduces MAGNETOM Flow for greater sustainability and efficiency in MRI](https://www.siemens-healthineers.com/en-uk/press-room/press-features/magnetom-flow) Siemens Healthineers, 2024, page dated 12 March 2024
4. [MRI's Helium Footprint – And How to Make it Harder to Spot](https://marketing.webassets.siemens-healthineers.com/4b19d50eeb37c7c8/7e8d1669173f/magnetom-world-siemens-healthineers-vonGraetz_Helium_Sustainability.pdf) Siemens Healthineers (Philipp Grätzel von Grätz, M.D.), article; the page shows no publication date
5. [The Nobel Prize in Physiology or Medicine 2003: press release (6 October 2003)](https://nobelprize.org/prizes/medicine/2003/press-release) Nobel Assembly at Karolinska Institutet (nobelprize.org), 2003, press release of 6 October 2003
6. [FONAR History](https://fonar.com/history.html) FONAR Corporation
7. [VoxelGrids Unveils India’s First Indigenous MRI Scanner](https://www.gktoday.in/voxelgrids-unveils-indias-first-indigenous-mri-scanner) GKToday, 2025, article of 29 December 2025
8. [Siemens Healthineers announces £250m Oxford facility, the UK’s first major production site for new MRI cooling technology](https://www.siemens-healthineers.com/en-uk/press-room/press-features/oxford-facility-announcement) Siemens Healthineers, 2024, page dated 10 May 2024
9. [FONAR Innovation Timeline](https://www.fonar.com/innovations-timeline.html) FONAR Corporation, 1980 entry, First Commercial MRI

## Other sections

- [Summary](https://www.materialinsights.org/products/p_mri_scanner/index.md)
- [Working](https://www.materialinsights.org/products/p_mri_scanner/prod-working/index.md)
- [Bill of materials](https://www.materialinsights.org/products/p_mri_scanner/prod-bom/index.md)
- [Use case](https://www.materialinsights.org/products/p_mri_scanner/prod-use/index.md)
- [Supply chain](https://www.materialinsights.org/products/p_mri_scanner/prod-supply/index.md)
- [Footprint](https://www.materialinsights.org/products/p_mri_scanner/prod-footprint/index.md)
- [Interventions](https://www.materialinsights.org/products/p_mri_scanner/prod-interventions/index.md)