# Stent: Bill of materials

Source page: https://www.materialinsights.org/products/p_stent/prod-bom/

#### About these figures

Which unit, study and year the composition figures describe, and how they vary

No source gives the mass of a stent or its materials in grams. The materials come from one FDA summary for a cobalt-chromium drug-eluting stent (Xience V), two reviews and a maker's patient page, so they describe the main platforms, not one product. The delivery balloon catheter is not a node and is listed in new_products.

as of 2026-11-13

#### Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content
 Variant 1 **Not stated**

| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| [St Steel](https://www.materialinsights.org/commodities/steel/) | Structural | Not given | – |
| Most early stents were stainless steel and balloon-expandable ^[5]; Medtronic says a stent can be made of medical-grade stainless steel ^[4]. No source gives the mass. |  |  |  |
| [Ni Nickel](https://www.materialinsights.org/commodities/nickel/) | Structural | Not given | – |
| Self-expanding nitinol stents are a nickel and titanium alloy ^[5]; Table 1 of a 2010 review gives L605 cobalt-chromium as 10% nickel by weight (table value) ^[1]. No stent mass is given. |  |  |  |
| [Ti Titanium](https://www.materialinsights.org/commodities/titanium/) | Structural | Not given | – |
| Nitinol, the shape memory alloy of some self-expanding stents, is made of nickel and titanium ^[5]. No source gives the mass. |  |  |  |

 Variant 2 **Drug-eluting**

| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| [Co Cobalt](https://www.materialinsights.org/commodities/cobalt/) | Structural | Not given | – |
| The XIENCE V stent is a medical-grade L-605 cobalt-chromium alloy ^[3]; later platforms used cobalt-chromium instead of stainless steel to make them more flexible ^[5]. No source gives the mass. |  |  |  |
| [Cr Chromium](https://www.materialinsights.org/commodities/chromium/) | Structural | Not given | – |
| Chromium is the partner metal in the cobalt-chromium and platinum-chromium stent alloys ^[2]^[3]. No source gives the mass. |  |  |  |
| [Pt Platinum](https://www.materialinsights.org/commodities/platinum/) | Structural | Not given | – |
| Some new-generation stents use platinum-chromium, which is denser than stainless steel or cobalt-chromium ^[1]^[2]. No source gives the mass. |  |  |  |
| [PTFE Fluoropolymers (PTFE, PVDF)](https://www.materialinsights.org/chemicals/fluoropolymers/) | Functional | Not given | – |
| The XIENCE V drug matrix layer is PVDF-HFP, a copolymer of vinylidene fluoride and hexafluoropropylene; a poly n-butyl methacrylate layer bonds it to the stent ^[3]. No source gives the mass. |  |  |  |
| [API Small-molecule APIs](https://www.materialinsights.org/chemicals/apis/) | Functional | Not given | – |
| Drug-eluting stents carry an antiproliferative drug, everolimus in the XIENCE V ^[3]; no amount is given here. |  |  |  |

Indicative · as of 2026-11-13. No amount per stent was found: the sources name materials but not masses.

#### How it is put together

The main steps from parts and materials to the finished unit

| Step | What happens | Technology | Source |
|---|---|---|---|
| Alloy | A stainless steel, cobalt-chromium or platinum-chromium alloy is chosen for the platform ^[2] | – | ^[2] |
| Cutting | A thin metal tube is cut by laser into the mesh; a 2024 review says laser cutting transformed stent design ^[6] | Laser | ^[6] |
| Surface treatment | Surfaces are treated to improve biocompatibility, as an equipment maker describes it ^[16] | – | ^[16] |
| Coating | For drug-eluting stents a polymer carrier holding the drug is coated on the metal ^[6]^[3] | – | ^[6]^[3] |
| Mounting | The stent is mounted on the balloon of its delivery catheter ^[4] | – | ^[4] |
| Testing | Each stent is tested against safety and efficacy standards, as an equipment maker describes it ^[16] | – | ^[16] |

as of 2026-11-13

#### Technologies used to make it

The technologies used to make it, at which step
 Made with

- [Lsr Laser](https://www.materialinsights.org/technologies/laser/) Cutting the thin metal tube into the stent mesh A 2024 review says laser cutting technology transformed stent design and describes laser-cut tubular stents; no share of output is given ^[6].

as of 2026-11-13

#### Technologies inside it

The technologies inside the product, with how much of each per unit
 Embodies

- [Stn Coronary stent](https://www.materialinsights.org/technologies/coronary_stent/) The scaffold technology is the twin node; one stent is one mesh tube.

as of 2026-11-13

#### Sources

1. [Does the Metal Matter? An overview of next-generation stent platforms.](https://assets.bmctoday.net/citoday/pdfs/cit0510_feature_cannon.pdf) Cardiac Interventions Today, May/June 2010 (Cannon, Daniel, Hood and Yakubov), 2010, pp. 41 to 47; strut thickness text; Table 1, nominal elemental composition by weight
2. [State of the art: coronary artery stents – past, present and future](https://eurointervention.pcronline.com/article/state-of-the-art-coronary-artery-stents-past-present-and-future/pdf) EuroIntervention (Stefanini, Byrne, Windecker and Kastrati), 2017, EuroIntervention 2017;13:706-716
3. [Summary of Safety and Effectiveness Data, XIENCE V Everolimus Eluting Coronary Stent System (PMA P070015)](https://www.accessdata.fda.gov/cdrh_docs/pdf7/P070015b.pdf) US Food and Drug Administration (applicant Abbott Vascular, Cardiac Therapies), 2008, FDA notice of approval 2 July 2008; device description
4. [What Is Balloon Angioplasty and Stenting?](https://www.medtronic.com/uk-en/patients/treatments-therapies/heart-surgery-cad/balloon-angioplasty-stenting-what-is-it.html) Medtronic (UK patient site)
5. [Modern Stents: Where Are We Going?](https://rmmj.org.il/issues/45/1080/manuscript) Rambam Maimonides Medical Journal (Kobo and others), 2020, RMMJ 2020;11(2):e0017, DOI 10.5041/RMMJ.10403
6. [Inception of the coronary stent: a story of successful collaboration between innovative scientists and the biotechnology industry](https://scielo.isciii.es/pdf/recic/v6n4/en_2604-7306-recic-6-4-321.pdf) REC: Interventional Cardiology 6(4):321-331 (Macaya-Ten, Gonzalo, Escaned, Macaya), 2024
7. [What is the manufacturing process of a heart stent?](https://go.aerotech.com/in-motion/understanding-heart-stent-manufacturing-process) Aerotech, a maker of laser and motion equipment (In Motion blog), 2026, published 28 April 2026; an equipment maker's own material, not a peer-reviewed source

## Other sections

- [Summary](https://www.materialinsights.org/products/p_stent/index.md)
- [Working](https://www.materialinsights.org/products/p_stent/prod-working/index.md)
- [Use case](https://www.materialinsights.org/products/p_stent/prod-use/index.md)
- [Supply chain](https://www.materialinsights.org/products/p_stent/prod-supply/index.md)
- [Footprint](https://www.materialinsights.org/products/p_stent/prod-footprint/index.md)
- [Evolution](https://www.materialinsights.org/products/p_stent/prod-evolution/index.md)
- [Interventions](https://www.materialinsights.org/products/p_stent/prod-interventions/index.md)