# Variable speed drive: Use case

Source page: https://www.materialinsights.org/products/p_variable_speed_drive/prod-use/

#### Use cases

Each use, its share of demand and volume, how critical the product is to it and why, and the price paid

| Use case | Volume | Unit | Criticality | Reason | Year | Source |
|---|---|---|---|---|---|---|
| Pumps in variable-flow duty (water supply, circulation, process) | 36 | TWh a year of further EU savings possible with drives, 2020 market data | Important | Throttle valves can control flow, but they waste energy that a drive avoids. | 2020 | ^[2]^[15] |
| Fans (ventilation, HVAC, cooling) | 70.3 | TWh a year of further EU savings possible with drives, 2020 market data | Important | Dampers can control airflow at an energy penalty; the drive removes the penalty. | 2020 | ^[15] |
| Compressors with variable load | 14.8 | TWh a year of further EU savings possible with drives, 2020 market data | Important | Fixed-speed compressors can load and unload, at a cost in energy; the study says HVAC applications already have an 85% drive share for variable loads in the EU. | 2020 | ^[15] |
| Constant-torque machinery (conveyors, cranes, mixers, positive displacement pumps) | – | – | Important | Speed control can also come from DC drives or mechanical gearing, at a cost; input power varies linearly with speed, so the energy gain is smaller. | 2012 | ^[1] |
| Commercial building services (HVAC pumps and fans) | 1412 | TWh a year of motor electricity used in commercial buildings worldwide | Important | Building fans and pumps often run at part load, where speed control saves energy; valves and dampers are the alternative. | 2006 | ^[17] |

as of 2026-11-17

#### Industries that buy it

The industries and kinds of firm that buy it, for which use case, and how critical it is to them
 Used by 4

- [Water and sanitation](https://www.materialinsights.org/industries/water_sanitation/) Water supply and circulation pumps · criticality important Circulating water systems are a typical drive application ^[2]; no demand share found.
- [Paper and packaging](https://www.materialinsights.org/industries/paper_packaging/) Pulp and paper mills · criticality important Pulp and paper is one of the end-use segments listed for AC drives ^[29].
- [Metal products](https://www.materialinsights.org/industries/metal_products/) Metals (the metals part of the 'mining and metals' segment) · criticality important Mining and metals is one of the end-use segments listed for AC drives ^[29]; only the metals part is linked here.
- [Real estate](https://www.materialinsights.org/industries/real_estate/) Commercial building HVAC · criticality important Commercial buildings use 20% of motor system electricity worldwide (2006) ^[17].

as of 2026-11-17

#### How it is used

Lifetime, use per year and utilisation, by variant

| Measure | Value | Unit | Variant | Place | Year | Source |
|---|---|---|---|---|---|---|
| Reference service life, Danfoss and Schneider declarations | 10 | years | Standard drive | EU | 2026 | ^[3]^[4]^[5] |
| Reference service life, ABB and Siemens declarations | 15 | years | Standard drive | EU | 2025 | ^[8]^[9] |
| Active hours in the Danfoss use scenario, at an average 80% load | 6000 | hours per year | Standard drive | EU | 2026 | ^[3] |
| Operating hours in the Siemens and ABB scenarios | 5000 | hours per year | Standard drive | EU | 2025 | ^[8]^[9] |
| Share of industrial motors controlled by drives (ABB white paper, a vendor claim) | 25 | % | Standard drive | World | 2025 | ^[16] |
| Share of EU motors already fitted with a drive, lowest to highest by unit power | 1 to 54 | % | Standard drive | EU | 2020 | ^[15] |

as of 2026-11-17

#### Prices

Unit prices by market or use, with year and source

| Market | Value | Unit | Year | Source |
|---|---|---|---|---|
| Schneider ATV630D37N4 (37 kW), UK distributor, before VAT | 4345.95 | GBP | 2026 | ^[11] |
| Schneider ATV630D37N4 (37 kW), Danish distributor, before VAT | 53,178.9 | DKK | 2026 | ^[12] |

as of 2026-11-17

#### Sources

1. [Adjustable Speed Drive Part-Load Efficiency, Motor Systems Tip Sheet #11](https://www.energy.gov/sites/prod/files/2014/04/f15/motor_tip_sheet11.pdf) US Department of Energy, 2012
2. [Control Strategies for Centrifugal Pumps with Variable Flow Rate Requirements (Pumping Systems Tip Sheet #12, DOE/GO-102007-2230)](https://nrel.gov/docs/fy07osti/38949.pdf) US Department of Energy, Industrial Technologies Program, 2007
3. [Environmental Product Declaration iC7-Automation, Frame FA08 (EPD-IES-0025739:001)](https://assets.danfoss.com/documents/latest/586226/BI498839834253en-000103.pdf) Danfoss A/S (The International EPD System), 2026
4. [Product Environmental Profile: ATV930 160KW 400V with braking unit (ATV930C16N4), ENVPEP1903002_V1](https://efobasen.efo.no/API/Produktfiler/LastNed?id=1230543) Schneider Electric (PEP ecopassport), 2019
5. [Product Environmental Profile: ATV630 CAB INT IP00/UL type 12 90KW 400V WO KEYPAD (ATV630D90N4ZU), ENVPEP2007013_V1](https://mouser.com/datasheet/2/357/1/ENVPEP2007013EN_V1-2490317.pdf) Schneider Electric (PEP ecopassport), 2020
6. [ABB general machinery drives, ACS350, 7.5 kW: Environmental product declaration](https://library.e.abb.com/public/943d18282cd8147ac1257403003c1f82/EPD-ACS350-EN.pdf) ABB, 2008
7. [Environmental Product Declaration NEPD-11916-11779: SINAMICS G220, frame size FSD1](https://cache.industry.siemens.com/dl/files/299/109991299/att_1335312/v1/NEPD-11916-11779_SINAMICS-G220.pdf) Siemens AG (The Norwegian EPD Foundation), 2025
8. [Schneider Electric Inverter Drive, 37 kW, 3 Phase, ATV630 Series 480V 74.5 A (listing 8724079)](https://uk.rs-online.com/web/p/inverter-drives/8724079) RS Components UK, 2026
9. [Schneider Electric ATV630D37N4 (listing 25649190)](https://www.digikey.dk/en/products/detail/schneider-electric/ATV630D37N4/25649190) DigiKey Denmark, 2026
10. [Study on the energy-saving potential of electric motors with variable-speed drives in the European Union, final report](https://www.zvei.org/fileadmin/user_upload/Verband/Fachverbaende/Automation/Elektrische_Antriebe/Cemep_Studie/Cemep_Fraunhofer_study-motor-saving-potential-with-VSD-20231215.pdf) Fraunhofer ICT (Schröder, Liebertseder and Doppelbauer) for CEMEP, 2023
11. [Efficient motors and drives could cut global energy use by up to 10%](https://drivesncontrols.com/efficient-motors-and-drives-could-cut-global-energy-use-by-up-to-10/) Drives & Controls (reporting the ABB white paper 'Achieving the COP28 UAE Consensus'), 2025
12. [Energy-Efficiency Policy Opportunities for Electric Motor-Driven Systems (Energy Efficiency Series working paper)](https://iea.blob.core.windows.net/assets/d69b2a76-feb9-4a74-a921-2490a8fefcdf/EE_for_ElectricSystems.pdf) International Energy Agency (Waide and Brunner), 2011
13. [AC Drives Market Size & Share, Growth Forecasts Report 2034](https://gminsights.com/industry-analysis/ac-drives-market) Global Market Insights, 2024

## Other sections

- [Summary](https://www.materialinsights.org/products/p_variable_speed_drive/index.md)
- [Working](https://www.materialinsights.org/products/p_variable_speed_drive/prod-working/index.md)
- [Bill of materials](https://www.materialinsights.org/products/p_variable_speed_drive/prod-bom/index.md)
- [Supply chain](https://www.materialinsights.org/products/p_variable_speed_drive/prod-supply/index.md)
- [Footprint](https://www.materialinsights.org/products/p_variable_speed_drive/prod-footprint/index.md)
- [Evolution](https://www.materialinsights.org/products/p_variable_speed_drive/prod-evolution/index.md)
- [Interventions](https://www.materialinsights.org/products/p_variable_speed_drive/prod-interventions/index.md)