# Direct air capture: Levers

Source page: https://www.materialinsights.org/technologies/direct_air_capture/tech-levers/

Held back most by

Economics

The physics leaves room (the best published whole-plant analysis finds a second-law efficiency of 7.8%, about 13 times the minimum ^[16]), but removing a tonne costs an estimated USD 500 to 1,900 and Climeworks said Mammoth removed 675 tonnes in the first half of 2026 against a nameplate of 36,000 a year ^[4]^[13]^[17]. Energy at scale would bind later: 1 Gt a year at 1.2 MWh a tonne would need about 1,200 TWh, two thirds of India's 2024-25 generation (calculated) ^[11]^[15]. This is judgement.

#### The six layers

Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it

Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A **hard limit** comes from mathematics or nature and can only be sidestepped; a **soft limit** moves with effort, scale, money or policy.

1.  1 Mathematics Hard limit

Mathematics is the language of its physics

**What it gives.** A logarithm of dilution gives the least work to pull CO2 out of a gas, and for air at about 420 parts per million it is large ^[9].

**The idea.** Role: language. A physical law makes DAC costly and mathematics writes the cost down: the least work for N moles is N R T ln(1/f), where f is the share of the gas that is CO2 ^[9]. Air is about 420 to 430 parts per million CO2 ^[4], so ln(1/f) is near 7.8 (calculated), against 2.1 for 12% flue gas.

**The limit.** The least work rises with the logarithm of the dilution, whatever sorbent or machine is used ^[9].

**What could unlock it.** Only by changing the input: capture from a concentrated stream is the other technology on this site, and it does not remove CO2 already in the air.

[CCS Carbon capture and storage](https://www.materialinsights.org/technologies/carbon_capture_storage/)

Show the maths W = N × R × T × ln(1 ÷ f)

**W**
: the least work to take the CO2 out, in joules

**N**
: the moles of CO2 taken out

**R**
: the gas constant, about 8.314 joules for each mole for each kelvin (assumed)

**T**
: the temperature, in kelvin

**ln**
: the natural logarithm

**f**
: the share of the air, by number of molecules, that is CO2

**In plain words.** CO2 is spread very thin in air, about one molecule in 2,500. Gathering them up again is the opposite of mixing, and mixing happens for free. The more thinly it is spread, the more work it takes to gather it. Air is about 300 times thinner in CO2 than chimney gas, yet the bill is only about 3.7 times bigger, because it grows with the logarithm.

**Worked example.** At an assumed 298 K and f = 0.0004 (400 ppm, assumed): R × T = 2,478 J/mol and ln(1 ÷ 0.0004) = 7.824, so W = 19.4 kJ per mole (calculated), about 122 kWh per tonne of CO2 using 44.01 g/mol (calculated) ^[9]. The APS 2011 report's 21.86 kJ/mol is for taking out all of the CO2 ^[10].

2.  2 Science Hard limit

**What it gives.** The second law of thermodynamics sets the least work to separate CO2 from air, about 2.9 times that for coal flue gas (calculated from ^[10]).

**The idea.** APS puts the minimum for taking out all of the CO2 from air at 0.04% at 21.86 kJ/mol, or 497 kJ per kg, about 138 kWh a tonne (calculated) ^[10]. A 2022 analysis of Carbon Engineering's proposed 1 Mt a year liquid plant found it needs 273.2 MW of natural gas work potential where the reversible minimum, including compression, is 21.20 MW: a second-law efficiency of 7.8% ^[16].

**The limit.** The minimum is a floor: it corresponds to reversible processes happening infinitely slowly, and no real plant can reach it ^[10].

Second-law efficiency of a whole DAC plant, including compression

Today (2022): **7.8%** · Limit: **100%** · 8% of the way to the limit

A proposed design, not a measured plant: Carbon Engineering's 1 Mt a year natural-gas-powered process (after Keith et al. 2018), analysed in 2022 with input and minimum both as work and both including compression ^[16]. The node's 'about 20 times' compares heat input with separation work alone.

**What could unlock it.** The floor cannot be broken. Of the plant's 273.2 MW, 252 MW are lost to irreversibility ^[16]; APS names moving the air and releasing the CO2 from the sorbent as the large demands ^[10].

Show the maths ηII = Wrev ÷ Wact

**ηII**
: the second-law efficiency: the share of the work put in that the laws of nature truly require, a fraction

**Wrev**
: the least (reversible) work to capture and compress the CO2, in megawatts for a running plant

**Wact**
: the work the real plant uses, in megawatts

**In plain words.** Nature sets the least work a perfect machine would need. A real machine uses more, because some work is lost as waste heat and friction. Divide the least work by the real work and you get a score out of one. A perfect plant would score one.

**Worked example.** 21.20 MW ÷ 273.2 MW = 0.078, or 7.8% ^[16]; 1 ÷ 0.078 = about 13 times the minimum (calculated). The plant removes 111.9 tonnes an hour, so 273.2 ÷ 111.9 = 2.44 MWh of work for each tonne, about 8.8 GJ (calculated) ^[16].

3.  3 Engineering Soft limit

**What it gives.** Fans push air over a sorbent or through a liquid, and heat releases the CO2; solid systems need low-temperature heat and liquid ones need heat up to 900 °C ^[12].

**The idea.** The IEA says the lower temperature heat needs of the solid system mean it can be fuelled by renewable energy, while the high temperature heat of the liquid system underpins current plant designs that rely on natural gas ^[12]. Climeworks says two upgraded collector containers at its Icelandic plant reached the original peak daily run rate of 1.37 tonnes of CO2 a day ^[13].

**The limit.** Energy and sorbent performance: most proposed processes need the equivalent of at least 1.2 MWh of electricity for each tonne of CO2 removed ^[11].

**What could unlock it.** Low-temperature heat from a heat pump is a route for the solid system; this link is my judgement, not the source's.

[MVR Industrial heat pumps and vapour recompression](https://www.materialinsights.org/technologies/e_industrial_hp/)

4.  4 Production Soft limit

**What it gives.** Plants are built in modules, and so far each new design has had to be proved on site before it is repeated.

**The idea.** Climeworks said its Mammoth plant removed 675 tonnes of CO2 in the first half of 2026 ^[17]; a trade report gives 119 tonnes in the first half of 2025 and calls the 675 tonnes net removal ^[13]. Doubled, that is about 1,350 tonnes a year, near 4% of the 36,000 tonnes a year nameplate (calculated, assumed). This is the company's figure as reported by Bloomberg; Climeworks' own pages could not be opened.

**The limit.** The first large plant ran far below its nameplate and needed new sorbent and mechanical upgrades ^[13].

**What could unlock it.** The IEA's Net Zero Scenario needs an average of 32 large-scale plants of 1 Mt a year each to be built each year ^[12]: each would be about 28 times Mammoth's nameplate (calculated).

5.  5 Economics Soft limit Binds most today

**What it gives.** The price of removing a tonne is high because every tonne needs a great deal of air, energy and sorbent, and there are few buyers.

**The idea.** The IEA estimates that current projects cost USD 500 to 1,900 per tonne of CO2 ^[4], against its 2022 estimate of USD 125 to 335 for large-scale plants built today ^[12]. Advances could bring costs to around USD 300 a tonne by mid-century ^[4].

**The limit.** Cost: capital, energy and sorbent, set against few buyers; the IEA's 2025 estimate for current projects is well above its 2022 estimate for large plants, though the two are on different bases ^[4]^[12].

**What could unlock it.** The IEA says some next-generation designs target USD 100 per tonne ^[4]; with deployment and innovation it saw capture costs falling to under USD 100/tCO2 in 2022 ^[12].

Show the maths CRF = WACC × [1 ÷ (1 - 1 ÷ (1 + WACC)^t)]

**CRF**
: the capital recovery factor: the share of the up-front cost paid back each year

**WACC**
: the weighted average cost of capital, as a fraction a year

**t**
: the number of years the plant earns

**In plain words.** A DAC plant costs a lot before it captures anything. This equation says what slice of that cost must be earned back every year, with interest. The slice is large when the plant is dear, short-lived or financed at a high rate.

**Worked example.** Assumed: capital of USD 4,000 per tonne of annual capacity, WACC 10%, 20 years, power at USD 0.05/kWh, and 1.2 MWh a tonne ^[11]. CRF = 0.10 ÷ (1 - 1.10^-20) = 0.1175, so capital is USD 470 a tonne each year; power is 1,200 kWh × 0.05 = USD 60 a tonne (calculated) ^[14]. Capital, not electricity, dominates in this assumed case.

6.  6 Resources and rules Soft limit

**What it gives.** At world scale DAC is an energy problem: at least 1.2 MWh of electricity-equivalent for each tonne means large volumes of clean power ^[11].

**The idea.** One Mt a year needs 1.2 TWh a year, about 137 MW running all year (calculated from ^[11]). One Gt a year would need 1,200 TWh, about 66% of India's total generation of 1,829.698 BU (TWh) in 2024-25 (calculated) ^[15].

**The limit.** Clean energy and storage permission at gigatonne scale: the IEA's pathway of 32 large plants a year implies power and storage built at the same pace (judgement) ^[12].

**What could unlock it.** Heat needs that renewables can meet for solid systems ^[12], and storage in basalt where it turns to stone, as at Orca, Iceland (from the node's earlier tab, not reopened).

Show the maths electricity needed = CO2 removed × electricity for each tonne

**electricity needed**
: the power the plants draw over a year, in terawatt-hours

**CO2 removed**
: the CO2 captured in a year, in millions of tonnes

**electricity for each tonne**
: the energy for one tonne, at least 1.2 MWh for most proposed processes

**In plain words.** If each tonne of CO2 needs a fixed amount of energy, then more tonnes need more energy in step. A plant that takes out a million tonnes a year needs a power station of its own.

**Worked example.** 1 Mt × 1.2 MWh per tonne = 1.2 million MWh = 1.2 TWh a year; 1.2 TWh ÷ 8,760 hours = 137 MW (calculated) ^[11]. For 1 Gt a year, 1,200 TWh, against India's 1,829.7 TWh (calculated) ^[15].

as of 2026-11-24

#### Sources

1. [Driving down the cost of carbon removal: Why innovation matters (Carl Greenfield, Simon Bennett, Timur Gul)](https://www.iea.org/commentaries/driving-down-the-cost-of-carbon-removal-why-innovation-matters) International Energy Agency, 2025
2. [Carbon sequestration (physics problem, undated)](https://www2.oberlin.edu/physics/dstyer/99Problems/CarbonSequestration.pdf) Oberlin College, Department of Physics, 2026
3. [Direct Air Capture of CO2 with Chemicals: a technology assessment for the APS Panel on Public Affairs (Box 2.2)](https://infoscience.epfl.ch/record/200555/files/dac2011.pdf?version=1) American Physical Society, 2011
4. [Reality check on technologies to remove carbon dioxide from the air](https://news.mit.edu/index%2Ephp/2024/reality-check-tech-to-remove-carbon-dioxide-from-air-1120) MIT News, Massachusetts Institute of Technology, 2024
5. [Direct Air Capture 2022: Executive summary](https://www.iea.org/reports/direct-air-capture-2022/executive-summary) International Energy Agency, 2022
6. [Climeworks upgrades DAC tech at Iceland facility after low CO2 capture record (undated)](https://www.gasworld.com/story/climeworks-upgrades-dac-tech-at-iceland-facility-after-low-co2-capture-record/2259464.article/) gasworld (trade news), 2026
7. [Equations and Variables in the ATB (2024)](https://atb.nrel.gov/electricity/2024/equations_&_variables) NREL, 2024
8. [Power Sector at a Glance, All India (data to September 2025)](https://powermin.gov.in/sites/default/files/uploads/power_sector_at_glance_Sep_2025.pdf) Ministry of Power, Government of India, 2025
9. [Thermodynamic loss analysis of a liquid-sorbent direct air carbon capture plant (Long-Innes and Struchtrup, Cell Reports Physical Science 3, 100791)](https://engr.uvic.ca/~struchtr/2022_CRPS_DAC.pdf) Cell Press; author copy, University of Victoria, 2022
10. [Carbon removal pioneer Climeworks increases CO2 capture sixfold (Bloomberg, 10 September 2026)](https://www.energyconnects.com/news/renewables/2026/september/carbon-removal-pioneer-climeworks-increases-co2-capture-sixfold/) Energy Connects, republishing Bloomberg, 2026

## Other sections

- [Summary](https://www.materialinsights.org/technologies/direct_air_capture/index.md)
- [Overview](https://www.materialinsights.org/technologies/direct_air_capture/tech-overview/index.md)
- [Science](https://www.materialinsights.org/technologies/direct_air_capture/tech-science/index.md)
- [Evolution](https://www.materialinsights.org/technologies/direct_air_capture/tech-evolution/index.md)
- [Materials](https://www.materialinsights.org/technologies/direct_air_capture/tech-materials/index.md)
- [Energy footprint](https://www.materialinsights.org/technologies/direct_air_capture/tech-energy-footprint/index.md)
- [Industries](https://www.materialinsights.org/technologies/direct_air_capture/tech-industries/index.md)