# Data centres: Science

Source page: https://www.materialinsights.org/technologies/e_data_centres/tech-science/

#### Principles

The science it rests on, with why each principle matters to it
 Relies on

- [First law of thermodynamics](https://www.materialinsights.org/science/first_law_thermodynamics/) Energy is conserved, so all the electricity a server takes in leaves as heat that the building must remove.
- [Heat conduction (Fourier's law)](https://www.materialinsights.org/science/heat_conduction/) Heat has to flow from each chip through heat sinks or cold plates into air or water, which sets how densely chips can be packed.
 Limited by

- [Second law of thermodynamics](https://www.materialinsights.org/science/second_law_thermodynamics/) Landauer argued in 1961 that erasing a bit gives off at least kT ln 2 of heat, a floor for any computer ^[5].

as of 2026-11-10

#### Discoveries

The discoveries that made it possible: when, by whom and what was found

| Year | Who | What |
|---|---|---|
| 1761 | Joseph Black | Latent heat, the large heat taken in by a change of state, which evaporative cooling towers use ^[8] |
| 1824 | Sadi Carnot | The limit on any heat engine, and so on the chillers that pump heat out of a building, set by its temperatures ^[7] |
| 1961 | Rolf Landauer, IBM | Every logical operation is a physical one, and erasing information must release heat ^[5] |

as of 2026-11-10

#### Physical limits

The limits nature sets, today's best and how far there is still to go

| Limit | Value | Unit | Best today | Gap |
|---|---|---|---|---|
| PUE cannot fall below 1, when every watt reaches the computers | 1 | ratio | 1.09 across Google's fleet, 2025 ^[4] | The 2025 survey average was 1.54 ^[3] |
| Landauer limit: the least heat released in erasing one bit, kT ln 2 | – | J per bit | Today's CMOS chips use much more energy than this ^[5] | No figure for the gap in the sources opened |

as of 2026-11-10

#### The science explained

The science behind it explained for a curious reader

In energy terms a data centre is an electric heater that does arithmetic on the way. Every joule a chip takes in leaves as heat, so a site that draws 100 MW must shed 100 MW of heat, day and night. In 1961 Rolf Landauer argued that some of this heat can never be avoided: wiping out one bit of information must release at least a tiny amount, kT ln 2 ^[5]. Real chips release far more than that, and the building adds its own overhead for fans, pumps, chillers and power conversion. That overhead is what PUE measures. It fell from 2.5 in 2007 to 1.65 in 2014 but has barely moved since, standing at 1.54 in 2025 ^[3], while the best fleets reach 1.09 ^[4].

as of 2026-11-10

#### Sources

1. [Uptime Institute Global Data Center Survey 2025](https://datacenter.uptimeinstitute.com/rs/711-RIA-145/images/2025.Annual.Survey.Report.pdf?version=0) Uptime Institute, 2025
2. [Data centers: efficiency (power usage effectiveness)](https://datacenters.google/efficiency) Google, 2026
3. [Design of Reversible Computing Systems: Logic, Languages, and Circuits (M. K. Thomsen, PhD thesis, University of Copenhagen)](https://arxiv.org/pdf/2309.11832) arXiv (2309.11832), 2012
4. [June 12, 1824: Sadi Carnot Publishes Treatise on Heat Engines](https://aps.org/apsnews/2009/05/sadi-carnot-heat-engines) APS News, American Physical Society, 2009
5. [Joseph Black](https://en.wikipedia.org/wiki/Joseph_Black) Wikipedia

## Other sections

- [Summary](https://www.materialinsights.org/technologies/e_data_centres/index.md)
- [Overview](https://www.materialinsights.org/technologies/e_data_centres/overview/index.md)
- [Correlation](https://www.materialinsights.org/technologies/e_data_centres/correlation/index.md)
- [Science and limits](https://www.materialinsights.org/technologies/e_data_centres/science/index.md)
- [Value chain](https://www.materialinsights.org/technologies/e_data_centres/valuechain/index.md)
- [Unit economics](https://www.materialinsights.org/technologies/e_data_centres/economics/index.md)
- [Engineering methods](https://www.materialinsights.org/technologies/e_data_centres/methods/index.md)
- [Equipment and suppliers](https://www.materialinsights.org/technologies/e_data_centres/equipment/index.md)
- [Overview](https://www.materialinsights.org/technologies/e_data_centres/tech-overview/index.md)
- [Evolution](https://www.materialinsights.org/technologies/e_data_centres/tech-evolution/index.md)
- [Materials](https://www.materialinsights.org/technologies/e_data_centres/tech-materials/index.md)
- [Energy footprint](https://www.materialinsights.org/technologies/e_data_centres/tech-energy-footprint/index.md)
- [Industries](https://www.materialinsights.org/technologies/e_data_centres/tech-industries/index.md)
- [Relationships](https://www.materialinsights.org/technologies/e_data_centres/links/index.md)