# Masonry arch: Science

Source page: https://www.materialinsights.org/technologies/masonry_arch/tech-science/

#### Principles

The science it rests on, with why each principle matters to it
 Relies on

- [Statics of arches and the line of thrust](https://www.materialinsights.org/science/statics_line_of_thrust/) An arch stands if a line of thrust can be drawn that lies entirely within its masonry ^[5].
- [Newton's laws of motion](https://www.materialinsights.org/science/newtons_laws/) Every block is in balance: its weight is matched by the push of its neighbours, which is why the feet of an arch need sideways support.
 Limited by

- [Fracture mechanics](https://www.materialinsights.org/science/fracture_mechanics/) Masonry is treated as having no tensile strength ^[5], so any part of an arch pulled into tension cracks open into a hinge.

as of 2026-11-10

#### Discoveries

The discoveries that made it possible: when, by whom and what was found

| Year | Who | What |
|---|---|---|
| 1675 | Robert Hooke | A hanging chain, inverted, gives the shape of an arch in pure compression ^[5]^[6] |
| 1748 | Giovanni Poleni | First rigorous use of the hanging-chain idea to analyse a real structure, the dome of St Peter's in Rome ^[5] |
| 1833 | Henry Moseley | First rigorous statement of the line of thrust ^[5]^[10] |
| 1966 | Jacques Heyman | Limit analysis of masonry: no tensile strength, unlimited compression, no sliding ^[5]^[11] |

as of 2026-11-10

#### The science explained

The science behind it explained for a curious reader

Hang a chain between two hooks and it sags into a smooth curve. Every link is being pulled, and nothing in the chain is pushed. Now freeze that shape and turn it upside down. Every pull becomes a push, and the curve becomes an arch in which every block is only squeezed, never pulled apart. Robert Hooke hid this idea in an anagram in 1675; decoded, it reads: as hangs the flexible line, so but inverted will stand the rigid arch ^[5]^[6]. Stone and brick are superb at being squeezed and poor at being stretched, so the hanging-chain shape suits them perfectly. A real arch does not have to match that curve exactly. It only has to be thick enough that some such line of thrust fits inside it ^[5]. That is why old arches built by eye, with no calculations, have stood for two thousand years.

as of 2026-11-10

#### Sources

1. [Equilibrium Systems: Studies in Masonry Structure](http://web.mit.edu/masonry/papers/block_SMArchS_2005.pdf) Massachusetts Institute of Technology (Philippe Block, SMArchS thesis), 2005
2. [As Hangs the Flexible Line: Equilibrium of Masonry Arches](https://link.springer.com/doi/10.1007/s00004-006-0015-9) Nexus Network Journal, vol. 8 no. 2 (Block, DeJong and Ochsendorf), Springer, 2006
3. [Moseley, Henry (Dictionary of National Biography entry)](https://mathshistory.st-andrews.ac.uk/DNB/Moseley.html) MacTutor History of Mathematics, University of St Andrews
4. [Preface (Maurizio Angelillo and Santiago Huerta Fernandez), Journal of Mechanics of Materials and Structures 13(5)](https://msp.org/jomms/2018/13-5/p01.xhtml) Mathematical Sciences Publishers, 2018

## Other sections

- [Summary](https://www.materialinsights.org/technologies/masonry_arch/index.md)
- [Overview](https://www.materialinsights.org/technologies/masonry_arch/tech-overview/index.md)
- [Evolution](https://www.materialinsights.org/technologies/masonry_arch/tech-evolution/index.md)
- [Materials](https://www.materialinsights.org/technologies/masonry_arch/tech-materials/index.md)
- [Energy footprint](https://www.materialinsights.org/technologies/masonry_arch/tech-energy-footprint/index.md)
- [Industries](https://www.materialinsights.org/technologies/masonry_arch/tech-industries/index.md)