Ambient heat: Fluctuation in time

Coldest air exactly when heat is needed most

What this tab covers How availability changes over seconds, days, seasons, years and longer, how predictable it is, and what that means for the plants that use it.

The ground and large water bodies are steady sources; outdoor air swings daily and seasonally and is coldest exactly when heat is most needed, which lowers performance on the coldest days.

Variation by time scale

Time scaleWhat happensHow large
Daily and weatherAir temperature changes through the day and with cold spells; heat pump efficiency falls as the air cools.7UK median air-source efficiency 2.44 on days with mean temperature as low as -6 °C, vs 2.80 over the year
SeasonalHeat demand peaks in winter when air is coldest, so the source and the need are out of phase.8Field data from seven studies: typically two to three times as efficient as fossil boilers well below 0 °C, more than twice at -10 °C; efficiency (COP) still above 1.5 near -30 °C
Seasonal (ground)Shallow ground stays close to its annual mean temperature, so ground-source units hold their efficiency.210-16 °C in the upper 3 m
DecadesEquipment and ground loops are long-lived.3Heat pump 20+ years; underground loops 25-50 years

How predictable it is

High: performance follows outdoor temperature, which is forecast days ahead; the challenge is the peak electricity demand that cold snaps create, not unpredictability.

Capacity factors and utilisation

Plant or measureValue
Seasonal performance factor, air-source heat pumps (UK field trial, median, 742 heat pumps)2.807
Ground-source heat pump efficiency (US DOE)300-600%3

Ambient heat never runs out, but its quality changes with the weather. For air-source heat pumps, which are about 85% of heat pumps in buildings (REN21), every degree of outdoor cooling widens the temperature lift and lowers the heat delivered per unit of electricity, just as demand rises. Real-world data show the effect is gradual: a large UK field trial measured a median of 2.80 units of heat per unit of electricity over the year and 2.44 on days averaging -6 °C.

Ground and water sources avoid most of this swing because a few metres down the temperature barely changes through the year, which is why ground-source systems can use 25-50% less energy than air-source ones (US DOE).

Sources

  1. Geothermal Heat Pump Basics NREL
  2. Guide to Geothermal Heat Pumps US Department of Energy
  3. Heat pumps shown to be three times more efficient than gas boilers (Electrification of Heat demonstration) Energy Systems Catapult, 2023
  4. Coming in from the cold: Heat pump efficiency at low temperatures (Gibb, Rosenow, Lowes and Hewitt, Joule 7) Cell Press, 2023