LNG chain: Efficiency and losses
The tenth of the gas burned before a cargo even sails
LNG is energy-hungry: running the refrigeration plant consumes roughly a tenth of the gas before it leaves port, and a little more boils off each day at sea.
Chart: Efficiency ranges
Used to drive transport Lost in transitLosses by measure
| Measure | Range | Type | What is measured |
|---|---|---|---|
| Liquefaction energy use | 9 to 15%8531 | Used to drive transport | Gas burned to liquefy, as a share of the energy in the LNG: 4,200 to 7,400 MJ per tonne in life-cycle inventories, divided by about 48 MJ per kg (calculated). EIA estimates about 14% of US feed gas is used in liquefaction |
| Boil-off at sea, typical | 0.07 to 0.15% of cargo per day67 | Lost while held | Liquid evaporated by heat leaking into tanks; 0.15% per day was standard around 2010, new membrane systems are guaranteed at 0.07 to 0.085% |
| Boil-off over a 20-day voyage | 1.4 to 3%67 | Lost in transit | 0.07 to 0.15% per day times 20 days (calculated); mostly burned as ship fuel rather than wasted |
| Regasification energy | 0.1 to 0.7%8 | Used to drive transport | Gas used at the import terminal as a share of energy sent out, two life-cycle databases (calculated from 0.00085 to 0.0069 MJ per MJ); seawater vaporisers sit at the low end |
Holding periods and inventory
| Measure | Value |
|---|---|
| Import terminal use | World regasification capacity ran at only 38.6% on average in 2024, so much of it is standby security2 |
| Liquefaction plant use | 86.7% average utilisation in 20242 |
The big energy cost is at the start. Refrigeration compressors are usually driven by gas turbines, which turn only about 35% of fuel energy into shaft work, so roughly 9 to 15% of the energy in the gas is used to liquefy it (calculated from life-cycle data; EIA puts US plants at about 14% of feed gas). Electric drives fed by low-carbon power cut this.
At sea, heat leaking through the insulation boils off 0.07 to 0.15% of the cargo per day depending on tank design. Most is burned in the ship's engines, so it is fuel use rather than pure loss, and ships keep a small 'heel' of LNG to keep tanks cold on the way back. Regasification uses well under 1%. In total the LNG route uses several times more energy than a pipeline, which burns about 2 to 3% of its gas per 1,000 km (calculated).
Sources
- 2025 World LNG Report International Gas Union, 2025
- Natural gas deliveries to U.S. LNG export facilities set a record in first-half 2023 US EIA, Today in Energy, 2023
- Boil off rate (BOR) Wartsila Encyclopedia, 2024
- NO96 Super+ GTT, 2024
- Analysis of the greenhouse gas intensities of LNG imports to Germany (Munter and Liebich), final report ifeu for Wissenschaftsplattform Klimaschutz, 2023
- 2006 IPCC Guidelines for National Greenhouse Gas Inventories, Vol. 2, Ch. 1, Table 1.2 (default net calorific values) IPCC, 2006