Material Insights · Understanding the Material World

Radiotherapy: Levers

Held back most by

Economics

India had 794 megavoltage machines for a projected 1.45 billion people in 2025, about 0.55 per million (calculated), against an optimal target of four per million [11], so the gap is in funded, sited and staffed centres rather than in physics (judgement). Rules and licensing [12] are the close second.

The six layers

Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it

Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A hard limit comes from mathematics or nature and can only be sidestepped; a soft limit moves with effort, scale, money or policy.

  1. 1 Mathematics Hard limit

    Mathematics is the language of its physics

    What it gives. The geometry that tells a planner how a beam thins out with distance, so the treatment room and the beam can be designed on paper.

    The idea. Role: language. A physical fact, that a beam's energy spreads over a larger area the farther it travels, is written as power divided by area, and the area of a sphere is 4πr2[10]. Doubling the distance cuts the intensity to one quarter [10].

    The limit. Geometry cannot be beaten: from a small source the intensity falls with the square of the distance [10]. Real beams are also shaped, absorbed and scattered, so the rule gives only the first estimate (judgement).

    What could unlock it. Beam shaping, and aiming from several directions, are ways to work with the rule rather than against it (judgement).

    Show the maths I = P / A, with A = 4πr2
    I
    the intensity, power per unit area, in watts per square metre
    P
    the power leaving the source, in watts
    A
    the area the power has spread over, in square metres
    r
    the distance from the source, in metres

    In plain words. Think of a torch. Close to the torch the light is bright. Far away the same light is spread over a bigger patch, so it is dim. The patch grows with the square of the distance. Twice as far means a patch four times as big, so a quarter as bright.

    Worked example. Take a source of 1 watt (assumed). At 1 metre the area is 4π × 12 = 12.57 square metres and I = 1 / 12.57 = 0.080 W/m2 (calculated). At 2 metres the area is 50.27 square metres and I = 0.020 W/m2, one quarter as much (calculated) [10].

  2. 2 Science Hard limit

    What it gives. Two effects: radiation that carries enough energy to damage cells, and a machine or a radioactive material to make it. This page treats the second only as principle.

    The idea. The number of unstable nuclei in a radioactive material falls in a fixed pattern over time, set by a decay constant for that nucleus [9]. A linear accelerator instead makes its X-rays on demand by firing electrons at a metal target, so nothing radioactive is needed (node tab, tech_science).

    The limit. A radioactive material cannot be switched off: it decays at the rate its nucleus sets, whatever anyone wants [9].

    What could unlock it. The linear accelerator sidesteps the limit, because its beam exists only while the machine is powered; its price is a need for steady power and long downtime when it fails [13].

    Show the maths N = N0 e-λt
    N
    the number of radioactive nuclei left after time t
    N0
    the number at the start
    e
    the base of natural logarithms, about 2.718
    λ
    the decay constant for that nucleus, per unit of time (for example per year)
    t
    the time that has passed, in the same unit of time as λ

    In plain words. A radioactive material loses its unstable atoms over time. The same share goes in each equal stretch of time, so the loss slows as fewer are left. The decay constant tells you how fast. A big constant means a short-lived material. Nothing anyone does can speed it up or slow it down.

    Worked example. Take a decay constant of 0.1 per year (assumed, not a real source). After 10 years, N / N0 = e-0.1 × 10 = e-1 = 0.37 (calculated), so about 37% remains [9].

  3. 3 Engineering Soft limit

    What it gives. A machine that makes a shaped beam, aims it from many angles, and does so reliably day after day.

    The idea. Two designs coexist. Cobalt-60 units are cited as more robust to the challenges of resource needs and machine downtime, while linear accelerators have stringent power requirements and relatively long downtime [13]. Power infrastructure is a key factor in the choice between them [13].

    The limit. Reliability and power supply: a machine that is down treats nobody, and linacs depend more on power and maintenance than cobalt units [13].

    What could unlock it. Better power supply and service contracts move the limit; this is a matter of money and organisation, not physics (judgement).

  4. 4 Production Soft limit

    What it gives. Machines installed in shielded rooms, with trained staff, in enough places.

    The idea. Treatment with telecobalt equipment still serves a sizable share of patients in lower-income countries: up to 33% in countries like India, against only 7% in high-income ones [8]. A machine needs a shielded room, a licence and trained staff before it treats anyone (judgement).

    The limit. Supply is limited by the number of installed machines and trained teams, not by the factories alone (judgement).

    What could unlock it. A mix of cobalt and linac units lets a country add capacity where power and maintenance are weak [8][13] (judgement).

  5. 5 Economics Soft limit Binds most today

    What it gives. Enough funded centres, in reach of patients, to use the machines.

    The idea. A 2022 review gives India 675 teletherapy machines for 1.36 billion people, against 2,040 recommended [8]. An ICMR study reported in July 2025 counts 794 megavoltage machines against a minimum need of 1,450 for a projected 1.45 billion people in 2025 [11], about 0.55 machines per million (calculated).

    The limit. Capital cost, staff and where hospitals are sited: the shortfall is a funding and distribution gap, not a physical limit (judgement) [8][11].

    External radiotherapy machines per million people, India

    Today (2025): 0.55 machines per million · Limit: 4 machines per million · 14% of the way to the limit

    Typical national value: 794 megavoltage machines available for a projected 2025 population of 1.45 billion = 0.548 per million (calculated) [11]. The limit is the WHO optimal target of four per million on the same page, whose minimum is one per million [11]; the JCO review gives the same four per million as the IAEA ideal, with a minimum of 1.5 [8]. Source [11] is a news report of the ICMR study.

    What could unlock it. Public funding, shared centres and the cheaper, sturdier cobalt option are the usual levers in lower-income settings (judgement) [8][13].

  6. 6 Resources and rules Soft limit

    What it gives. Permission to site, build, commission and run a facility, and rules for the radioactive material.

    The idea. In India a licence covers siting, construction, commissioning, operation or decommissioning of a radiation facility [12], and applicants obtain it through the regulator's online system, e-LORA [12]. The policy choice between linac and cobalt units is made within this framework (judgement).

    The limit. Licensing steps and the regulation of radioactive sources add time and paperwork to each new centre [12] (judgement).

    What could unlock it. Online processing through e-LORA [12] is the route meant to shorten the paperwork (judgement).

as of 2026-11-25

Sources

  1. Modern Radiotherapy Technology: Obstacles and Opportunities to Access in Low- and Middle-Income Countries (15 July 2022) JCO Global Oncology 8, e2100376 (via PubMed Central), 2022
  2. 10.3 Radioactive Decay, University Physics Volume 3 (undated) OpenStax, 2026
  3. University Physics Volume 1, 17.3 Sound Intensity (spherical spreading, used here as the general inverse-square principle) OpenStax, 2016
  4. ICMR recommends interventions to meet gap in machines needed for cancer care (news report of an ICMR study in BMC Cancer, 24 July 2025) ThePrint, 2025
  5. Consenting process in radiation facilities (undated) Atomic Energy Regulatory Board, India, 2026
  6. Model for Estimating Power and Downtime Effects on Teletherapy Units in Low-Resource Settings Journal of Global Oncology (via PubMed Central), 2017