Material Insights · Understanding the Material World

Insulated power cable: Bill of materials

About these figures

Which unit, study and year the composition figures describe, and how they vary

Low voltage: NKT's 0.6/1 kV four-core 120 mm2 copper cable, 6.36 kg per m, 2023, per metre times 1,000 [1]. Medium voltage: Cabelte's 8.7/15 kV aluminium triplex cable, 2025: its composition table sums to 5,006.30 kg with exclusions (5,077.96 kg without) against a stated cable weight of 4,728.91 kg per km [2]. High voltage: weights only [3]. Prysmian's 132 kV declaration is per ampere and kilometre [4]. Joints and accessories are not included.

as of 2026-11-13

Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content

Variant 1 Low voltage
MaterialRoleAmount in one unitShare of the unit's mass
Cu CopperFunctional4830 kg75.9%
Copper 4.81 kg per m plus copper foil 0.02 kg per m, times 1,000 (calculated); share of the 6.36 kg per m total (calculated) [1].
PVC PVCStructural1080 kg17%
Polyvinyl chloride, 1.08 kg per m times 1,000 (calculated); the EPD gives 16.99%. Fillers of 450 kg per km (7.08%) are not specified and have no node [1].
Variant 2 Medium voltage
MaterialRoleAmount in one unitShare of the unit's mass
Al AluminiumFunctional2035.79 kg40.1%
Aluminium machine wire 9.50 mm, 2,035.79 kg in the composition table; the EPD gives 40% of the 5,077.96 kg composition total (40.1% calculated), which exceeds the stated cable weight of 4,728.91 kg per km [2].
LLDPE Polyethylene (LDPE, LLDPE)Structural1881.77 kg37.1%
Two polyethylene compounds, 1,019.28 kg (DOW HFDC 4202) and 862.49 kg (CAB 4805-UV), for the XLPE insulation and the sheath (sum calculated); share of the 5,077.96 kg composition total (calculated) [2].
Cu CopperFunctional750.79 kg14.8%
Copper machine wire 8 mm for the screen, 750.79 kg; the EPD gives 15% [2]. Two curing catalyst mixtures (204.79 and 133.16 kg, described as 70% ethylene and 30% propylene) have no node and are not counted.

as of 2026-11-13

How it is put together

The main steps from parts and materials to the finished unit

StepWhat happensSource
Draw and strand the conductorCopper or aluminium rod is drawn to wire and stranded to the cross-section needed.–
Extrude the insulationPVC or polyethylene compound is extruded over the conductor; XLPE is cross-linked with a curing agent.[1][2]
Add the screenCopper wires or foil are laid over the insulation as the screen.[1][2]
Apply sheath and armourAn outer sheath goes on, with steel armour for subsea cables.–
Test and wind on drumsLong lengths are tested and wound on drums for laying.–

as of 2026-11-13

Technologies inside it

The technologies inside the product, with how much of each per unit

Embodies

as of 2026-11-13

Sources

  1. Environmental product declaration: NYCWY 4x120 SM/70 (NEPD-4568-3821-EN) NKT A/S (made by NKT s.r.o., Kladno), registered with The Norwegian EPD Foundation, 2023, material composition and GWP-total tables; issued 14 June 2023
  2. Power Cable 72282140 - RHZ1-OL 8.7/15 3X1X240KAL+H25 (EPDITALY1100) Cabelte - Cabos Eléctricos, S.A., registered with EPDItaly, 2025, composition and climate change tables; declared unit one km of cable with a load of 1 A; issued 22 July 2025
  3. 525 kV HVDC Prysmian, indicative weights and cross-sections; the page shows no date
  4. Environmental Product Declaration: RHZ1-RA+2OL(S) 132KV 1X1200MAL+H120 (GlobalEPD EN 50693 011 rev2) Prysmian Cables Spain S.A., registered with GlobalEPD (AENOR CONFÍA), 2026, declared unit and reference service life; first issued 15 December 2023, revised 23 January 2026