Insulated power cable: Bill of materials
About these figures
Which unit, study and year the composition figures describe, and how they vary
Low voltage: NKT's 0.6/1 kV four-core 120 mm2 copper cable, 6.36 kg per m, 2023, per metre times 1,000 [1]. Medium voltage: Cabelte's 8.7/15 kV aluminium triplex cable, 2025: its composition table sums to 5,006.30 kg with exclusions (5,077.96 kg without) against a stated cable weight of 4,728.91 kg per km [2]. High voltage: weights only [3]. Prysmian's 132 kV declaration is per ampere and kilometre [4]. Joints and accessories are not included.
as of 2026-11-13
Direct materials
The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content
Variant 1 Low voltage| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| Cu Copper | Functional | 4830 kg | 75.9% |
| Copper 4.81 kg per m plus copper foil 0.02 kg per m, times 1,000 (calculated); share of the 6.36 kg per m total (calculated) [1]. | |||
| PVC PVC | Structural | 1080 kg | 17% |
| Polyvinyl chloride, 1.08 kg per m times 1,000 (calculated); the EPD gives 16.99%. Fillers of 450 kg per km (7.08%) are not specified and have no node [1]. | |||
| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| Al Aluminium | Functional | 2035.79 kg | 40.1% |
| Aluminium machine wire 9.50 mm, 2,035.79 kg in the composition table; the EPD gives 40% of the 5,077.96 kg composition total (40.1% calculated), which exceeds the stated cable weight of 4,728.91 kg per km [2]. | |||
| LLDPE Polyethylene (LDPE, LLDPE) | Structural | 1881.77 kg | 37.1% |
| Two polyethylene compounds, 1,019.28 kg (DOW HFDC 4202) and 862.49 kg (CAB 4805-UV), for the XLPE insulation and the sheath (sum calculated); share of the 5,077.96 kg composition total (calculated) [2]. | |||
| Cu Copper | Functional | 750.79 kg | 14.8% |
| Copper machine wire 8 mm for the screen, 750.79 kg; the EPD gives 15% [2]. Two curing catalyst mixtures (204.79 and 133.16 kg, described as 70% ethylene and 30% propylene) have no node and are not counted. | |||
as of 2026-11-13
How it is put together
The main steps from parts and materials to the finished unit
| Step | What happens | Source |
|---|---|---|
| Draw and strand the conductor | Copper or aluminium rod is drawn to wire and stranded to the cross-section needed. | – |
| Extrude the insulation | PVC or polyethylene compound is extruded over the conductor; XLPE is cross-linked with a curing agent. | [1][2] |
| Add the screen | Copper wires or foil are laid over the insulation as the screen. | [1][2] |
| Apply sheath and armour | An outer sheath goes on, with steel armour for subsea cables. | – |
| Test and wind on drums | Long lengths are tested and wound on drums for laying. | – |
as of 2026-11-13
Technologies inside it
The technologies inside the product, with how much of each per unit
Embodies- Cab Underground, submarine and superconducting cables 1 km The cable technology itself.
as of 2026-11-13
Sources
- Environmental product declaration: NYCWY 4x120 SM/70 (NEPD-4568-3821-EN) NKT A/S (made by NKT s.r.o., Kladno), registered with The Norwegian EPD Foundation, 2023, material composition and GWP-total tables; issued 14 June 2023
- Power Cable 72282140 - RHZ1-OL 8.7/15 3X1X240KAL+H25 (EPDITALY1100) Cabelte - Cabos Eléctricos, S.A., registered with EPDItaly, 2025, composition and climate change tables; declared unit one km of cable with a load of 1 A; issued 22 July 2025
- 525 kV HVDC Prysmian, indicative weights and cross-sections; the page shows no date
- Environmental Product Declaration: RHZ1-RA+2OL(S) 132KV 1X1200MAL+H120 (GlobalEPD EN 50693 011 rev2) Prysmian Cables Spain S.A., registered with GlobalEPD (AENOR CONFÍA), 2026, declared unit and reference service life; first issued 15 December 2023, revised 23 January 2026