Material Insights · Understanding the Material World

Solar inverter: Footprint

Raw materials in one unit

Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions

VariantMaterialAmount (kg)Emission factor (kg CO2e per kg)Emissions (kg CO2e)
StringAluminium29.614.8438.1
StringSteel7.61.9214.6

Worked out from data

The site's estimate

Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors

VariantStagePlaceEmissions (kg CO2e)Mass covered by factors
StringMakingWorld453100%
StringUseWorld27,480100%
StringMakingIndia453100%
StringUseIndia40,200100%

Worked out from data

Energy in use

Energy one unit uses per year of use, by carrier

Energy in use
  • El Electricity 2400 kWh per year · lifetime 25 years String Conversion loss, calculated with the declarations' method, rated power x hours x (1 - efficiency) [3]: 100 kW x 1,500 h x (1 - 0.984) = 2,400 kWh per year, using the European-weighted efficiency of the Huawei unit [1] and the hours and 25-year life of the Zucchetti declaration, the declared size closest to 100 kW [2]. At Sungrow's 2,000 hours it is 3,200 kWh per year [3].

as of 2026-11-17

Emissions by stage

Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant

StageValueUnitShareVariantPlaceYearSource
Making2140kg CO2e per Zucchetti Azzurro 80 kW inverter, manufacturing (the same for the 60 kW model)32.1StringItaly2025[2]
Logistics3.23kg CO2e per Zucchetti Azzurro 80 kW inverter, distribution0.05StringItaly2025[2]
Use4510kg CO2e per Zucchetti Azzurro 80 kW inverter over 25 years, use and maintenance (3,380 for the 60 kW model, 61.1% of its total)67.7StringItaly2025[2]
End of life33.4kg CO2e per Zucchetti Azzurro 80 kW inverter0.5StringItaly2025[2]
Use5640kg CO2e per 100 kW inverter over 25 years (calculated: the Zucchetti 80 kW figure x 100/80, at its 98.2% weighted efficiency and 1,500 hours)– StringItaly2025[2]
Making4260kg CO2e per Sungrow SG350HX (352 kVA), manufacturing, 21.5% of its total (calculated)– StringItaly2023[3]
Logistics28.5kg CO2e per Sungrow SG350HX, distribution, 0.1% of its total (calculated)– StringItaly2023[3]
Use15,500kg CO2e per Sungrow SG350HX over 25 years, use and maintenance, 78.3% of its total (calculated)– StringItaly2023[3]
End of life33.3kg CO2e per Sungrow SG350HX, 0.2% of its total (calculated)– StringItaly2023[3]

as of 2026-11-17. Shares are calculated against each declaration's published total (Zucchetti 6,660 kg for the 80 kW model and 5,530 kg for the 60 kW model; Sungrow 19,800 kg); the shares in the table are for the Zucchetti 80 kW model, the declared size closest to 100 kW. Installation (4.5 and 29.5 kg) is left out of the four stages. The use stage is the electricity lost in the inverter over 25 years; it scales with rated power (56.3 and 56.4 kg per kW for the 60 and 80 kW models, calculated), which supports the per-100 kW row, while making does not (2,140 kg for both models), so no per-100 kW making figure is given. Primary energy of manufacturing is 27,000 MJ non-renewable plus 3,060 MJ renewable for the Zucchetti models and 54,200 plus 6,530 MJ for the SG350HX. For the 100 kW Fronius Tauro ECO 100-D, the total is 4,247.8 kg CO2e over 20 years after a waste-management credit of 114.9 kg, more than a quarter of it from component production, with energy payback of 0.3 to 0.8 years [8].

End of life

What happens to a unit when it is thrown away: collection, reuse, recycling and disposal shares, by place

RouteSharePlaceYearSource
Metals (steel, aluminium, copper) recycled, in the declaration's scenario90Declaration scenario (not measured)2023[3]
Metals sent to landfill, in the declaration's scenario10Declaration scenario (not measured)2023[3]
Plastics recycled, in the declaration's scenario60Declaration scenario (not measured)2023[3]
Plastics incinerated, in the declaration's scenario40Declaration scenario (not measured)2023[3]
Circuit assemblies and cables recycled, in the declaration's scenario (10% incinerated, 25% landfill)65Declaration scenario (not measured)2023[3]
All e-waste documented as properly collected and recycled (not inverters only)22.3World2022[26]

as of 2026-11-17. No source opened measures collection or recycling of inverters; the first five rows are the modelled end-of-life scenario of one manufacturer.

Recovered as

The commodities and chemicals recovered at end of life, with recovery rates

Recovered as
  • Al Aluminium 90% recovered · Recycling Metals are modelled as 90% recycled [3]; aluminium is 42.0% of the mass of Sungrow's 352 kVA unit [3] and 31.78% of Zucchetti's 80 kW unit [2].
  • Cu Copper 90% recovered · Recycling Same modelled rate for metals [3]; copper is 15.9% of the Sungrow unit's mass [3].
  • St Steel 90% recovered · Recycling Same modelled rate for metals [3]; stainless and other ferrous alloys are 17.2% of the Sungrow unit's mass (calculated) [3].

as of 2026-11-17

End of life in India

Collection and recycling in India, including the informal sector

No source opened measures what happens to inverters at the end of life. A manufacturer's declaration models 90% of metals as recycled and the rest landfilled [3]. In India the E-Waste (Management) Rules 2022 apply from 1 April 2023, with a producer recycling target of 60%, rising to 80% by 2027-2028 [25]; the source names PV modules, not inverters. Informal recycling is not covered by the sources.

as of 2026-11-17

Water and waste

Water use and waste per unit where a source gives them

MeasureValueUnitStageYearSource
Materials sent for recycling at end of life16.4kg per inverterEnd of life2025[2]
Hazardous waste disposed at end of life3.25kg per inverterEnd of life2025[2]
Non-hazardous waste disposed at end of life18kg per inverterEnd of life2025[2]

as of 2026-11-17. End-of-life figures for the Zucchetti 60 and 80 kW inverters of about 53 kg; no water figures were found.

Sources

  1. SUN2000-100KTL-M2 technical specification (data sheet) Huawei Digital Power
  2. Environmental Product Declaration: Azzurro 3PH 60KTL-V3 and Azzurro 3PH 80KTL-V3 (EPDITALY1000) Zucchetti Centro Sistemi S.p.A. (EPDItaly programme), 2025
  3. Environmental Product Declaration: String Power Inverters SG350HX, SG285HX, SG320HX, SG333HX (EPDITALY0458) Sungrow Power Supply Co., Ltd., registered with EPDItaly, 2023
  4. E-Waste Management Rules, 2022 International Energy Agency policies database, 2022
  5. Global e-Waste Monitor 2024: Electronic Waste Rising Five Times Faster than Documented E-waste Recycling UNITAR, 2024