Material Insights · Understanding the Material World

Electricity

Energy carried by moving electric charge: made from almost every other source, sent through wires over great distances in an instant, and turned back into motion, heat, light and computation where it is used.

Energy carriers · No. 140

  • Energy carrier
Energy carriers · Foundation · Energy

Energy carried by moving electric charge: made from almost every other source, sent through wires over great distances in an instant, and turned back into motion, heat, light and computation where it is used.

Chart: Illustration: Electricity

Covered in What makes something a commodityCommoditiesFrom ground to marketCommoditiesPrices and cyclesCommoditiesThe chemical industry: what it makes and how it is organisedChemicalsHow a chemical process works: reactions, separations, catalysts and flowsheetsChemicalsThe economics of a chemical plant: costs, prices and profitChemicalsand 38 more
Go deeper pick a tab to open it in full

Technologies and products that use this

The 367 technologies and products whose tabs name Electricity, by what each one does with it. Open one for its full story.

Embodied in 10
  • Ar Aramid fibre Polymerisation, spinning and solvent recovery plants run on electricity and heat; no source gives a figure.
  • AI Artificial insemination of livestock Liquid nitrogen, in which the semen is stored, is made by cooling and separating air with electrically driven plants.
  • EmE Embodied energy trade Electricity is itself one of the six sectors under the EU border mechanism, and smelting puts large amounts into each tonne of aluminium.
  • Eye Eyeglasses Lens casting, grinding, polishing and coating machines run on electricity, so each pair carries a small amount of embodied energy.
  • Pil Hormonal contraception Chemical synthesis and tablet presses in pharmaceutical plants run on electricity.
  • Nd Neodymium magnets Separating rare earths and sintering the powder are energy-intensive steps, so each magnet embodies electricity and heat.
  • ORT Oral rehydration therapy Mixing, filling and sealing sachets in pharmaceutical plants use electricity, a small amount per sachet.
  • SS Stainless steel Brearley's first cast of 1913 was made in an electric furnace, and electric melting is the usual route.
  • Blt Three-point seat belt Weaving the webbing and pressing the steel parts uses electricity, so each belt carries a small amount of embodied energy.
  • Chl Water chlorination Chlorine is made by passing electricity through brine, so the disinfectant carries embodied electricity.
Energy to make 27
  • Agricultural tractor 16,250 MJ (calculated) · Manufacturing Assembly electricity is 13% of the production energy, put at about 50 MJ per kg of vehicle; for a 2,500 kg tractor that is 125,000 MJ, so about 16,250 MJ, calculated. The other carriers are not split
  • AI accelerator chip 22.4 kWh · Manufacturing Calculated, logic die only: 2.75 kWh/cm2 of fab energy for a 5 nm node in the ACT model x 8.14 cm2 for the 814 mm2 H100 die = 22.4 kWh (80.6 MJ), before yield losses, which ACT applies as a separate factor. TSMC's 4N is a derivative of the 5 nm N5 family. HBM, the interposer and packaging are not included: no source opened gives their energy, only carbon (see the stages note).
  • Aluminium can 0.043 kWh · Materials Average can Calculated: smelting electricity of 14.1 MWh per tonne (14.1 kWh per kg) of aluminium on the global average times the primary share, 26.6% of 11.58 g of metal, or 3.08 g. Excludes refining, rolling and can making; the 14.1 MWh figure has no stated year.
  • Corrugated box 0.101 kWh · Materials Bought electricity for the paper and pulp, calculated: (1.346 GJ per t of boxes in all minus 0.441 GJ per t at the corrugator plant) x 0.4 kg. Assumes the corrugator figure is part of the total.
  • Cotton T-shirt 0.926 kWh · Materials Yarn spinning: 15,500 MJ per 1,000 kg of garment x 0.215 kg = 3.33 MJ, at 3.6 MJ per kWh (calculated).
  • Display panel (LCD and OLED) 216 MJ · Manufacturing LCD and OLED (AUO plants) AUO used 0.26 GJ of energy per square metre of input sheet in 2025; the electricity part (purchased electricity plus self-used solar, 83% of AUO's 2025 energy use) is calculated as about 216 MJ. Per square metre of input glass, not of finished panel, and for panel making only, not the materials bought in.
  • Electric generator 347,400 MJ · Manufacturing Synchronous (ABB GBA 1120, 31 MW) 96,500 kWh of electricity to make the 31 MW machine, converted at 3.6 MJ per kWh (calculated).
  • EV charger 145.3 kWh · Manufacturing Electricity for making the 120 kW C6EU, about 523 MJ (calculated). The EPD prices it at 1.13 kg CO2e per kWh on the State Grid of China, which gives about 164 kg CO2e (calculated), the declared manufacturing core value. Materials-stage energy is not split out.
  • Flat glass sheet 39.3 MJ · Manufacturing Indicative: 25% of the same 157.1 MJ, Glass for Europe's general electricity share (calculated); primary energy, not delivered electricity (about 10.9 kWh)
  • Footwear 6.4 kWh · Manufacturing 6.4 kWh per pair (calculated): 23 GWh = 23,000,000 kWh of electricity over all buildings of the Chinese factory, divided by 3,600,000 pairs = 6.39 kWh per pair. The paper gives the 3.6 million pairs for August 2010 to January 2011 in the same data paragraph as the 23 GWh but does not state the period of the 23 GWh, so the figure assumes they match. Coal combustion caused about as much of the manufacturing burden as electricity; coal is not shown because no amount is given.
Show 17 more
  • Grain-oriented electrical steel 600 kWh · Manufacturing High-temperature anneal only, calculated: about 42,000 kWh on average to heat 70 tons of steel per cycle, so about 600 kWh per tonne, at Tata Steel's Cogent Orb Works in the UK, whose furnaces are heated by electric elements. Other steps and the steelmaking are not included. The full cradle-to-gate primary energy in the thyssenkrupp EPD is 51,400 MJ non-renewable plus 3,850 MJ renewable per tonne, with no split by carrier.
  • Integrated circuit (chip) 2.4 kWh · Manufacturing Fab electricity for one 32 MB DRAM chip in one 2002 study of one chip type (calculated: 1.5 kWh per cm2 of wafer x 1.6 cm2 of wafer per chip). ACT's later model parameters run from 0.90 kWh per cm2 at 28 nm to 2.75 kWh per cm2 at 3 nm.
  • Lead-acid battery 38.34 MJ · Manufacturing Standard Electricity in the battery factories per battery, Table 3-2 of the 2017 EU study.
  • Lithium-ion battery 30 MJ · range 8.5 to 11.4 MJ · Manufacturing NMC Electricity to make one kWh of cells on a 2 GWh-a-year line of a leading Chinese maker, including 4 MJ to charge the cells, in a 2019 study.
  • Memory chip 2.4 kWh · Manufacturing Wafer fabrication of one 32 MB DRAM chip of about 2000 (calculated: 1.5 kWh per cm2 x 1.6 cm2 of wafer). Modern chips and nodes differ: ACT lists 0.9 to 2.75 kWh per cm2 for logic nodes from 28 nm to 5 nm.
  • Paint and coatings 65.1 kWh per tonne · Manufacturing Calculated: 87.3 kWh per kilolitre at Asian Paints decorative plants in 2025-26 / 1.34 kg per litre, the density assumed in the NIST generic latex model; Indian paints may differ. Total energy at standalone Asian Paints was 1.09 GJ per kilolitre, about 810 MJ per tonne (calculated). Raw material energy is not given.
  • Permanent magnet 14 kWh · Manufacturing Sintered NdFeB Calculated: 8.4 kWh for sintering plus 5.6 kWh of other electricity per kg of coated magnet; excludes rare earth mining and separation.
  • PET bottle 0.002 kWh · Manufacturing Virgin PET bottle Calculated: preheating preforms takes 0.15 kWh per kg times 0.0129 kg. Injection moulding and blowing air are not included.
  • Printed circuit board 20 kWh · Manufacturing Rigid Assumed in a 2021 study for one m2 of four-layer FR-4 board, which estimates 18 to 25 kWh; studies it cites give from about 6 kWh (a panel of four-layer board) to 20 kWh.
  • Silicon wafer 272 kWh · Manufacturing Chip wafer Calculated: 0.385 kWh per cm2 of polished wafer times 706.9 cm2, the same as 2,127 kWh per kg times 0.128 kg. Cradle-to-gate, from Williams et al. data of 2002 that the 2013 study calls relatively old; a 2026 inventory still uses them, and no newer published per-wafer figure was found.
  • Solar PV cell 0.92 MJ · Materials Polysilicon (49 kWh per kg), Czochralski ingot (32 kWh per kg) and wafer sawing (4.92 kWh per m2) for one watt of cell, calculated from the 2020 inventory: 0.595 kg of crystal per m2 of wafer, 1.03 m2 of wafer per m2 of cell and about 214 W per m2 of cell. Older 170 micrometre wafers and 19.5% modules, so today's cells need less; weak
  • Solar PV module 130 MJ · Manufacturing Module assembly only: 14.0 kWh per square metre of panel times the EPD's 2.583 square metres (2278 x 1134 mm), calculated from the 2020 inventory of older modules. Wafer and cell energy is in the Solar PV cell node, traced through the component
  • Steel reinforcing bar 174 kWh · Manufacturing Blast furnace Oxygen furnace route electricity per tonne of steel, already within the 25.20 GJ
  • Transformer and power converter 10 million MJ · Manufacturing Power transformer (40 MVA, oil-immersed) 2,790,000 kWh of electricity to make an ABB 40 MVA unit, converted at 3.6 MJ per kWh (calculated); an old 2003 declaration for a different unit from the Matelec reference.
  • Variable speed drive 37.4 kWh · Manufacturing Calculated, rough: 1.01 kWh per kW of rated power in the 2008 declaration for a 7.5 kW ABB ACS350, times 37 kW. Factory energy only, not the energy in the materials. Scaling by rated power from a much smaller drive is uncertain, since smaller drives use more material per kW.
  • Vehicle transmission 15.5 kWh · Manufacturing Battery electric (single-speed) Electricity to manufacture the 20.2 kg transmission of the FITGEN e-axle (Table 4). Materials stage not given.
  • Wind turbine blade 89,300 kWh · Manufacturing Offshore (117 m IEA 15 MW baseline) Calculated in the design study from a factory utility cost of USD 7,145 per blade at USD 0.08 per kWh; the study does not name the carrier, shown here as electricity. Materials are not included.
Energy in use 37
  • AI accelerator chip 6868 kWh per year · lifetime 6 years Data-centre GPU Calculated: 700 W (H100 SXM design power) x 8,760 h x 0.80 (operational time LBNL assumes for training servers) x 1.4 (US average PUE in 2023) = 6,868 kWh a year at the meter; 4,906 kWh at the chip. At the 40% operational time for inference it is 3,434 kWh. With Uptime's 2023 industry average PUE of 1.58 the training case is 7,751 kWh. Lifetime is Google's six-year assumption for AI machines; the A100 study assumes three years.
  • Air conditioner 903 kWh per year · lifetime 7 years Inverter CSE average label figure of 902.8 kWh a year for 4-star variable speed split models on 1,600 hours (5-star about 740, 3-star 1,008.33); the article does not tie these averages to a size. Life is the LBNL assumption of about seven years for India. No source gives a comparable figure for a fixed speed unit.
  • Ceiling fan 144 kWh per year · lifetime 10 years Induction Calculated, illustrative, India: 75 W at top speed x 8 hours a day x 240 days (8 months) = 144 kWh a year, from CEEW's survey-based use pattern. Real fans run at lower speeds part of the time, so this is a ceiling; 1,350 hours a year gives 101 kWh and 3,694 hours (urban survey) 277 kWh. Life of 10 years is a study assumption.
  • Centrifugal water pump 4517 kWh per year · lifetime 10 years Calculated: 15,765 million kWh of farm electricity over 34.9 lakh electric pump sets in Maharashtra, 2011, figures Prayas takes from state regulatory orders and CEA; it is the average of all electric farm pumps, not of 5 hp sets, and Prayas finds farm consumption overestimated. The lifetime is the EU economic lifetime. EU base cases for comparison: 3,825 kWh a year for BC13 (28.9 kg) and 12,150 kWh for BC1 (52.9 kg), at 2,250 hours a year. A solar set draws no grid electricity
  • Cotton T-shirt 0.46 kWh per year · lifetime 3.2 years Worked estimate, calculated from the study's survey data. Washing: the shirt is 0.215 kg of a 4.04 kg load (5.3%); at 0.69 to 1.36 kWh per load that is 0.037 to 0.072 kWh per wash, and 18.2 washes give 0.67 to 1.32 kWh. Drying: an average dryer load is 9.10 lb (4.13 kg), so 0.215 kg is 5.2% of it; at 0.89 kWh per load (energy-efficient dryer) to 3.12 kWh per load (conventional) that is 0.046 to 0.163 kWh per dried shirt; 25.3% of 18.2 washes is 4.6 dryer runs, or 0.21 to 0.75 kWh. Total 0.88 to 2.07 kWh over 38.8 months (3.2 years), or 0.27 to 0.64 kWh per year; the figure shown is the midpoint. Gas dryers, detergent and water heating outside the machine are not included.
  • Data-centre server 1973 kWh per year · lifetime 4 years General-purpose Calculated: 7,892.8 kWh over 4 years for a Dell R760 at a light-medium workload. Dell's R740 gives 1,760.3 kWh a year and the JRC example server 1,661 kWh a year.
  • Display panel (LCD and OLED) 280 kWh per year · lifetime 4 years LCD monitor (27-inch) Calculated for the whole monitor: 16 W for 9.6 hours a day over 365 days is about 56 kWh a year (the report gives 224.9 kWh over 4 years), divided by the 0.2003 m2 viewable area. The study does not split use energy by part.
  • Electric bus 93,600 kWh per year (calculated) · lifetime 12 years 12 m city bus 1.3 kWh/km tender upper limit times 72,000 assured km a year; the Italian study used 1.25 kWh/km.
  • Electric generator 4.07 million kWh per year · lifetime 25 years Synchronous (ABB GBA 1120, 31 MW) Electricity lost as heat, not consumed fuel: the declaration gives 101,760,000 kWh of electrical energy in the usage phase, over 25 years (calculated per year). This matches 31,000 kW at 98.02% efficiency over 6,500 hours a year (about 626 kW lost). The generator's real input is shaft power from the turbine or engine.
  • Electric motor 254,500 kWh per year · lifetime 25 years Induction motor Calculated for the 37 kW IE3 motor at full load: 37 kW times 6,500 h a year divided by an efficiency of 94.5%.
Show 27 more
  • Electric water heater 172 kWh per year · lifetime 10 years Calculated, illustrative, India. A day of use is one 15-litre fill at 0.035 kWh per litre of 40 C water (European test condition, from about 10 C, so high for India) plus a standing loss of 0.419 kWh, the value declared by six of seven 15-litre models in a 2022 survey: 0.944 kWh. Over six months, as Maharashtra households heat bathing water, that is about 172 kWh a year; over two months, as in Uttar Pradesh, about 58 kWh; left on all year, about 345 kWh. The 10 years follow the usual Indian life.
  • EV charger 289.08 kWh per year · lifetime 20 years Fast Standby consumption only, for the 120 kW C6EU: 33 W all year, or 289.08 kWh. Left out: the electricity passed to cars, and the losses in converting and carrying it, which at the maker's claimed peak efficiency of 96% or more would be at least about 4% of each kWh drawn. The C7 draws 97 W by day and 150 W at night.
  • Goods vehicle 148,083 kWh per year (calculated) · lifetime 7 years Battery electric 113.91 kWh per 100 km over 130,000 km a year, calculated from the paper's two figures
  • Heat exchanger 7500 kWh per year · lifetime 30 years Gasketed Calculated, about: pump electricity to push liquid through one side of a 1 MW gasketed unit designed for 50 kPa. Alfa Laval's 2,000 kW HVAC cooling case needs 73,857 kWh of pump energy in one season of 5,520 hours at 25 m pump head; the unit's 50 kPa is about 5.1 m of that head, and halving for 1 MW gives about 7,500 kWh a year. The other side adds a similar amount if designed alike. The 30 years follow the lifetime assumed in a Swedish heat exchanger LCA.
  • Heat pump 2661.83 kWh per year · lifetime 15 years Air source (Vaillant 7 kW system with uniTOWER plus) Vaillant aroTHERM plus 7 kW system in the EPD scenario: 2,107.53 kWh for heating (SCOP 4.65, 1,400 hours, 7 kW design load) plus 554.3 kWh for cooling. The undated Mitsubishi EPD declares 97,019 kWh over 17 years for its 8.5 kW unit with a 200 L cylinder, heating and hot water, about 5,707 kWh a year (calculated); it also prints a COP of 2.6 at A7/W35 for that size, which does not fit its SCOP of 4.84 and is not used. No per-year figure was found for a ground source unit.
  • Industrial air compressor 528,500 kWh per year · lifetime 13 years Fixed-speed oil-injected screw Calculated: 75 kW of motor output divided by a motor efficiency of 0.9 is 83.3 kW of input; times 8,400 hours a year (top of the DOE base-load range) is 700,000 kWh at full load. The fact sheet's example machine runs 65% of the time loaded and 35% unloaded, drawing 30% of full power when unloaded, a load factor of 0.65 + 0.35 x 0.30 = 0.755. So 83.3 kW x 8,400 h x 0.755 = about 528,500 kWh a year; at 4,000 hours about 252,000 kWh. Over the 13-year lifetime of the US standard that is about 6.9 GWh.
  • Industrial boiler 52.5 million kWh per year · lifetime 25 years Electrode Calculated (no heating value basis applies to electricity). 187.2 TJ (52.0 GWh) divided by 99% efficiency = 52.5 GWh; at the IEA's 95 to 98% it is 53.1 to 54.7 GWh. On India's grid at 0.727 t CO2 per MWh (FY 2023-24, CEA weighted average including renewables) that is about 38,200 t CO2 a year (38,200 to 39,800 t), about 3.4 times the gas boiler.
  • Industrial robot 6913 kWh over 36,000 hours of continuous operation (study total, not per year) The study's own figures for one small collaborative arm (a UR5) doing a 6 s pick-and-place cycle with a 2 kg workpiece: 6,913 kWh after 36,000 h of continuous operation, with a constant draw of 100 W. The study gives no figure per year or lifetime in years. The duty is the study's, not an average for all robots.
  • Insulating glass unit -175 kWh per year · lifetime 30 years Argon low-e double (solar control, SHGC 0.27) Upper bound, calculated, India, against clear single glass. Step 1: solar factor of clear single glass 0.87 minus India's ECBC maximum SHGC of 0.27 for windows not facing north = 0.60. Step 2: most of India receives 4 to 7 kWh of sun per m2 a day; at the low end, 4 kWh/m2/day x 365 days = 1,460 kWh/m2 a year. Step 3: heat kept out = 0.60 x 1,460 kWh/m2 = 876 kWh of heat per m2 of glass a year. Step 4: divided by a seasonal efficiency (ISEER, kWh of cooling per kWh of electricity) of 5.00, the top of BEE's 2021 star range of 3.30 to 5.00 for split units: 876 / 5.00 = about 175 kWh of electricity per m2 a year. At 7 kWh/m2/day and ISEER 3.30 the same steps give about 465 kWh. Both overstate a real window's saving: the radiation figure is for flat ground, which gets more sun than a wall, and not all heat let in has to be removed by air conditioning. Negative means energy saved.
  • LED lamp 4.38 kWh per year · lifetime 8.5 years Calculated: 8 W (CorePro) times 1.5 hours a day times 365 days. The 1.5 hours is an assumption: the average daily use of residential LED lamps in the United States in 2020, from a 2012 DOE study. Real-world life is 7 to 10 years (TrendForce estimate); 8.5 years, the midpoint, is used for the total, so 31 to 44 kWh over life (calculated). At 1.5 hours a day the 15,000 hour rating would last 27 years. The Signify declarations give 88.5 kWh (5.9 W, 15,000 h) and 260 kWh (5.2 W, 50,000 h) over their lives.
  • Lift (elevator) 479 kWh per year · lifetime 25 years KONE MonoSpace 4 DX five-stop reference unit at usage category 2, ISO 25745-2 method; Otis Gen2 Life gives 504 kWh a year. A ten-storey lift would use more; not scaled.
  • Lithium-ion battery 64 kWh per year lost as heat (calculated) · lifetime 15 years LFP-based utility system Energy lost per kWh of capacity at one full cycle a day: 429 kWh in, 365 kWh delivered at 85% round-trip efficiency, calculated from; the charging electricity itself passes through to its users and is not counted as the battery's use.
  • Machine tool 131,610 kWh per year · lifetime 12 years Machining centre (on-mode) Table value: on-mode use of the modelled 4-axis machining centre, 30 kWh an hour for 4,387 hours a year. The study's assumptions, not a measured average.
  • Memory chip 0.22 kWh per year · lifetime 4 years DRAM Calculated: 0.3 W x 2 hours a day x 365 days is about 0.22 kWh a year; the study gives 0.88 kWh over 4 years of typical home use. Flash draws power only when read or written; no figure was found.
  • Motorcycle and scooter 410 kWh per year (calculated) · lifetime 12 years Battery electric 4.1 kWh per 100 km for the 2.9 kWh electric scooter in an Indian life-cycle study, over 10,000 km a year (calculated)
  • Passenger car 3382 kWh per year (calculated) · lifetime 15 years Battery electric 118.3 miles per gallon of petrol equivalent for the 300-mile midsize sedan on the 2020 US grid, over an average 11,873 miles a year, calculated with 33.7 kWh per gallon equivalent
  • Personal computer 17.8 kWh per year · lifetime 2 years Laptop Dell Latitude 7350 Detachable, typical energy consumption in the EU; the report itself assumes a 2-year lifetime, which is the tablet lifetime in Dell's white paper (4 years for notebooks).
  • Railway locomotive and coach 2.98 million kWh per year (calculated) · lifetime 30 years Electric locomotive 12.5 Wh per tonne-km for a 1,590 t train in Alstom's simulation between Calais and Arras, times 150,000 km a year (calculated). It assumes the whole year is run with that train, so treat it as indicative; it is the traction energy for the whole train the locomotive hauls.
  • Refrigerator 213.5 kWh per year · lifetime 10 years A label ceiling, not a measured average: the top of the 3-star band of the Indian frost-free label, 0.118 x 250 + 184 = 213.5 kWh a year (calculated), taking the adjusted volume as 250 litres; a real 250 litre double-door unit has a larger adjusted volume because freezer litres count 1.62 times. The 3-star band runs from 185.75 to 213.5 and 5-star is below 162.5 (formulas from VSC Times, a secondary page that cites no BEE notification). The 10 years is the life used by Lewandowska (10) and JEMA (10.4). Values in the studies: 287 kWh (Japanese catalogue mean, 501 litres), 303 kWh (calculated, 340 litres, class F) and 458.4 kWh (LG EPD).
  • Smart electricity meter 14.9 kWh per year · lifetime 10 years Single-phase Calculated: annual energy = average power x 8,760 hours. A Landis+Gyr E360 LTE single-phase meter draws under 1.7 W while communicating (typical), so at most 1.7 x 8,760 / 1,000 = 14.9 kWh a year; without communication under 0.65 W, 5.7 kWh a year. The IS 16444 idle ceiling of 5.0 W would be 43.8 kWh a year. The 10 years are the Indian tender life.
  • Smartphone 4.5 kWh per year · lifetime 3 years Average of 146 tested phones, range 3 to 7.7 kWh a year, from battery tests published in 2023; the 3 years follow the use period Apple and Fairphone assume.
  • Solar inverter 2400 kWh per year · lifetime 25 years String Conversion loss, calculated with the declarations' method, rated power x hours x (1 - efficiency): 100 kW x 1,500 h x (1 - 0.984) = 2,400 kWh per year, using the European-weighted efficiency of the Huawei unit and the hours and 25-year life of the Zucchetti declaration, the declared size closest to 100 kW. At Sungrow's 2,000 hours it is 3,200 kWh per year.
  • Solid-state drive 11.4 kWh per year · lifetime 5 years Client M.2 NVMe Calculated from Tannu and Nair's assumed average of 1.3 W in use all year: 1.3 W x 8,760 h = 11.4 kWh a year, 56.9 kWh over five years as in their Table 1. A lower estimate by this site, with an unsourced 2 h a day reading at 5.4 W and 22 h idle at 0.05 W on a Samsung 990 PRO, gives 11.9 Wh a day or about 4.3 kWh a year.
  • Television set 117 kWh per year · lifetime 7 years CLASP Mepsy model, India row of Table 2: business-as-usual unit energy consumption of 117 kWh a year for an average set, with a 7-year average lifetime; a modelled average, not a measurement.
  • Transformer and power converter 17,340 kWh per year · lifetime 35 years Distribution transformer (400 kVA, oil-immersed) Electricity lost as heat. Calculated from the declared losses at 70% load: (3.25 kW x 0.7 squared + 0.387 kW) x 8,760 hours.
  • Variable speed drive 3440 kWh per year · lifetime 10 years Standard drive Calculated losses of the drive alone, using the 98.1% efficiency and the use scenario (6,000 active hours a year at an average 80% load) of a 90 kW Danfoss drive: 29.6 kW (37 kW at 80% load) x (1/0.981 - 1) x 6,000 h = about 3,440 kWh. Standby is left out. It does not include the motor, whose use the drive is meant to cut.
  • Washing machine 156.9 kWh per year · lifetime 12.5 years Calculated: 0.713 kWh per cycle times 220 cycles a year for the 7 kg EU base case. Real use may be nearer 198 cycles a year. Another study uses 0.78 kWh per wash for 40 C and 60 C programmes. Indian machines are rated per kg: 5 stars needs 0.09 kWh/kg/cycle or less for front-load and 0.0132 for top-load and semi-automatic
Powers 242
Show 232 more
Converted by 38
Show 28 more
Stored by 17
Show 7 more
Lost by 5 Recovered by