Heat pump
A machine that heats a building by moving heat in from outside.
Appliances and lighting · No. 56
- Electrical and chemical age
Electricity is 92% to 98% of a heat pump's life-cycle emissions in two product declarations; making it is 2% to 7%.
Chart: Illustration: Heat pump
Where it comes from
Chart: Map of where it comes from
The first commercial heat pumps built only for heating date from 1938, when an Escher Wyss machine started up at Zurich City Hall after a 1937 offer of 27,850 Swiss francs. Switzerland had 35 by 1945; Canada had the first ground-coupled one in 1949.
Three things to know
- A 7 kW Vaillant outdoor unit weighs 139.4 kg and holds 0.9 kg of propane (R-290, GWP 0.02), while Mitsubishi's 8.5 kW unit holds 2.2 kg of R-32 (GWP 675).
- German field tests of 77 heat pumps in older buildings found average seasonal performance factors of 3.4 for air-to-water units and 4.3 for ground-coupled ones.
- From 1 January 2027 the EU restricts refrigerants with a GWP of 150 or more in self-contained heat pumps up to 12 kW.
The journey
- 1 MaterialsSteel 61%, copper 9% and aluminium 9% of a 139 kg outdoor unit
- 2 AssemblyPre-assembly, final assembly, helium leak test and refrigerant fill at Vaillant's plant in Nantes, France
- 3 InstallationAn outdoor unit plus an indoor hydraulic module feeding radiators or floor loops; about 8 kW for a house
- 4 UseAbout 2,660 kWh of electricity a year in the EPD scenario, over a 15-year reference life
- 5 End of lifeMetals assumed recycled at 70% to 95% in the declared scenarios; 65% of the refrigerant assumed recovered
Try this in What if Switch on levers and see what changes in India by 2036.
Covered in The laws of energy: conservation, entropy and efficiencyEnergyEarth's energy flows: sun, wind, water, heat and lifeEnergyPower density: why land and space matterEnergyMoving energy: wires, pipes and shipsEnergyUsing energy: food, materials, mobility and buildingsEnergyEfficiency, waste heat and recoveryEnergyand 2 more