Material Insights · Understanding the Material World

Heat pump: Bill of materials

About these figures

Which unit, study and year the composition figures describe, and how they vary

Air source rows are the Vaillant aroTHERM plus 7 kW outdoor unit (139.4 kg, EPD 387 of 2024) [1] and its 21.3 kg Hydraulic Station (EPD 274) [3], 160.7 kg (calculated). EPD 273 prints steel 50% and copper 21% for the outdoor unit, the Hydraulic Station's own table, so EPD 387 is used [4][2]. Ground source rows are a 10 kW dual-source prototype plus boreholes (2020) [6]. Mitsubishi's 8.5 kW unit with cylinder weighs 192 kg, 67 to 69% steel [5].

as of 2026-11-13

Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content

Variant 1 Air source (Vaillant 7 kW outdoor unit plus hydraulic station)
MaterialRoleAmount in one unitShare of the unit's mass
St SteelStructural95.68 kg59.5%
Casing, frame and tank of the outdoor unit and the hydraulic station. Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
Cu CopperFunctional17.02 kg10.6%
Refrigerant pipes, heat exchanger and windings. Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
Al AluminiumFunctional12.55 kg7.8%
Outdoor unit (9%); the hydraulic station lists none. Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
PET PET resinStructural5.58 kg3.5%
PET in the outdoor unit (4%). Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
Vm VermiculiteFunctional5.58 kg3.5%
Vermiculite in the outdoor unit (4%), probably sound or heat insulation; the EPD does not say what it is for. Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
ABS ABSStructural5.46 kg3.4%
Plastic parts, ABS. Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
PP PolypropyleneStructural3.64 kg2.3%
Plastic parts, PP. Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
PVC PVCStructural0.85 kg0.5%
PVC in the hydraulic station (4%). Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
PU Polyurethanes (MDI, TDI, polyols)Functional0.64 kg0.4%
PU in the hydraulic station (3%). Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
PS Polystyrene and EPSFunctional0.43 kg0.3%
EPS in the hydraulic station (2%). Declared percentage times declared weight (calculated): 139.4 kg aroTHERM plus 7 kW outdoor unit, EPD 387 Table 1 [1], plus 21.3 kg Hydraulic Station indoor module, EPD 274 [3]; 160.7 kg together.
Variant 2 Ground source (10 kW dual-source unit plus two 90 m boreholes, Italy)
MaterialRoleAmount in one unitShare of the unit's mass
St SteelStructural156.72 kg29.7%
128.85 kg of unalloyed and low alloyed steel in the 10 kW dual-source unit plus 27.87 kg of reinforcing steel in the borehole field (calculated sum) [6].
HDPE High-density polyethyleneStructural152 kg28.8%
Polyethylene of the two U-tube probes (32 mm outside diameter, 2 x 90 m) [6]. The study says only "polyethylene"; it is mapped to the high-density polyethylene node because borehole probe pipe is normally HDPE. This is an assumption, not the study's statement.
Al AluminiumFunctional47.16 kg8.9%
In the 10 kW dual-source unit, which can draw on outdoor air as well as the ground, so it is not a pure ground source machine [6].
Cu CopperFunctional39.17 kg7.4%
In the 10 kW dual-source unit [6].
Cem CementStructural27.86 kg5.3%
Grout of the boreholes [6]. Propylene glycol (86.13 kg), the 6.40 kg refrigerant charge (type not stated), 1.60 kg of lubricant and 4.20 kg of rubber, tin and other parts have no node and are not listed.
Kao Kaolin & claysStructural6.76 kg1.3%
Bentonite, a clay, in the borehole grout [6].

as of 2026-11-13

How it is put together

The main steps from parts and materials to the finished unit

StepWhat happensSource
Pre-assembly of modulesDedicated groups of parts are pre-assembled and passed to final assembly (Vaillant, Nantes, France)[4]
Final assembly IModules are joined into the unit[4]
Pressure and leak testHigh pressure test and helium leakage test of the refrigerant circuit[4]
Final assembly II and refrigerant fillThe remaining parts are fitted and the circuit is filled with refrigerant (0.9 kg of R-290 in the 7 kW unit)[4][1]
End-of-line testThe finished appliance is tested before it is packed[4]
Packaging and distributionPacked units go to central storage and then to installers; the EPD assumes components arrive 3,500 km by truck from Europe, or 1,000 km by truck and 19,000 km by ship from Asia[4]

as of 2026-11-13

Technologies inside it

The technologies inside the product, with how much of each per unit

Embodies
  • Mot Electric motors and drives 1 unit The Mitsubishi declaration lists a magnet (under 1% of contents) and lubricating oil, which suggests a permanent magnet motor in the compressor; the EPD does not name the motor type [5].
  • PE Transformers and power electronics 1 unit The hydraulic station contains a printed circuit board (2% of its mass) [3]; inverter drives are not itemised in the declarations.

as of 2026-11-13

Sources

  1. Environmental Product Declaration as per ISO 14025 and EN 15804: aroTHERM plus 7 kW & uniTOWER plus (EPD-Kiwa-EE-000387, issued 13.03.2024) Vaillant GmbH, Kiwa-Ecobility Experts, 2024, Tables 1, 2, 8, 12, 14
  2. Environmental Product Declaration: aroTHERM plus 5 kW & Hydraulic Station (EPD-Kiwa-EE-000270, issued 13.03.2024) Vaillant GmbH, Kiwa-Ecobility Experts, 2024, Tables 1, 2, 10, 14
  3. Environmental Product Declaration as per ISO 14025 and EN 15804: Hydraulic Station, also known as VWZ MEH 97/6 (EPD-Kiwa-EE-274-EN, issued 13.09.2023) Vaillant GmbH, Kiwa-Ecobility Experts, 2023, Table 1 and product weight
  4. Environmental Product Declaration: Vaillant aroTHERM plus 7 kW (EPD-Kiwa-EE-273, issued 13.09.2023) Vaillant GmbH, Kiwa-Ecobility Experts, 2023, Sections 2.4 and 3.3, Table 2 (Table 1 repeats the Hydraulic Station composition and is not used)
  5. Environmental Product Declaration to EN 15804 (BRE Global programme): Mitsubishi Electric air source heat pumps of 5, 6, 8.5, 11.2 and 14 kW with EHPT20X-MHEDW 200 L packaged cylinder (undated; manufacturing data 1 April 2021 to 31 March 2022) Mitsubishi Electric, BRE Global, Technical information, Main Product Contents, LCA results for PUZ-WM85VAA, scenarios
  6. Data on the environmental performance analysis of a dual-source heat pump system Data in Brief 31, article 105919 (Marinelli, Butturi, Lolli, Rimini, Gamberini), 2020, Tables 1 to 3