Material Insights · Understanding the Material World

Heat pump: Working

What it is

The product and the job it does, in a short paragraph

A heat pump heats a building by moving heat from outdoor air or the ground indoors, using electricity to drive a compressor. This node covers complete units sold under HS 8418.61. The functional unit is one air-to-water heat pump of about 8 kW heat output, a size for a house: the average air source heat pump fitted under the English and Welsh Boiler Upgrade Scheme in late 2025 was 8.4 kW [22]. The sources used here cover 7 to 10 kW. Air-conditioning-only machines are left out.

as of 2026-11-13

How it works

How it does its job, step by step in plain words

A refrigerant circulates in a closed loop [4]. In the evaporator it boils at low pressure and takes heat from the outdoor air, or from brine in ground pipes. A compressor squeezes the vapour so that it is hotter than the heating water. In the condenser the vapour turns back to liquid and hands its heat to the water that feeds radiators or floor loops, and an expansion valve lowers the pressure so the loop can start again. Most of the heat delivered comes from outside, so the machine returns several units of heat for each unit of electricity: seasonal coefficients of performance (SCOP) of 4.65 for a 7 kW unit [1] and 4.84 for an 8.5 kW unit at 35 °C water, falling to 3.48 at 55 °C [5]. Factory tests include a helium leak test [4].

as of 2026-11-13

Key specifications

The numbers that describe it, each with unit, variant, year and source

SpecValueUnitVariantYearSource
Design heat output, aroTHERM plus (Vaillant)7kWAir source2024[1]
Heat output, PUZ-WM85VAA (Mitsubishi Electric Ecodan, undated EPD with 2021 to 2022 data)8.5kWAir source– [5]
Outdoor unit mass without packaging, aroTHERM plus 7 kW139.4kgAir source2023[4]
Refrigerant charge, aroTHERM plus 7 kW (R-290 propane)0.9kgAir source2024[1]
Refrigerant charge, Ecodan 8.5 kW (R-32)2.2kgAir source– [5]
Seasonal coefficient of performance (SCOP), aroTHERM plus 7 kW system as declared in its EPD4.65ratioAir source2024[1]
SCOP at 35 °C flow, Ecodan 8.5 kW4.84ratioAir source– [5]
SCOP at 55 °C flow, Ecodan 8.5 kW3.48ratioAir source– [5]
Seasonal performance factor measured in 77 older buildings, air-to-water (61 outside-air units)3.4ratioAir source2025[7]
Seasonal performance factor measured in 77 older buildings, ground-coupled (16 units)4.3ratioGround source2025[7]

as of 2026-11-13

Variants

The variants whose make-up or footprint differs a lot, what defines each and its share of units

VariantDefining specYearSource
Air sourceTakes heat from outdoor air; in the 7 kW Vaillant reference the outdoor unit weighs 139.4 kg and holds 0.9 kg of R-290; field SPF 3.4 in German older buildings. No unit share found for air-to-water alone: in 19 European countries in 2024, 668,000 heating-only air-to-water and 875,000 reversible air-to-air heat pumps were sold2025[12][1][7]
Ground sourceTakes heat from boreholes or ground loops; field SPF 4.3. The only kilogram inventory found is a 10 kW dual-source unit (it can use either outdoor air or the ground) of 227.4 kg with two 90 m boreholes holding 300.6 kg of field materials (calculated sums, Bologna, Italy, 2020); no share of units found2020[6][7]

as of 2026-11-13

Limits

The physical limits set by science and the engineering limits of today's design, with today's value

LimitKindLimitTodayUnitSource
Carnot limit on the heating coefficient of performance, 7 °C source and 35 °C delivery (calculated as T hot / (T hot minus T cold) in kelvin: 308.15 / 28)Physical114.84ratio (today's value is a seasonal figure at 35 °C, so the comparison is indicative)[5]
Efficiency penalty of a hotter flow: SCOP at 55 °C against 35 °C for an 8.5 kW unitEngineering4.843.48SCOP[5]
Gap between rated and measured performance: 4.65 declared SCOP of a 7 kW system against 3.4 average SPF of air-to-water units in older German buildings (different conditions)Engineering4.653.4ratio[1][7]

as of 2026-11-13

Science it relies on

The science principles it works by or is limited by

Limited by
  • Carnot's limit on heat engines The ratio of heat moved to work done cannot exceed the Carnot value set by the temperatures of the source and the delivered heat.
  • Heat conduction (Fourier's law) Heat has to cross the walls of the two heat exchangers, which sets their size and the temperature gap between refrigerant and air or water.
Relies on

as of 2026-11-13

Sources

  1. Environmental Product Declaration as per ISO 14025 and EN 15804: aroTHERM plus 7 kW & uniTOWER plus (EPD-Kiwa-EE-000387, issued 13.03.2024) Vaillant GmbH, Kiwa-Ecobility Experts, 2024, Tables 1, 2, 8, 12, 14
  2. Environmental Product Declaration: Vaillant aroTHERM plus 7 kW (EPD-Kiwa-EE-273, issued 13.09.2023) Vaillant GmbH, Kiwa-Ecobility Experts, 2023, Sections 2.4 and 3.3, Table 2 (Table 1 repeats the Hydraulic Station composition and is not used)
  3. Environmental Product Declaration to EN 15804 (BRE Global programme): Mitsubishi Electric air source heat pumps of 5, 6, 8.5, 11.2 and 14 kW with EHPT20X-MHEDW 200 L packaged cylinder (undated; manufacturing data 1 April 2021 to 31 March 2022) Mitsubishi Electric, BRE Global, Technical information, Main Product Contents, LCA results for PUZ-WM85VAA, scenarios
  4. Data on the environmental performance analysis of a dual-source heat pump system Data in Brief 31, article 105919 (Marinelli, Butturi, Lolli, Rimini, Gamberini), 2020, Tables 1 to 3
  5. Fraunhofer ISE research project completed: heat pumps provide climate-friendly heating in existing buildings Fraunhofer ISE, 2025
  6. European Heat Pump Market and Statistics Report 2025: Executive summary European Heat Pump Association, 2025
  7. Air source heat pump costs and savings - Which? Which? (UK consumer organisation), Karen Lawrence, 14 April 2026, 2026