Material Insights · Understanding the Material World

Heat exchangers and pinch integration: Energy footprint

Energy in use

The energy it uses or converts while it works, and how efficiently

Consumption
None directly; pumps or fans move the streams through the exchanger
Conversion
Moves heat from a hot stream to a cold one
Efficiency
50
Unit
% furnace efficiency gain at best, from combustion air preheat [4]
Note
Cooling flue gas from 300°F to 140°F gives about a 3% efficiency gain [4]. Process integration projects typically pay back in 1 to 3 years [6].

as of 2026-11-12

Energy links

The energy sources and technologies it uses, holds, converts, loses or gets back

Recovers
  • Ht Heat Takes heat that would be lost, which the DOE study puts at 20 to 50% of industrial energy input [4].

as of 2026-11-12

Sources

  1. Waste Heat Recovery: Technology and Opportunities in U.S. Industry (BCS Inc. for US DOE Industrial Technologies Program) US Department of Energy, 2008
  2. Process integration (pinch analysis) Natural Resources Canada, 2025