Material Insights · Understanding the Material World

Heat

Energy carried by the jostling of atoms and molecules: released by burning fuels, nuclear reactions and sunlight, moved through steam, water and air, and used for warmth, cooking and industrial processes.

Energy carriers · No. 141

  • Energy carrier
Energy carriers · Foundation · Energy

Energy carried by the jostling of atoms and molecules: released by burning fuels, nuclear reactions and sunlight, moved through steam, water and air, and used for warmth, cooking and industrial processes.

Chart: Illustration: Heat

Go deeper pick a tab to open it in full

Technologies and products that use this

The 200 technologies and products whose tabs name Heat, by what each one does with it. Open one for its full story.

Embodied in 14
Show 4 more
Energy to make 18
  • Aluminium can 1.18 MJ · Materials Average can Calculated: cradle-to-gate primary energy of 1,320 MJ per 1,000 North American cans of 13.46 kg, all carriers, from ore to finished can, scaled to a 12 g can. It includes the smelting electricity above, so the two rows must not be added. Cradle to grave, including end-of-life processing and the debit for replacement metal, the study gives 1,630 MJ per 1,000 cans, about 1.45 MJ per 330 ml can (calculated).
  • Corrugated box 1.81 MJ · Materials Fossil fuels, 4.515 GJ per t x 0.4 kg (calculated). FEFCO does not split them by fuel; across all European pulp and paper mills, gas was 29.2% of fuel and coal 1.3% in 2024. Includes steam for the corrugator, not split out.
  • Electric generator 264,600 MJ · Manufacturing Synchronous (ABB GBA 1120, 31 MW) 73,500 kWh of heat, converted at 3.6 MJ per kWh (calculated); the declaration's table columns are not clearly aligned.
  • Glass container 1.38 MJ · Manufacturing Low-cullet batch Calculated: EU container glass averages 5.8 GJ per tonne, taken as the level at the European average cullet of 52%; each 10 points of cullet changes furnace energy by 2.5%. At 20% cullet: plus 32 points x 2.5% / 10 points = 8% more, so 5.8 GJ/t x 1.08 = 6.26 GJ/t (= MJ/kg) x 0.220 kg = 1.38 MJ per bottle. JRC does not say whether 5.8 GJ/t is melting only; forming, annealing and compressed air are probably not included.
  • Insulating glass unit 624 MJ · Manufacturing Argon low-e double Calculated: renewable 45.6 plus non-renewable 578 MJ primary energy per m2, cradle to gate (A1 to A3). The EPD gives primary energy, not fuel and electricity separately.
  • Lithium-ion battery 140 MJ · Manufacturing NMC Steam per kWh of cells on the same line. With electricity this is 170 MJ, about 47 kWh (calculated). A 2023 Nature Energy study puts today's cell-making energy at 20 to 40 kWh (72 to 144 MJ, calculated) per kWh, by battery type and excluding materials; the 2019 figure for one line sits above that range, mostly because of steam.
  • Memory chip 1.6 MJ · Manufacturing Fossil fuels burnt on site for the same chip (calculated: 1 MJ per cm2 x 1.6 cm2).
  • Mineral wool insulation 114 MJ · Manufacturing Stone wool Midpoint of 76 to 153 MJ per m2 at 100 mm (calculated): 7 to 14 GJ per tonne for stone and slag wool times 10.9 kg. Fuels are coke and gas in cupolas, or electricity.
  • PET bottle 0.99 MJ · Materials Virgin PET bottle Calculated: 70 to 83 MJ per kg of PET resin, taken at 76.5 and multiplied by the 0.0129 kg body. Primary energy of all carriers; Shen et al, citing PlasticsEurope, give 68.6 MJ per kg for bottle-grade PET.
  • Plastic foam insulation board 311 MJ · Materials EPS Calculated: total primary energy A1 to A3 of the 24 kg/m3 declaration, 44.4 MJ renewable (TPE) plus 67.7 MJ non-renewable (TRPE) = 112.1 MJ per m2 at R = 1 (36 mm), times 100/36 gives about 311 MJ (about 86 kWh) per m2 at 100 mm. It includes the energy content of the plastic itself.
Show 8 more
  • Printed circuit board 105 kWh · Manufacturing Rigid six-layer Heat in the same ecoinvent six-layer entry.
  • Silicon wafer 0.16 kWh · Manufacturing Solar wafer Per M10 wafer, calculated: 8 kWh of thermal energy per kg of solar-grade silicon times 0.0201 kg.
  • Solar PV cell 0.08 MJ · Materials Heat for polysilicon, 28.8 MJ per kg, calculated per watt as above
  • Steel reinforcing bar 25,200 MJ · Manufacturing Blast furnace Specific energy consumption of Indian BF-BOF TMT rebar, 25.20 GJ per tonne, all carriers (RMI Exhibit 14, 2024 values); converted to MJ (calculated). Tata Steel's EPD gives 26,500 MJ of non-renewable primary energy (energy carriers) cradle to gate
  • Transformer and power converter 170,640 MJ · Manufacturing Power transformer (40 MVA, oil-immersed) 47,400 kWh of heat, converted at 3.6 MJ per kWh (calculated).
  • Variable speed drive 20.7 kWh · Manufacturing Calculated, rough: 0.56 kWh per kW of rated power in the same 7.5 kW ABB declaration, times 37 kW.
  • Vehicle transmission 164 MJ · Manufacturing Battery electric (single-speed) Heat to manufacture the same transmission (Table 4).
  • Wind turbine tower 7.35 million MJ · Materials Tubular steel Calculated: 351 tonnes of steel times the 2024 global average of 20.95 GJ per tonne of crude steel, about 7,350 GJ (about 2,040 MWh). The range runs from 3,450 GJ for scrap-based arc furnace steel (9.84 GJ/t) to 8,380 GJ for blast furnace steel (23.88 GJ/t). It covers crude steel only, not rolling, welding or coating, and mixes coal, gas and electricity, so it sits under heat.
Energy in use
  • Insulating glass unit -223 kWh per year · lifetime 30 years Air-filled double Upper bound, calculated: heat saved per m2 against single glass, EU average climate: (5.8 minus 2.9) W/m2K x 3,199 heating degree days (K day, base 18 degrees Celsius, EU average of 42 years of data) x 24 h = 223 kWh. It ignores solar gain and frames, and centre-of-glass U-values are better than whole windows.
  • Mineral wool insulation -243 kWh per year · lifetime 50 years Calculated, 100 mm stone wool on an uninsulated solid wall: (1) R added = 0.100 m / 0.036 W/(m K) = 2.78 m2K/W; (2) baseline U0 = 2.1 W/m2K, the typical UK solid wall value, so R0 = 1/2.1 = 0.476 m2K/W; (3) U1 = 1 / (0.476 + 2.78) m2K/W = 0.307 W/m2K; (4) saving 2.1 minus 0.307 = 1.79 W/m2K; (5) 1.79 W/m2K x 5,656 K day per year (Finland's 1979 to 2022 average heating degree days, base 18 degrees Celsius) x 24 h per day = 243,000 Wh = about 243 kWh per m2 per year; about 12,200 kWh over 50 years. Negative means energy saved.
  • Plastic foam insulation board -243 kWh per year · lifetime 50 years EPS Calculated for 100 mm on an uninsulated solid wall in Finland: R added = 0.100 / 0.036 = 2.78 m2K/W; baseline U0 = 2.1 W/m2K, the value assumed for UK solid walls, so R0 = 0.476; U1 = 1/(0.476 + 2.78) = 0.307; saving 1.79 W/m2K times 5,656 K day per year times 24 h = about 243 kWh per m2 a year. Negative means heat saved.
Powers 56
Show 46 more
Converted by 22
Show 12 more
Stored by 7 Lost by 72
Show 62 more
Recovered by 14
Show 4 more