Plastic foam insulation board
Rigid boards of polystyrene or polyurethane foam that slow heat flow through walls and roofs.
Buildings and construction · No. 93
- Electronic age
One maker's XPS board fell from 57.8 to 9.77 kg CO2e per m2 at the same insulation by changing its blowing agent.
Chart: Illustration: Plastic foam insulation board
Where it comes from
Chart: Map of where it comes from
Ray McIntire made foam polystyrene at Dow in 1941. BASF first produced Styropor in 1951. Saint-Gobain was making rigid polyurethane foam for insulation by 1957, and the polyisocyanurate (PIR) form was introduced in 1967.
Three things to know
- EPS is about 98% air and 2% plastic, so 100 mm of a 24 kg/m3 board holds only about 2.4 kg of material per m2 (calculated).
- Switching XPS from the blowing agent HFC-134a, with a warming potential about 1,430 times that of CO2, cut Owens Corning's declared footprint by more than 80%.
- India ended HCFC-141b use in foam in 2020, and its Kigali schedule starts with a 10% HFC cut in 2032 and reaches 85% in 2047.
The journey
- 1 Oil and gasStyrene from benzene and ethylene for EPS and XPS; MDI and polyols for PIR and PUR
- 2 Polymer and blowing agentPolystyrene beads or granules with pentane or another gas; liquid MDI and polyol with pentane
- 3 FoamingBeads expanded with steam and moulded (EPS), melt extruded through a die (XPS), or foamed between facings (PIR)
- 4 BoardCooled, trimmed and cut to size, in grades about 24 to 30 kg/m3
- 5 In the buildingWalls, roofs, floors and cold stores for as long as the building stands
- 6 End of lifeDeclared as incineration in Europe and landfill in North America; little recycling
Try this in What if Switch on levers and see what changes in India by 2036.