Material Insights · Understanding the Material World

Heat pumps, air conditioning and refrigeration: Levers

Held back most by

Resources and rules

Physics leaves room: a Carnot heat pump moving heat up 20 °C could deliver about 14.65 units for each unit of work [13]. What binds in India is the rulebook for cooling: room ACs added 10 to 15 million a year could reach over 120 GW of peak demand by 2030, while the minimum standard improves only 2 to 3% a year [15].

The six layers

Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it

Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A hard limit comes from mathematics or nature and can only be sidestepped; a soft limit moves with effort, scale, money or policy.

  1. 1 Mathematics Hard limit

    Mathematics is the language of its physics

    What it gives. The bookkeeping of heat moved against work spent.

    The idea. A physical law makes the machine work and mathematics sizes it, so the role is language. The coefficient of performance of a heat pump is the heat delivered to the warm side divided by the work put in, which is heat delivered over heat delivered minus heat taken from the cold side [13].

    The limit. The sums only count heat in and out; they cannot say how large the ratio may be, which the next layer sets [13].

    What could unlock it. Seasonal measurements, such as OpenEnergyMonitor's, turn the same ratio into a yearly figure for real homes [14].

    Show the maths KP = Qh ÷ (Qh - Qc)
    KP
    the coefficient of performance of a heat pump: heat delivered for each unit of work
    Qh
    the heat given to the warm side in one cycle, in kJ
    Qc
    the heat taken from the cold side in one cycle, in kJ

    In plain words. The machine takes some heat from the cold side and adds the work it is given. All of that arrives on the warm side. So the work is the difference between the two heats. Divide the heat you wanted by the work you paid for and you have the score.

    Worked example. Qh = 30 kJ, the source's example [13]. The work it needs is 30 × (293 - 273) ÷ 293 = 2.05 kJ, which the source rounds to 2 kJ [13], so Qc = 30 - 2.05 = 27.95 kJ (calculated). KP = 30 ÷ (30 - 27.95) = 14.6 (calculated), the same as the Carnot ratio in the next layer.

  2. 2 Science Hard limit

    What it gives. The second law of thermodynamics: heat does not flow from cold to warm unless work pushes it.

    The idea. The best ratio of heat delivered to work depends only on the two temperatures, measured from absolute zero, and it falls as the lift between them grows [13]. A Carnot heat pump working between 0 °C outside and 20 °C inside delivers 293 ÷ 20 = 14.65 units of heat for each unit of work (calculated) [13].

    The limit. No machine can beat the Carnot ratio, the warm temperature divided by the gap between warm and cold temperatures, in kelvin [13].

    What could unlock it. The only free choices are a smaller temperature lift (a warmer source, a lower delivery temperature) or a better source; ground-source and industrial heat pumps use a warmer source than winter air.

    GSH Geothermal direct use and ground-source heat pumpsMVR Industrial heat pumps and vapour recompression

    Show the maths KP = Th ÷ (Th - Tc)
    KP
    the best heat delivered for each unit of work, a ratio
    Th
    the warm side temperature, in kelvin (degrees Celsius plus 273)
    Tc
    the cold side temperature, in kelvin (degrees Celsius plus 273)

    In plain words. Pumping heat up a small hill takes little work and up a big hill takes a lot. The hill is the gap between the cold and warm temperatures. The smaller the gap, the more heat you move for each unit of work.

    Worked example. Th = 293 K (20 °C inside) and Tc = 273 K (0 °C outside), the source's example [13]. KP = 293 ÷ (293 - 273) = 14.65 (calculated). The source's own working gives 2 kJ of work for 30 kJ of heat [13]. A real unit does worse because of losses and the hotter delivery it needs; this is not compared with measurements here.

  3. 3 Engineering Soft limit

    What it gives. A compressor, two coils, an expansion valve and a refrigerant that run quietly for years.

    The idea. In OpenEnergyMonitor's public dashboard, 213 fully metered systems with a full year of data (November 2024 to November 2025) had a seasonal performance factor of 3.83 [14]. The site says over 600 systems upload data; it is a community initiative to share and compare data, and the only country the page names is the UK, so it is not a random sample of the world's heat pumps [14]. Most Indian room ACs use HFC-32 or HFC-410A [17].

    The limit. Compressor losses and the temperature step needed across each coil keep real units well below the Carnot ratio.

    What could unlock it. Better refrigerants and compressors raise the ratio; the figures in this layer do not cover India's own cooling units, whose efficiency is on the ISEER scale, where the best on the market is 6.3 [15].

  4. 4 Production Soft limit

    What it gives. Millions of compressors, coils and cabinets at low cost.

    The idea. India adds 10 to 15 million new ACs a year [15]. The IEA says 40% of the heat pumps sold worldwide in 2023 were made in China, which had 50% of global heat pump exports [16].

    The limit. Making units is not the bottleneck: the IEA says China's air conditioning factories are mostly not running at full capacity, with as much as 40% unused, and could switch lines to heat pumps quickly [16].

    What could unlock it. India's volume of ACs already gives a base of factories and suppliers [15].

  5. 5 Economics Soft limit

    What it gives. A price a household will pay, and savings on bills that repay it.

    The idea. The median 1-ton AC with an ISEER of 5 costs Rs 5,970 more than a median unit of 3.5 [15]. The paper says the net benefit to consumers would be at least Rs 66,000 crore in its conservative case [15]. Typical 2-star and 3-star ACs are the market average, so most buyers choose the lower upfront price [15].

    The limit. The buyer pays the upfront price and the bill comes later, spread over the years the unit lasts.

    What could unlock it. Standards and labels move the average sale up without asking every buyer to pay more attention [15].

    Show the maths A = r ÷ (1 - (1 + r)-n) × P
    A
    the yearly charge that repays the extra price, in rupees
    r
    the yearly cost of capital, as a fraction
    n
    the years over which the cost is repaid
    P
    the extra price paid at purchase, in rupees

    In plain words. An efficient AC costs more on the day you buy it. The first part works out how much you must set aside each year, with interest, to repay that extra cost. If the yearly saving on the electricity bill is bigger, buying the better unit pays.

    Worked example. P = Rs 5,970 [15]; r = 12% and n = 10 years (both assumed). The repayment factor is 0.177, so A = 0.177 × 5,970 = Rs 1,057 a year (calculated) [18]. The source does not give a yearly bill saving per unit, so no payback is stated here.

  6. 6 Resources and rules Soft limit Binds most today

    What it gives. Standards, refrigerant rules and a grid that can carry the cooling load.

    The idea. The paper says room ACs caused an estimated 40 to 45 GW of the evening peak in the May 2024 heatwave, could be over 120 GW by 2030 and 180 GW by 2035, and India may add 130 million room ACs between 2025 and 2035 [15]. The 1-star label is the de facto minimum standard and has improved 2 to 3% a year; a faster 8% a year path could cut peak demand by over 60 GW by 2035 [15]. India's HFC phase-down starts with a freeze in 2028, a 10% cut by 2032 and an 85% cut by 2047 [17].

    The limit. The minimum standard and the refrigerant schedule decide what can be sold, and the evening peak decides what the grid must build [15][17].

    What could unlock it. Faster standards and refrigerant transitions are policy choices, not physics [15][17].

    Pas Passive solar and natural coolingDHN District heating and cooling networks

as of 2026-11-23

Sources

  1. The Carnot Cycle (University Physics Volume 2, section 4.5) OpenStax, 2016
  2. HeatpumpMonitor.org Introduction OpenEnergyMonitor, 2025
  3. India Can Avert Power Shortages and Cut Consumer Bills with Stronger AC Efficiency Standards (working paper) India Energy and Climate Center, UC Berkeley, 2025
  4. Is a turnaround in sight for heat pump markets? International Energy Agency, 2025
  5. Paving India's Pathway to HFC Phasedown: The Emerging Issue of PFAS Pollution and Learning from the Global Developments Council on Energy, Environment and Water, 2026
  6. Equations and Variables in the ATB (2024) NREL, 2024