Material Insights · Understanding the Material World

Latent heat and cold storage: Materials

Materials it needs

The commodities and chemicals it needs per unit, its share of each one's demand and how critical each is

Needs
  • H₂O Water criticality low Ice stores freeze water at night to cool buildings by day [5].
Made of
  • FA Fatty acids criticality low Fatty acids are one class of low-cost phase change material, with latent heats of 125 to 250 J/g [3].

as of 2026-11-12. No source opened gives amounts per kWh stored. Criticality is the writer's judgement: water and the common salts and waxes used are widely available.

Critical materials

The materials whose supply could hold it back

  • No scarce material limits latent storage: ice stores need only water [5], and low-cost salt hydrates store heat for 0.90 to 40 dollars per kWh [3].
  • The limits are in the materials' behaviour: salt hydrates supercool by more than 5 °C, melt unevenly and corrode containers [3].

as of 2026-11-12

Sources

  1. Review of Low-Cost Organic and Inorganic Phase Change Materials with Phase Change Temperature between 0°C and 65°C (Hirschey, Kumar, Turnaoglu, Gluesenkamp and Graham) Oak Ridge National Laboratory and Georgia Institute of Technology, 6th International High Performance Buildings Conference at Purdue (on OSTI), 2021
  2. Energy storage case study: ice thermal storage in a 53-storey Manhattan office building (ES-newwater-cs) NYSERDA, 2018