Seismic base isolation: Overview
What it does
The job the technology does for people, in a short paragraph
Base isolation protects a building or bridge in an earthquake by separating it from the shaking ground. Bearings under the structure let the ground move sideways beneath it, so the structure itself moves slowly and is far less damaged [1]. The first isolated buildings went up in Japan in 1934 [2], and the first on rubber in 1969 [2]. Japan had more than 6,500 isolated buildings in 2012 [1].
as of 2026-11-11
How it works
The working principle in plain words, step by step
An earthquake shakes the ground back and forth quickly. A normal building is fixed to the ground and is shaken with it, and the floors above sway even harder. Base isolation puts a soft layer between the two. Each bearing is a sandwich of thin rubber sheets and steel plates [6]: stiff when pressed from above, so it carries the weight, but soft when pushed sideways. The building on top now sways slowly, much more slowly than the ground shakes, so little of the shaking reaches it [1]. A lead core in the centre bends and soaks up energy, then the rubber pulls it back [1, 6]. Friction pendulum bearings do the same job with a curved sliding surface [1].
as of 2026-11-11
Key figures
The handful of numbers that size it up, each with its unit, year and source
| Figure | Value | Unit | Year | Source |
|---|---|---|---|---|
| Seismically isolated buildings in Japan | 6500 | buildings (more than) | 2012 | [1] |
| Seismically isolated buildings in the United States | 125 | buildings (about) | 2012 | [1] |
| Isolated buildings approved in Japan by the Kobe earthquake | 85 | buildings (about) | 1995 | [1] |
| Lead-rubber bearings under the William Clayton Building, Wellington | 80 | bearings | 1982 | [3] |
| Sideways movement that building was designed to allow | 150 | mm | 1982 | [3] |
| Lead-rubber bearings under the Te Papa museum, Wellington | 152 | bearings | – | [6] |
as of 2026-11-11. The Japan and US counts are from an article of March 2012 [1]; 2012 is its publication year, as it gives no separate data year. The Te Papa page gives no date. In 2011 thousands of buildings and bridges worldwide used the lead-rubber bearing [4].
Where it is used
The main places and products the technology is found in
- Hospitals and emergency centres that must work after an earthquake
- Museums, such as Te Papa in Wellington
- Government, office and court buildings, such as the Foothill Communities Law and Justice Center
- Bridges, about as many in Japan as isolated buildings
- Apartment buildings, including retrofits after earthquakes
as of 2026-11-11
Scale today
How much of it there is now: units in use, made each year and who uses it
- Installed
- More than 6,500 isolated buildings and a similar number of bridges in Japan, and about 125 buildings in the United States [1]; thousands of structures worldwide on lead-rubber bearings in 2011 [4]
- Unit
- buildings
- Year
- 2012
- Note
- 2012 is the publication year of source 1, which gives no data year; no opened source gives a recent world count.
as of 2026-11-11
Sources
- What's Happened to Seismic Isolation of Buildings in the U.S.? (Andrew Taylor and Ian Aiken), STRUCTURE, March 2012 STRUCTURE magazine (NCSEA, CASE and SEI), 2012
- Base Isolation from a Historical Perspective (B. Carpani), 16th World Conference on Earthquake Engineering, Santiago, paper 4934 International Association for Earthquake Engineering (16WCEE), 2017
- Ministry of Health Building (William Clayton Building), heritage record Engineering New Zealand
- A tribute to Dr. William H. (Bill) Robinson, Seismic Isolation and Protection Systems 2(1), 1 to 3 Mathematical Sciences Publishers, 2011
- Halting the jolts: How Te Papa resists earthquakes Museum of New Zealand Te Papa Tongarewa