Material Insights · Understanding the Material World

Air conditioner: Bill of materials

About these figures

Which unit, study and year the composition figures describe, and how they vary

The bill is the EU review base case, a 3.5 kW reversible split unit of 41 kg with 0.98 kg of R-410A [19]; it is not the 5.25 kW Indian reference unit, and no inventory was found for that size. A 7.1 kW unit weighs 96 kg; no figure is interpolated. The 1.23 kg controller board has no node, and 3.53 kg of other materials are not itemised. The source does not split window, inverter or fixed speed units. The compressor, with its motor windings, is listed in new_products.

as of 2026-11-13

Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content

MaterialRoleAmount in one unitShare of the unit's mass
St SteelStructural18.45 kg45%
Ferrous metals, entered as cast iron, in the EU review base case: a 3.5 kW reversible split unit of 41 kg, not the 5.25 kW Indian unit. The catalogue has no iron node, so steel stands in. Mass share calculated (the study gives 45%) [19].
Cu CopperFunctional6.97 kg17%
Tube and sheet of the heat exchangers and windings, EU 3.5 kW base case, not the 5.25 kW Indian unit; mass share calculated [19].
PP PolypropyleneStructural6.355 kg15.5%
Bulk plastics of the casings and fan parts, EU 3.5 kW base case, not the 5.25 kW Indian unit; mass share calculated [19].
Al AluminiumFunctional2.87 kg7%
Sheet and extrusions, mainly fins; EU 3.5 kW base case, not the 5.25 kW Indian unit; mass share calculated [19].
HFC Fluorochemicals and refrigerantsFunctional0.98 kg2.4%
R-410A charge of the EU 3.5 kW base case, not the 5.25 kW Indian unit; the study counts the refrigerant inside its 4.51 kg of 'various other materials'. Mass share calculated [19].
PA Nylon (PA6, PA66)Structural0.615 kg1.5%
Technical plastics (PA 6), EU 3.5 kW base case, not the 5.25 kW Indian unit; mass share calculated [19].

as of 2026-11-13

How it is put together

The main steps from parts and materials to the finished unit

StepWhat happensSource
Form the heat exchangersCopper tubes are threaded through aluminium fins to make the indoor and outdoor coils. In one study more than half of the unit's resource use is due to the compressor and the heat exchangers, which are mainly iron and copper.[20]
Build the outdoor unitThe sealed compressor, outdoor coil, fan and valves are mounted in a steel casing and joined by brazed copper pipe.Standard process; no assembly study was opened
Build the indoor unitIndoor coil, blower, louvres and the controller board go into a plastic housing (or all parts into one box for a window unit).Standard process; no assembly study was opened
Evacuate, charge and testThe circuit is emptied of air, filled with a set charge of refrigerant and tested for leaks and performance.Standard process; no assembly study was opened

as of 2026-11-13

Technologies inside it

The technologies inside the product, with how much of each per unit

Embodies

as of 2026-11-13

Sources

  1. Review of Regulation 206/2012 and 626/2011: Air conditioners and comfort fans, Task 5 report (environment and economics) Viegand Maagøe and ARMINES for the European Commission (copy held by the Swedish Energy Agency), 2018, Tables 3, 6, 8 and 13; section 5.1.4; Annex 1 Table 22
  2. Life Cycle Assessment of Residential Air Conditioners Considering the Benefits of Their Use: A Case Study in Indonesia (Energies 14(2), 447) MDPI (Karkour, Ihara, Kuwayama, Yamaguchi, Itsubo), 2021