LeverLife stageChangeEffect per unitReadinessAdoptionWho actsSource
EfficiencyUseSell and buy higher star, inverter models and tighten the star tablesCSE averages put 5-star variable speed split models at about 740 kWh a year against about 1,008 kWh for 3-star (a saving of about 268 kWh, calculated); CLASP expects the 2026 standards to cut India's peak load by 8 to 10 GW by 2030Deployed; the labels revised on 1 January 2026Mandatory labelling for fixed and variable speed unitsBEE, makers, buyers[4][9]
EfficiencyComponents designBetter compressor and heat exchanger designs and a faster rise in minimum efficiencyLBNL (2014) found efficiency can be improved by over 40% cost-effectively; a 6.5% gain from a better compressor adds Rs 1,310Deployed in the best models (ISEER 6.1)The average unit sold is less than half as efficient as typical shelf unitsMakers, BEE[2][11][10]
SubstituteComponents designChange the refrigerant from R-410A to R-32 or R-290R-32 has a GWP of 675, about 70% below R-410A at 2,088; R-290 has 3.3; a kilogram of leaked R-410A equals about two tonnes of CO2Deployed: 17% of models listed on makers' websites used R-32 and 6% R-290 in 2017 (TERI, 2019); R-290 is used mainly in smaller domestic air conditioners (IIR, 2016)Units with R-290 or R-32 cost 10 to 15% moreMakers, ozone cell[16][40][12][45]
DesignUseLeak-tight circuits and trained servicing so that units are not refilled each yearAbout 40% of all units and about 80% of those over five years old are refilled each year; a 0.98 kg R-410A charge is about 2,046 kg CO2e if all leaked (calculated)Technician training targeted by the Cooling Action PlanLow; the iFOREST report quoted by Cooling Post says the plan lacks regulations and enforcement to prevent leakageMakers, servicing firms, regulators[30][19][16]
CircularityEnd of lifeRecover, reclaim or destroy the refrigerant at end of life and recycle metals formallyWorldwide formal e-waste management avoided 41 million tonnes of CO2e through recaptured refrigerants in 2022Deployed in some regions; in India the July 2023 rule amendment makes producers manage refrigerant by approved destruction technologies, but there is no mandate to recover or reclaim it effectivelyLow in IndiaRegulators, producers (EPR), recyclers[33][32][47]
Use lessUseDefault room temperature of 24 degrees Celsius and passive cooling of the roomNo per-unit saving found in the sources openedDeployed: default setting in force since 1 January 2020Applies to all rated unitsBEE, users, builders[3][13]

as of 2026-11-13

Sources

  1. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges Lawrence Berkeley National Laboratory (Phadke, Abhyankar, Shah), 2014
  2. BEE Notifies New Energy Performance Standards for Air Conditioners (press release) Press Information Bureau, Ministry of Power, 2020
  3. What is the star rating label of an air-conditioner telling you? Down To Earth (Sugeet Grover), 2025
  4. India Raises AC Efficiency Amid Growing Demand CLASP (Indira Akoijam), 2025
  5. The Future of Cooling International Energy Agency, page shows no date
  6. Modelling the Energy Efficiency Pathways for India's Room AC Sector The Energy and Resources Institute (Phore and Singh), 2022
  7. Mapping the Refrigerant Trends in India: An Assessment of Room AC Sector The Energy and Resources Institute (Singh, Gurumurthy, Shekhar), 2019
  8. India Cooling Action Plan (ICAP) IEA Policies Database, 2019
  9. Technology Transitions GWP Reference Table US Environmental Protection Agency, 2025, last updated 2 April 2026
  10. Review of Regulation 206/2012 and 626/2011: Air conditioners and comfort fans, Task 5 report (environment and economics) Viegand Maagøe and ARMINES for the European Commission (copy held by the Swedish Energy Agency), 2018, Tables 3, 6, 8 and 13; section 5.1.4; Annex 1 Table 22
  11. Concern over high AC refill rates in India Cooling Post, 2025, reporting the iFOREST report The Climate Cost of Air Conditioning
  12. Activating Circular Economy for Sustainable Cooling: Current Status and Barriers to Lifecycle Refrigerant Management in India Council on Energy, Environment and Water (Garg, Kumar, Bhasin), 2023
  13. Global e-Waste Monitor 2024: Electronic Waste Rising Five Times Faster than Documented E-waste Recycling UNITAR and ITU, 2024
  14. For India, cooling is now a necessity. Its choice of refrigerant will impact progress on climate goals Down To Earth (Shrotik Bose), 2025
  15. Natural refrigerants: the Indian perspective International Institute of Refrigeration, 2016
  16. E-Waste (Management) Second Amendment Rules, 2023 (G.S.R. 534(E)) Ministry of Environment, Forest and Climate Change, Gazette of India (copy held by the Tamil Nadu Pollution Control Board), 2023, rule 5(4) and Schedule II B