| Lever | Life stage | Change | Effect per unit | Readiness | Adoption | Who acts | Source |
|---|---|---|---|---|---|---|---|
| Efficiency | Use | Sell and buy higher star, inverter models and tighten the star tables | CSE averages put 5-star variable speed split models at about 740 kWh a year against about 1,008 kWh for 3-star (a saving of about 268 kWh, calculated); CLASP expects the 2026 standards to cut India's peak load by 8 to 10 GW by 2030 | Deployed; the labels revised on 1 January 2026 | Mandatory labelling for fixed and variable speed units | BEE, makers, buyers | [4][9] |
| Efficiency | Components design | Better compressor and heat exchanger designs and a faster rise in minimum efficiency | LBNL (2014) found efficiency can be improved by over 40% cost-effectively; a 6.5% gain from a better compressor adds Rs 1,310 | Deployed in the best models (ISEER 6.1) | The average unit sold is less than half as efficient as typical shelf units | Makers, BEE | [2][11][10] |
| Substitute | Components design | Change the refrigerant from R-410A to R-32 or R-290 | R-32 has a GWP of 675, about 70% below R-410A at 2,088; R-290 has 3.3; a kilogram of leaked R-410A equals about two tonnes of CO2 | Deployed: 17% of models listed on makers' websites used R-32 and 6% R-290 in 2017 (TERI, 2019); R-290 is used mainly in smaller domestic air conditioners (IIR, 2016) | Units with R-290 or R-32 cost 10 to 15% more | Makers, ozone cell | [16][40][12][45] |
| Design | Use | Leak-tight circuits and trained servicing so that units are not refilled each year | About 40% of all units and about 80% of those over five years old are refilled each year; a 0.98 kg R-410A charge is about 2,046 kg CO2e if all leaked (calculated) | Technician training targeted by the Cooling Action Plan | Low; the iFOREST report quoted by Cooling Post says the plan lacks regulations and enforcement to prevent leakage | Makers, servicing firms, regulators | [30][19][16] |
| Circularity | End of life | Recover, reclaim or destroy the refrigerant at end of life and recycle metals formally | Worldwide formal e-waste management avoided 41 million tonnes of CO2e through recaptured refrigerants in 2022 | Deployed in some regions; in India the July 2023 rule amendment makes producers manage refrigerant by approved destruction technologies, but there is no mandate to recover or reclaim it effectively | Low in India | Regulators, producers (EPR), recyclers | [33][32][47] |
| Use less | Use | Default room temperature of 24 degrees Celsius and passive cooling of the room | No per-unit saving found in the sources opened | Deployed: default setting in force since 1 January 2020 | Applies to all rated units | BEE, users, builders | [3][13] |
as of 2026-11-13
Sources
- Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges Lawrence Berkeley National Laboratory (Phadke, Abhyankar, Shah), 2014
- BEE Notifies New Energy Performance Standards for Air Conditioners (press release) Press Information Bureau, Ministry of Power, 2020
- What is the star rating label of an air-conditioner telling you? Down To Earth (Sugeet Grover), 2025
- India Raises AC Efficiency Amid Growing Demand CLASP (Indira Akoijam), 2025
- The Future of Cooling International Energy Agency, page shows no date
- Modelling the Energy Efficiency Pathways for India's Room AC Sector The Energy and Resources Institute (Phore and Singh), 2022
- Mapping the Refrigerant Trends in India: An Assessment of Room AC Sector The Energy and Resources Institute (Singh, Gurumurthy, Shekhar), 2019
- India Cooling Action Plan (ICAP) IEA Policies Database, 2019
- Technology Transitions GWP Reference Table US Environmental Protection Agency, 2025, last updated 2 April 2026
- Review of Regulation 206/2012 and 626/2011: Air conditioners and comfort fans, Task 5 report (environment and economics) Viegand Maagøe and ARMINES for the European Commission (copy held by the Swedish Energy Agency), 2018, Tables 3, 6, 8 and 13; section 5.1.4; Annex 1 Table 22
- Concern over high AC refill rates in India Cooling Post, 2025, reporting the iFOREST report The Climate Cost of Air Conditioning
- Activating Circular Economy for Sustainable Cooling: Current Status and Barriers to Lifecycle Refrigerant Management in India Council on Energy, Environment and Water (Garg, Kumar, Bhasin), 2023
- Global e-Waste Monitor 2024: Electronic Waste Rising Five Times Faster than Documented E-waste Recycling UNITAR and ITU, 2024
- For India, cooling is now a necessity. Its choice of refrigerant will impact progress on climate goals Down To Earth (Shrotik Bose), 2025
- Natural refrigerants: the Indian perspective International Institute of Refrigeration, 2016
- E-Waste (Management) Second Amendment Rules, 2023 (G.S.R. 534(E)) Ministry of Environment, Forest and Climate Change, Gazette of India (copy held by the Tamil Nadu Pollution Control Board), 2023, rule 5(4) and Schedule II B