Air conditioner: Working
What it is
The product and the job it does, in a short paragraph
A room air conditioner cools and dries the air of one room or a small flat by moving heat from indoors to the outdoor air. The functional unit is one room air conditioner of the common Indian size, 1.5 tonne or about 5.25 kW of cooling [1], as a split unit (indoor and outdoor parts) or a window unit. Its bill of materials and life-cycle stages come from an EU 3.5 kW unit, the only inventory found. Heat pumps for heating, chillers and ducted commercial systems are left out.
as of 2026-11-13
How it works
How it does its job, step by step in plain words
The indoor unit pulls room air over a cold coil, where the refrigerant boils and absorbs heat, and moisture condenses out. A sealed compressor in the outdoor unit squeezes the vapour, a fan blows outdoor air across the hot coil where the refrigerant turns back to liquid and sheds the heat, and an expansion device drops its pressure for the next round. A fixed speed compressor switches on and off to hold the set temperature. An inverter model changes the compressor speed instead, so it runs longer at lower power. India rates both on the Indian Seasonal Energy Efficiency Ratio (ISEER), the cooling delivered over a season divided by the electricity used, using Indian weather data from 24 to 43 degrees Celsius [4]. Window units put all parts in one box in the wall or window.
as of 2026-11-13
Key specifications
The numbers that describe it, each with unit, variant, year and source
| Spec | Value | Unit | Variant | Year | Source |
|---|---|---|---|---|---|
| Reference cooling capacity, 1.5 tonne | 5.25 | kW | – | 2017 | [1] |
| Unit mass, reversible split unit of 3.5 kW (EU review base case; a 7.1 kW unit weighs 96 kg) | 41 | kg | – | 2018 | [19] |
| Refrigerant charge, 3.5 kW split unit with R-410A (EU review base case) | 0.98 | kg | – | 2018 | [19] |
| Cooling hours a year assumed by the BEE label | 1600 | hours per year | – | 2025 | [4] |
| Label electricity, CSE average of 5-star variable speed split models (the article's example is a 1.5 tonne unit; the averages are not tied to a size in the text) | 740 | kWh per year | Inverter | 2025 | [4] |
| Label electricity, CSE average of 3-star variable speed split models (same caveat) | 1008.33 | kWh per year | Inverter | 2025 | [4] |
| Best air conditioner available in India (ISEER; 3.6 EER in 2010-11) | 6.1 | ISEER | – | 2020 | [11] |
| Electricity in 10 years, 2.6 kW unit at 4,400 hours a year, Indonesia | 13,780 | kWh | Inverter | 2021 | [20] |
| Electricity in 10 years, 2.6 kW unit at 4,400 hours a year, Indonesia (lower of two non-inverter models; the other used 36,030 kWh) | 31,770 | kWh | Fixed speed | 2021 | [20] |
| Service life used in studies: India (LBNL) 7, EU review 12, Indonesia 10, Japan average 14 | 7 | years (India) | – | 2017 | [1][19][20][21] |
as of 2026-11-13
Variants
The variants whose make-up or footprint differs a lot, what defines each and its share of units
| Variant | Defining spec | Year | Source |
|---|---|---|---|
| Inverter | Variable speed compressor; BEE's split AC schedule names 'variable capacity air conditioners'. In one 10-year Indonesian study it used 13,780 kWh against 31,770 and 36,030 kWh for two fixed speed models of the same 2.6 kW size. The bill of materials and life-cycle stages here are for the EU 3.5 kW base case and are not split by variant | 2021 | No national share of units found [20][46] |
| Fixed speed | Compressor that runs at one speed and cycles on and off; star labelling became mandatory for fixed speed units in 2009 and for inverter units in 2018. The bill of materials and life-cycle stages here are for the EU 3.5 kW base case and are not split by variant; no source gives yearly electricity for a comparable fixed speed unit | 2020 | No national share of units found [3][8] |
as of 2026-11-13
Limits
The physical limits set by science and the engineering limits of today's design, with today's value
| Limit | Kind | Limit | Today | Unit | Source |
|---|---|---|---|---|---|
| Efficiency ceiling set by the temperatures between which the cycle works (Carnot limit; no figure for the ceiling was found in the sources) | Physical | – | 6.1 | ISEER, best air conditioner available in India, 2019-20 | [11] |
| Average efficiency of air conditioners sold against the best on the shelf (engineering; sold units are less than half as efficient as typical shelf units, about one third of the best available technology) | Engineering | – | – | ratio, no single value | [10] |
| Climate warming per kg of refrigerant leaked (100-year GWP, engineering choice of refrigerant): R-410A against R-32 and R-290 | Engineering | 3.3 | 2088 | kg CO2e per kg, R-410A today; R-290 is the lowest at 3.3 | [16] |
as of 2026-11-13
Science it relies on
The science principles it works by or is limited by
Relies on- Vapour-liquid equilibrium (Raoult's law) The refrigerant boils at low pressure to absorb room heat and condenses at high pressure to release it outdoors.
- Second law of thermodynamics Heat only flows from cold to warm if work is done, which is the electricity the compressor takes.
- Carnot's limit on heat engines The ideal efficiency falls as the gap between room and outdoor temperature widens, so hot afternoons cost the most electricity.
- Greenhouse effect Fluorinated refrigerants that leak add to warming far more per kilogram than carbon dioxide, which is why the refrigerant is being changed.
as of 2026-11-13
Sources
- Accelerating Energy Efficiency Improvements in Room Air Conditioners in India: Potential, Costs-Benefits, and Policies (LBNL-1005798) Lawrence Berkeley National Laboratory (Abhyankar, Shah, Park, Phadke), 2017
- BEE Notifies New Energy Performance Standards for Air Conditioners (press release) Press Information Bureau, Ministry of Power, 2020
- What is the star rating label of an air-conditioner telling you? Down To Earth (Sugeet Grover), 2025
- Energy Efficiency Star Ratings Mandatory For Cooling Appliances from January 1, 2026 Thermal Control Business Update, 2026
- The Future of Cooling International Energy Agency, page shows no date
- Modelling the Energy Efficiency Pathways for India's Room AC Sector The Energy and Resources Institute (Phore and Singh), 2022
- Technology Transitions GWP Reference Table US Environmental Protection Agency, 2025, last updated 2 April 2026
- Review of Regulation 206/2012 and 626/2011: Air conditioners and comfort fans, Task 5 report (environment and economics) Viegand Maagøe and ARMINES for the European Commission (copy held by the Swedish Energy Agency), 2018, Tables 3, 6, 8 and 13; section 5.1.4; Annex 1 Table 22
- Life Cycle Assessment of Residential Air Conditioners Considering the Benefits of Their Use: A Case Study in Indonesia (Energies 14(2), 447) MDPI (Karkour, Ihara, Kuwayama, Yamaguchi, Itsubo), 2021
- Life Cycle Resource Use of Air Conditioner from the Perspective of Total Material Requirement Springer Nature Singapore, in EcoDesign for Sustainable Products, Services and Social Systems II (Hamasuna, Sato, Kosai, Kashiwakura, Yamasue), 2024
- Notification S.O. 3984(E): amendment of S.O. 2528(E) on star labelling of split air conditioners Ministry of Power, Gazette of India, 2025, dated 28 August 2025; Table 3.2(h)