Ceiling fan: Footprint
Raw materials in one unit
Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions
| Variant | Material | Amount (kg) | Through | Emission factor (kg CO2e per kg) | Emissions (kg CO2e) |
|---|---|---|---|---|---|
| Induction | Aluminium | 2.2 | – | 14.8 | 32.6 |
| Induction | Steel | 1.1 | – | 1.92 | 2.1 |
| Induction | Copper | 0.3 | – | 3.965 | 1.2 |
| BLDC | Iron ore | 0.69 | Permanent magnet | – | – |
| BLDC | Rare earths | 0.3 | Permanent magnet | – | – |
| BLDC | Nickel | 0.011 | Permanent magnet | – | – |
| BLDC | Boron | 0.01 | Permanent magnet | – | – |
Worked out from data
The site's estimate
Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors
| Variant | Stage | Place | Emissions (kg CO2e) | Mass covered by factors |
|---|---|---|---|---|
| Induction | Making | World | 35.9 | 100% |
| Induction | Use | World | 660 | 100% |
| Induction | Making | India | 35.9 | 100% |
| Induction | Use | India | 965 | 100% |
| BLDC | Making | World | 6.41 | 0% |
| BLDC | Use | World | 279 | 100% |
| BLDC | Making | India | 9.38 | 0% |
| BLDC | Use | India | 409 | 100% |
Worked out from data
Energy in use
Energy one unit uses per year of use, by carrier
Energy in use- El Electricity 144 kWh per year · lifetime 10 years Induction Calculated, illustrative, India: 75 W at top speed x 8 hours a day x 240 days (8 months) = 144 kWh a year, from CEEW's survey-based use pattern [1][36]. Real fans run at lower speeds part of the time, so this is a ceiling; 1,350 hours a year gives 101 kWh [5] and 3,694 hours (urban survey) 277 kWh [37]. Life of 10 years is a study assumption [6][36].
- El Electricity 61 kWh per year · lifetime 10 years BLDC Calculated, illustrative, India: 32 W at top speed (CEEW's figure; tested 5-star range 26.9 to 35.42 W) x 8 hours a day x 240 days = 61 kWh a year [36][4]. At 1,350 hours a year it is 43 kWh and at 3,694 hours 118 kWh [5][37].
as of 2026-11-17
Emissions by stage
Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant
| Stage | Value | Range | Unit | Variant | Place | Year | Source |
|---|---|---|---|---|---|---|---|
| Use | 965 | 678 to 1856 kg CO2e per fan over 10 years (calculated: 75 W x 1,920 h a year x 10 y x 0.67 kg/kWh; low 1,350 h, high 3,694 h a year) | kg CO2e per fan over 10 years (calculated: 75 W x 1,920 h a year x 10 y x 0.67 kg/kWh; low 1,350 h, high 3,694 h a year) | Induction | India | 2025 | [1][36][5][37][21] |
| Use | 412 | 289 to 792 kg CO2e per fan over 10 years (calculated: 32 W x 1,920 h a year x 10 y x 0.67 kg/kWh; low 1,350 h, high 3,694 h a year) | kg CO2e per fan over 10 years (calculated: 32 W x 1,920 h a year x 10 y x 0.67 kg/kWh; low 1,350 h, high 3,694 h a year) | BLDC | India | 2025 | [36][4][5][37][21] |
as of 2026-11-17. No life-cycle study or declaration for a ceiling fan was found, so making, logistics and end of life are not given and no stage shares can be worked out; the use figures are calculated.
End of life
What happens to a unit when it is thrown away: collection, reuse, recycling and disposal shares, by place
| Route | Share | Place | Year | Source |
|---|---|---|---|---|
| All e-waste processed in India, FY 2023-24 (no ceiling fan figure) | 43 | India | 2023 | [32] |
as of 2026-11-17
Recovered as
The commodities and chemicals recovered at end of life, with recovery rates
Recovered as- St Steel Recycling Steel laminations and parts are recoverable metal [22]; no source gives a recovery rate for fans.
- Cu Copper Recycling Copper winding is recoverable metal; some newer fans use aluminium or copper-clad aluminium windings instead [22][30]. No source gives a recovery rate.
- Al Aluminium Recycling Die cast aluminium covers and rotor cages are recoverable metal [22]; no source gives a recovery rate.
as of 2026-11-17
End of life in India
Collection and recycling in India, including the informal sector
Electric fans are listed in Schedule I of India's E-Waste (Management) Rules, 2022, in force from 1 April 2023, so fan producers come under extended producer responsibility [20]. India processed 43% of its 1.751 million tonnes of e-waste in 2023-24 [32]. A fan with quality copper winding can last 15 to 20 years, against under 10 years with substandard winding [30]. No source opened describes what happens to old fans or the informal sector's share.
as of 2026-11-17
Sources
- Stars Are Mandatory Now: How the Indian Fan Market Is Changing Council on Energy, Environment and Water (CEEW), 2023
- Comparative Product Testing: BLDC Ceiling Fans: Choosing Efficiency! Consumer VOICE, hosted by the Department of Consumer Affairs, 2023
- Ceiling Fan: The Overlooked Appliance in Energy Efficiency Discussions (Singh, Barve, Sant) Prayas Energy Group, Pune, Annexure, Table A-1
- Efficiency improvement opportunities for ceiling fans (Shah, Sathaye, Phadke, Letschert), vol. 8, pp. 37 to 50 Energy Efficiency, Springer, 2015
- E-Waste (Management) Rules, 2022, G.S.R. 801(E), Gazette of India Ministry of Environment, Forest and Climate Change (Gazette copy hosted by the Andaman and Nicobar Administration), 2022
- Global Electricity Review 2026: major countries and regions Ember, 2026
- Ceiling fan plant setup cost in India: manufacturing process flow, machinery, DPR and financial model 2026 IMARC Group, 2026
- Why Your Parents' Fan Still Works? And Yours Won't! (newsletter, March 2025) International Copper Association India (ICA India), 2025
- India's e-waste surges by 73% in 5 years Down To Earth, 2024
- Business Model for Scaling Up Super-Efficient Appliances: A Deep Dive on Ceiling Fans in India (Aggarwal and Agrawal) Council on Energy, Environment and Water (CEEW), 2022
- Evaluating Appliance Ownership and Usage Pattern in India (Walia, Energy Evaluation Asia Pacific 2019) Energy Evaluation Asia Pacific, 2019