Refrigerator: Bill of materials
About these figures
Which unit, study and year the composition figures describe, and how they vary
The bill is Lewandowska's 2021 inventory of a modelled 340 litre EU refrigerator-freezer of 58.4 kg, with hypothetical locations, ecoinvent 3.6 data and some virtual data [11]. It also lists 0.479 kg of methylcyclopentane, which has no node; its inputs add to 58.68 kg. The Japanese 501 litre model of 102.5 kg (40.4 kg iron, 40.7 kg plastics) [9] and Liebherr's freezers [13] are comparisons only and are not added to the bill. The compressor is in new_products.
as of 2026-11-13
Direct materials
The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content
| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| St Steel | Structural | 32.093 kg | 55% |
| Low-alloyed steel of the cabinet and door in the 58.4 kg modelled refrigerator; mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| PU Polyurethanes (MDI, TDI, polyols) | Functional | 11.278 kg | 19.3% |
| Insulating foam, entered in the study as 6.479 kg of phenyl isocyanate plus 4.799 kg of polyol (calculated sum); mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| PS Polystyrene and EPS | Structural | 10.222 kg | 17.5% |
| High impact polystyrene liners; mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| Al Aluminium | Functional | 2.189 kg | 3.7% |
| Primary aluminium ingot (evaporator and parts); mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| Cu Copper | Functional | 1.308 kg | 2.2% |
| Tubes and windings; mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| PVC PVC | Structural | 0.466 kg | 0.8% |
| Suspension PVC; mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| LLDPE Polyethylene (LDPE, LLDPE) | Structural | 0.297 kg | 0.5% |
| Linear low density polyethylene; mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
| HFC Fluorochemicals and refrigerants | Functional | 0.239 kg | 0.4% |
| The study's virtual inventory models the refrigerant as 1,1-difluoroethane (HFC-152a); Indian units mostly use R-600a (isobutane), which has no node, and a real R-600a charge is smaller (0.076 kg in one LG model). Mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer [11]. | |||
| EPX Epoxy resins | Structural | 0.111 kg | 0.2% |
| Epoxy resin, liquid; mass share calculated. Lewandowska's modelled 340 litre EU refrigerator-freezer, partly virtual inventory data [11]. | |||
as of 2026-11-13
How it is put together
The main steps from parts and materials to the finished unit
| Step | What happens | Source |
|---|---|---|
| Form the cabinet and door | Steel sheet is cut and formed into the cabinet shell and door panels, and plastic liners are moulded. | Standard process; no assembly study was opened |
| Fit the cooling circuit | The condenser and evaporator tubes, the sealed compressor and the capillary tube are fitted and joined. | Standard process; no assembly study was opened |
| Inject the foam | A polyurethane foam, blown with a hydrocarbon gas (cyclopentane in the Japanese model; hydrocarbon foaming agents at Liebherr since 1993), is injected between shell and liner to insulate the walls. | [9][13] |
| Evacuate, charge and test | The circuit is emptied of air, filled with a small charge of R-600a (isobutane) and tested for leaks and cooling. | [9][12] |
as of 2026-11-13
Technologies inside it
The technologies inside the product, with how much of each per unit
Embodies- HP Heat pumps, air conditioning and refrigeration 1 unit The vapour compression cycle, packaged for a cold cabinet; its principle and history are on the technology page.
as of 2026-11-13
Sources
- Report on Life Cycle Inventory (LCI) Analyses of Refrigerators Japan Electrical Manufacturers' Association (JEMA), LCA-WG, 2014
- Environmental Life Cycle Assessment of Refrigerator Modelled with Application of Various Electricity Mixes and Technologies (Energies 14(17), 5350) MDPI (Lewandowska, Kurczewski, Joachimiak-Lechman, Zablocki), 2021
- Environmental Product Declaration: Objet Collection refrigerator (NEPD-3952-2990-EN) The Norwegian EPD Foundation, LG Electronics, 2022