Stent: Bill of materials
About these figures
Which unit, study and year the composition figures describe, and how they vary
No source gives the mass of a stent or its materials in grams. The materials come from one FDA summary for a cobalt-chromium drug-eluting stent (Xience V), two reviews and a maker's patient page, so they describe the main platforms, not one product. The delivery balloon catheter is not a node and is listed in new_products.
as of 2026-11-13
Direct materials
The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content
Variant 1 Not stated| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| St Steel | Structural | Not given | – |
| Most early stents were stainless steel and balloon-expandable [5]; Medtronic says a stent can be made of medical-grade stainless steel [4]. No source gives the mass. | |||
| Ni Nickel | Structural | Not given | – |
| Self-expanding nitinol stents are a nickel and titanium alloy [5]; Table 1 of a 2010 review gives L605 cobalt-chromium as 10% nickel by weight (table value) [1]. No stent mass is given. | |||
| Ti Titanium | Structural | Not given | – |
| Nitinol, the shape memory alloy of some self-expanding stents, is made of nickel and titanium [5]. No source gives the mass. | |||
| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| Co Cobalt | Structural | Not given | – |
| The XIENCE V stent is a medical-grade L-605 cobalt-chromium alloy [3]; later platforms used cobalt-chromium instead of stainless steel to make them more flexible [5]. No source gives the mass. | |||
| Cr Chromium | Structural | Not given | – |
| Chromium is the partner metal in the cobalt-chromium and platinum-chromium stent alloys [2][3]. No source gives the mass. | |||
| Pt Platinum | Structural | Not given | – |
| Some new-generation stents use platinum-chromium, which is denser than stainless steel or cobalt-chromium [1][2]. No source gives the mass. | |||
| PTFE Fluoropolymers (PTFE, PVDF) | Functional | Not given | – |
| The XIENCE V drug matrix layer is PVDF-HFP, a copolymer of vinylidene fluoride and hexafluoropropylene; a poly n-butyl methacrylate layer bonds it to the stent [3]. No source gives the mass. | |||
| API Small-molecule APIs | Functional | Not given | – |
| Drug-eluting stents carry an antiproliferative drug, everolimus in the XIENCE V [3]; no amount is given here. | |||
Indicative · as of 2026-11-13. No amount per stent was found: the sources name materials but not masses.
How it is put together
The main steps from parts and materials to the finished unit
| Step | What happens | Technology | Source |
|---|---|---|---|
| Alloy | A stainless steel, cobalt-chromium or platinum-chromium alloy is chosen for the platform [2] | – | [2] |
| Cutting | A thin metal tube is cut by laser into the mesh; a 2024 review says laser cutting transformed stent design [6] | Laser | [6] |
| Surface treatment | Surfaces are treated to improve biocompatibility, as an equipment maker describes it [16] | – | [16] |
| Coating | For drug-eluting stents a polymer carrier holding the drug is coated on the metal [6][3] | – | [6][3] |
| Mounting | The stent is mounted on the balloon of its delivery catheter [4] | – | [4] |
| Testing | Each stent is tested against safety and efficacy standards, as an equipment maker describes it [16] | – | [16] |
as of 2026-11-13
Technologies used to make it
The technologies used to make it, at which step
Made with- Lsr Laser Cutting the thin metal tube into the stent mesh A 2024 review says laser cutting technology transformed stent design and describes laser-cut tubular stents; no share of output is given [6].
as of 2026-11-13
Technologies inside it
The technologies inside the product, with how much of each per unit
Embodies- Stn Coronary stent The scaffold technology is the twin node; one stent is one mesh tube.
as of 2026-11-13
Sources
- Does the Metal Matter? An overview of next-generation stent platforms. Cardiac Interventions Today, May/June 2010 (Cannon, Daniel, Hood and Yakubov), 2010, pp. 41 to 47; strut thickness text; Table 1, nominal elemental composition by weight
- State of the art: coronary artery stents – past, present and future EuroIntervention (Stefanini, Byrne, Windecker and Kastrati), 2017, EuroIntervention 2017;13:706-716
- Summary of Safety and Effectiveness Data, XIENCE V Everolimus Eluting Coronary Stent System (PMA P070015) US Food and Drug Administration (applicant Abbott Vascular, Cardiac Therapies), 2008, FDA notice of approval 2 July 2008; device description
- What Is Balloon Angioplasty and Stenting? Medtronic (UK patient site)
- Modern Stents: Where Are We Going? Rambam Maimonides Medical Journal (Kobo and others), 2020, RMMJ 2020;11(2):e0017, DOI 10.5041/RMMJ.10403
- Inception of the coronary stent: a story of successful collaboration between innovative scientists and the biotechnology industry REC: Interventional Cardiology 6(4):321-331 (Macaya-Ten, Gonzalo, Escaned, Macaya), 2024
- What is the manufacturing process of a heart stent? Aerotech, a maker of laser and motion equipment (In Motion blog), 2026, published 28 April 2026; an equipment maker's own material, not a peer-reviewed source