Material Insights · Understanding the Material World

Stent: Bill of materials

About these figures

Which unit, study and year the composition figures describe, and how they vary

No source gives the mass of a stent or its materials in grams. The materials come from one FDA summary for a cobalt-chromium drug-eluting stent (Xience V), two reviews and a maker's patient page, so they describe the main platforms, not one product. The delivery balloon catheter is not a node and is listed in new_products.

as of 2026-11-13

Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content

Variant 1 Not stated
MaterialRoleAmount in one unitShare of the unit's mass
St SteelStructuralNot given –
Most early stents were stainless steel and balloon-expandable [5]; Medtronic says a stent can be made of medical-grade stainless steel [4]. No source gives the mass.
Ni NickelStructuralNot given –
Self-expanding nitinol stents are a nickel and titanium alloy [5]; Table 1 of a 2010 review gives L605 cobalt-chromium as 10% nickel by weight (table value) [1]. No stent mass is given.
Ti TitaniumStructuralNot given –
Nitinol, the shape memory alloy of some self-expanding stents, is made of nickel and titanium [5]. No source gives the mass.
Variant 2 Drug-eluting
MaterialRoleAmount in one unitShare of the unit's mass
Co CobaltStructuralNot given –
The XIENCE V stent is a medical-grade L-605 cobalt-chromium alloy [3]; later platforms used cobalt-chromium instead of stainless steel to make them more flexible [5]. No source gives the mass.
Cr ChromiumStructuralNot given –
Chromium is the partner metal in the cobalt-chromium and platinum-chromium stent alloys [2][3]. No source gives the mass.
Pt PlatinumStructuralNot given –
Some new-generation stents use platinum-chromium, which is denser than stainless steel or cobalt-chromium [1][2]. No source gives the mass.
PTFE Fluoropolymers (PTFE, PVDF)FunctionalNot given –
The XIENCE V drug matrix layer is PVDF-HFP, a copolymer of vinylidene fluoride and hexafluoropropylene; a poly n-butyl methacrylate layer bonds it to the stent [3]. No source gives the mass.
API Small-molecule APIsFunctionalNot given –
Drug-eluting stents carry an antiproliferative drug, everolimus in the XIENCE V [3]; no amount is given here.

Indicative · as of 2026-11-13. No amount per stent was found: the sources name materials but not masses.

How it is put together

The main steps from parts and materials to the finished unit

StepWhat happensTechnologySource
AlloyA stainless steel, cobalt-chromium or platinum-chromium alloy is chosen for the platform [2]– [2]
CuttingA thin metal tube is cut by laser into the mesh; a 2024 review says laser cutting transformed stent design [6]Laser[6]
Surface treatmentSurfaces are treated to improve biocompatibility, as an equipment maker describes it [16]– [16]
CoatingFor drug-eluting stents a polymer carrier holding the drug is coated on the metal [6][3]– [6][3]
MountingThe stent is mounted on the balloon of its delivery catheter [4]– [4]
TestingEach stent is tested against safety and efficacy standards, as an equipment maker describes it [16]– [16]

as of 2026-11-13

Technologies used to make it

The technologies used to make it, at which step

Made with
  • Lsr Laser Cutting the thin metal tube into the stent mesh A 2024 review says laser cutting technology transformed stent design and describes laser-cut tubular stents; no share of output is given [6].

as of 2026-11-13

Technologies inside it

The technologies inside the product, with how much of each per unit

Embodies

as of 2026-11-13

Sources

  1. Does the Metal Matter? An overview of next-generation stent platforms. Cardiac Interventions Today, May/June 2010 (Cannon, Daniel, Hood and Yakubov), 2010, pp. 41 to 47; strut thickness text; Table 1, nominal elemental composition by weight
  2. State of the art: coronary artery stents – past, present and future EuroIntervention (Stefanini, Byrne, Windecker and Kastrati), 2017, EuroIntervention 2017;13:706-716
  3. Summary of Safety and Effectiveness Data, XIENCE V Everolimus Eluting Coronary Stent System (PMA P070015) US Food and Drug Administration (applicant Abbott Vascular, Cardiac Therapies), 2008, FDA notice of approval 2 July 2008; device description
  4. What Is Balloon Angioplasty and Stenting? Medtronic (UK patient site)
  5. Modern Stents: Where Are We Going? Rambam Maimonides Medical Journal (Kobo and others), 2020, RMMJ 2020;11(2):e0017, DOI 10.5041/RMMJ.10403
  6. Inception of the coronary stent: a story of successful collaboration between innovative scientists and the biotechnology industry REC: Interventional Cardiology 6(4):321-331 (Macaya-Ten, Gonzalo, Escaned, Macaya), 2024
  7. What is the manufacturing process of a heart stent? Aerotech, a maker of laser and motion equipment (In Motion blog), 2026, published 28 April 2026; an equipment maker's own material, not a peer-reviewed source