Material Insights · Understanding the Material World

Electric heating: Levers

Held back most by

Economics

The conversion is already close to all the electricity becoming heat [11]; what stops it spreading in Indian industry is price. Grid power at retail rates is Rs 7.81 per kWh against coal at Rs 1.09 per kWh of fuel energy, and the report finds grid-powered electric resistance boilers uncompetitive [14].

The six layers

Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it

Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A hard limit comes from mathematics or nature and can only be sidestepped; a soft limit moves with effort, scale, money or policy.

  1. 1 Mathematics Hard limit

    Mathematics is the language of its physics

    What it gives. The power a heating element gives off follows from its resistance and the current through it, which lets a maker size a kettle or furnace element [11].

    The idea. Role: language. A physical law does the work and mathematics writes it down. In a resistor the lost electrical energy appears as heat in the material [11]. A 2,000 W kettle on 230 V (both assumed) needs an element of 26.5 Ω and draws 8.7 A (calculated).

    The limit. Power in a resistor is I²R, or V²÷R, so at a fixed supply voltage the element's resistance fixes how much heat it can give [11].

    What could unlock it. The mathematics is no barrier; the lever is where the heat appears, as in induction, which heats the pan itself [4].

    Show the maths P = I2 × R = V2 ÷ R
    P
    the power given off as heat, in watts
    I
    the current through the element, in amperes
    R
    the resistance of the element, in ohms
    V
    the voltage across the element, in volts

    In plain words. When current pushes through a wire that resists it, the wire gets hot. A thin, resistant wire gets hotter than a thick one. The formula says how many watts of heat you get for a given push and a given resistance.

    Worked example. A kettle of 2,000 W on 230 V (both assumed). R = V² ÷ P = 230² ÷ 2,000 = 26.45 Ω, and I = P ÷ V = 2,000 ÷ 230 = 8.70 A (calculated). Check: I² × R = 8.70² × 26.45 = 2,002 W, which is 2,000 W to the rounding (calculated) [11].

  2. 2 Science Hard limit

    What it gives. A resistor turns the electrical energy it uses into heat [11], and a heat pump can in many cases deliver at least twice as much heat as it uses in electricity by moving heat from outside [12].

    The idea. A heat pump's coefficient of performance is the heat delivered divided by the work put in, and by the second law it is always greater than 1 [12]. For a home at 45 °C against outside air at -15 °C the ideal (Carnot) value is 5.30, so an electric room heater would cost 5.30 times as much as that ideal heat pump for the same heat [12]. Real heat pumps range from about 2 to 4 [12].

    The limit. Carnot limit for a heat pump: the best possible COP is the inverse of the Carnot efficiency between the two temperatures [12].

    What could unlock it. Resistance heating can only turn energy into heat; moving heat instead of making it is the route round it [12].

    HP Heat pumps, air conditioning and refrigerationMVR Industrial heat pumps and vapour recompression

    Show the maths COPhp = Qh ÷ W = 1 ÷ Eff, with EffC = 1 - Tc ÷ Th
    COPhp
    the heat delivered for each unit of work put in, as a number
    Qh
    the heat delivered to the warm space, in joules
    W
    the electrical work put in, in joules
    Eff
    the efficiency of the heat engine run in reverse
    EffC
    the Carnot efficiency between the two temperatures
    Tc
    the temperature of the cold side (outside air), in kelvin
    Th
    the temperature of the warm side (the room), in kelvin

    In plain words. A heater makes heat from electricity: one unit of electricity gives one unit of heat. A heat pump does not make the heat. It moves heat from the cold outside to the warm inside, a bit like a pump moving water uphill. So one unit of electricity can move several units of heat. The smaller the gap in temperature, the more it can move.

    Worked example. Inside at 45 °C (318 K) and outside at -15 °C (258 K), as in the textbook example [12]. EffC = 1 - 258 ÷ 318 = 0.1887 and COP = 1 ÷ 0.1887 = 5.30 (calculated) [12]. A resistance heater always gives 1.00, so the Carnot ceiling is 5.3 times better.

  3. 3 Engineering Soft limit

    What it gives. Heat appears directly in the element, the metal or the food, so most of the electricity reaches the target: an induction hob passes about 85% to the pan, a resistance hob 75% to 80% and gas about 32% [4].

    The idea. Electric arc furnaces melt scrap steel: the DOE's 2000 table gives actual requirements of 2.1 to 2.4 GJ per tonne of liquid steel for electric furnaces, against an absolute minimum of 1,327 MJ per tonne to heat and melt scrap and superheat it [13]. That is 58% to 81% more than the minimum (calculated).

    The limit. Heat that escapes before it reaches the target: real furnaces use well over the minimum, which counts only the energy needed in the steel itself [13].

    What could unlock it. Induction heats the pan or workpiece itself, which is why it beats resistance and gas on efficiency to the pan [4].

  4. 4 Production Soft limit

    What it gives. Electric heat is already made and used at scale: electric furnaces made 30.3% of the 1,848.9 Mt of crude steel in the countries worldsteel lists for 2025, and 57.7% of India's 164.9 Mt [5].

    The idea. The table heads the column 'Electric' and does not split arc furnaces from induction furnaces [5]. Elements, coils and furnaces are mature products made by many firms.

    The limit. The sources show no manufacturing bottleneck for electric heating; what holds it back is the cost of electricity (economics).

    What could unlock it. None needed at the production layer.

  5. 5 Economics Soft limit Binds most today

    What it gives. Electricity is the running cost, and it is dear against coal: Energy Innovation's model has coal at Rs 1.09 per kWh of fuel energy and grid power at retail rates at Rs 7.81 per kWh [14].

    The idea. The report finds grid-powered electric resistance boilers uncompetitive, but electrified heat cheaper than coal in three of five temperature bands when powered by renewables [14]. Tata Power Mumbai's FY 2025-26 average billing rates are Rs 7.57 per kWh for homes (LT I(B)) and Rs 7.29 for HT industry (row HT I); LT industry pays more, Rs 8.03 under 20 kW and Rs 9.21 over 20 kW [15].

    The limit. A resistance heater gives one unit of heat for each unit of electricity bought [11], so its heat can cost no less than the electricity itself.

    What could unlock it. Removing cross-subsidies could lower industrial power prices by about 20% on average [14], and renewable power with storage lowers the price of electric heat [14].

    MVR Industrial heat pumps and vapour recompression

    Show the maths LCOE = (FCR × CAPEX + FOM) ÷ (CF × 8,760) + VOM + FUEL
    LCOE
    the levelised cost of energy, per unit of energy delivered
    FCR
    the fixed charge rate: the share of the up-front cost paid back each year
    CAPEX
    the up-front cost of the equipment
    FOM
    the fixed cost of operating and maintenance each year
    CF
    the capacity factor: the share of the year the equipment runs at full power
    8,760
    the hours in a year
    VOM
    the operating cost for each unit of energy
    FUEL
    the cost of the fuel or power for each unit of energy delivered, which is its price divided by the efficiency

    In plain words. The cost of heat has a part for buying the equipment and a part for the energy it eats. For electric heaters the equipment is cheap, so the energy part is nearly all of the bill. That part is the price of a unit of electricity, divided by how many units of heat you get from it.

    Worked example. Fuel part of the formula [16] only, ignoring equipment (calculated). Coal heat: Rs 1.09 ÷ 0.903 = Rs 1.21 per kWh of heat, using the DOE's 90.3% boiler efficiency for coal [14][17]. Grid resistance heat: Rs 7.81 ÷ 1.00 = Rs 7.81, which is 6.5 times as much. A heat pump with a COP of 3 (assumed, within the real range of 2 to 4 [12]) on the same grid power: Rs 7.81 ÷ 3 = Rs 2.60, or 2.2 times coal (calculated).

  6. 6 Resources and rules Soft limit

    What it gives. Electricity tariffs, set by regulators, decide how dear electric heat is for industry: users in industry and commerce pay higher rates to cross-subsidise homes and farms [14].

    The idea. Removing the cross-subsidies could lower industrial power prices by about 20% on average, and retail electricity prices are 1.6 to 3.1 times higher than the price of renewable power [14]. At Tata Power Mumbai, HT industry pays an average Rs 7.29 per kWh in 2025-26, close to the Rs 7.57 for homes, but LT industry pays Rs 8.03 to Rs 9.21 [15].

    The limit. Tariff rules: industrial users carry a cross-subsidy that raises the price of grid power for electric heat [14].

    What could unlock it. Captive renewable power with storage, priced at Rs 4.80 per kWh in the report's model, would be cheaper than retail grid power at Rs 7.81 [14].

as of 2026-11-23

Sources

  1. 2021 ENERGY STAR Emerging Technology Award: Residential Induction Cooking Tops US EPA ENERGY STAR, 2021
  2. World Steel in Figures 2026 World Steel Association, 2026, Crude steel production by process, 2025
  3. Electrical Energy and Power (University Physics Volume 2, section 9.5) OpenStax, 2016
  4. Applications of Thermodynamics: Heat Pumps and Refrigerators (College Physics 2e, section 15.5) OpenStax, 2022
  5. Theoretical Minimum Energies to Produce Steel for Selected Conditions (Fruehan, Fortini, Paxton and Brindle, Carnegie Mellon University) US Department of Energy, Office of Industrial Technologies, 2000
  6. Electrifying Industrial Heat in India Energy Innovation, 2026
  7. Press Note: Multi-Year Tariff Order for Tata Power Company Limited (Mumbai distribution), FY 2025-26 to FY 2029-30 Maharashtra Electricity Regulatory Commission, 2025
  8. Equations and Variables in the ATB (2024) NREL, 2024
  9. Benchmark the Fuel Cost of Steam Generation, Steam Tip Sheet #15 (DOE/GO-102012-3391) US Department of Energy, Advanced Manufacturing Office, 2012