Industrial heat pumps and vapour recompression: Levers
Held back most by
Economics
The physics leaves room: a Carnot heat pump lifting heat from 80 °C to 100 °C could deliver 18.65 units of heat per unit of work (calculated, assumed temperatures) [10]. In Energy Innovation's model for India, a grid-powered heat pump below 100 °C costs Rs 2.58 per kWh of heat against Rs 2.59 for a coal boiler, a near tie, because grid electricity is typically expensive for industrial firms; on captive renewable power it costs Rs 1.60 [11]. The report gives an 11% discount rate and a 26-year lifetime but no price year [11].
The six layers
Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it
Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A hard limit comes from mathematics or nature and can only be sidestepped; a soft limit moves with effort, scale, money or policy.
- 1 Mathematics Hard limit
Mathematics is the language of its physics
What it gives. The bookkeeping of heat delivered against electricity spent, which sizes every heat pump and recompressor.
The idea. A physical law makes the machine work and mathematics counts it, so the role is language. The coefficient of performance is the heat delivered divided by the work put in, which is the heat delivered over the heat delivered minus the heat taken from the cold side [10]. For MVR, GenLess says a rise of around 5 °C allows a very high COP, often close to 50 [12].
The limit. The sums only count heat in and out; the size of the ratio is set by the next layer [10].
What could unlock it. MVR is described as an open cycle heat pump, so the same sums apply to it [12].
Show the maths
KP = Qh ÷ (Qh - Qc)- KP
- the coefficient of performance: heat delivered for each unit of work
- Qh
- the heat given to the warm side, in kJ
- Qc
- the heat taken from the cold side, in kJ
In plain words. The machine takes heat from the cold side and adds the work it is given. All of it lands on the warm side. So the work equals the difference of the two heats. Divide the heat you wanted by the work you paid for to get the score.
Worked example. Qh = 100 kJ (assumed) and Qc = 98 kJ (assumed). KP = 100 ÷ (100 - 98) = 50 (calculated) [10], the size GenLess reports for MVR at a lift of around 5 °C [12].
- 2 Science Hard limit
What it gives. The second law: heat does not flow from cold to warm unless work pushes it.
The idea. The best ratio of heat delivered to work depends only on the two temperatures in kelvin, and it falls as the lift grows (reading of the equation in [10]). Energy Innovation says heat pump efficiency declines when providing larger temperature increases, and its model assumes a COP of 3.7 below 100 °C and 2.2 from 100 to 200 °C [11].
The limit. No machine can beat the Carnot ratio, the warm temperature divided by the gap between warm and cold, in kelvin [10].
What could unlock it. Use the smallest possible lift: warm waste heat as the source, or vapour already at process temperature as in MVR [12].
Shr Shared and district heat reuseGSH Geothermal direct use and ground-source heat pumps
Show the maths
KP = Th ÷ (Th - Tc)- KP
- the best heat delivered for each unit of work, a ratio
- Th
- the warm side temperature, in kelvin (degrees Celsius plus 273)
- Tc
- the cold side temperature, in kelvin (degrees Celsius plus 273)
In plain words. Lifting heat up a small hill takes little work and up a big hill takes a lot. The hill is the gap between the cold and warm temperatures. The smaller the gap, the more heat you move for each unit of work.
Worked example. Source heat at 80 °C and delivery at 100 °C (both assumed): Tc = 353 K, Th = 373 K. KP = 373 ÷ (373 - 353) = 18.65 (calculated) [10]. Real machines do worse; the modelled COP of 3.7 in [11] is for a different, larger lift and is not a like-for-like comparison.
- 3 Engineering Soft limit
What it gives. Compressors and heat exchangers that lift process heat, or compress vapour from an evaporator and reuse it.
The idea. GenLess says the MVR cycle can be considered an open cycle heat pump, and that the temperature increase for a single stage is usually up to 10 °C, with manufacturers using up to 8 blowers in series [12]. Energy Innovation says heat pumps reaching around 90 °C are already commonly commercially available in India; at output temperatures of 165 °C for commercial models and 200 °C for pilot-stage models the COP remains around 1.5 [11].
The limit. A single stage lifts only a few degrees, and the final concentration of a liquid can need more than one stage can give [12].
What could unlock it. Stage the blowers in series, as GenLess describes [12], or use a higher-temperature heat pump where the lift is larger [11].
- 4 Production Soft limit
What it gives. Compressors, heat exchangers and packaged units made in volume.
The idea. The IEA says key upstream components, notably rotary compressors, are mostly produced in China, making the supply chain vulnerable to disruption [4]. In India, Energy Innovation names Thermax and Promethean Energy as providers of heat pumps reaching around 90 °C [11].
The limit. Energy Innovation says heat pumps in the higher temperature ranges would have a large addressable market and very few competitors [11].
What could unlock it. The report recommends incentivising domestic manufacturing of electric industrial heating equipment [11].
- 5 Economics Soft limit Binds most today
What it gives. Heat at a price that beats a coal or gas boiler once capital and power are counted.
The idea. In Energy Innovation's model for the band below 100 °C, a grid-powered heat pump costs Rs 2.58 per kWh of heat against Rs 2.59 for a coal boiler, with a COP of 3.7 and grid power at the retail rate of Rs 7.81 per kWh [11]. From 100 to 200 °C, a heat pump on captive renewable power costs Rs 2.68 against Rs 2.65 for a coal boiler [11]. The IEA says equipment and installation costs are substantially higher [13].
The limit. The margin over a coal boiler is 1 to 3 paise per kWh of heat in both bands (calculated), so a small change in tariff or coal price could flip it (judgement). The report annualises capital over a 26-year lifetime at an 11 percent discount rate and adds a carbon price of US$10 per tonne, but states no price year and does not say whether costs are real or nominal [11].
What could unlock it. Captive renewable power at Rs 4.80 per kWh, against the grid's Rs 7.81, lowers the power term [11].
Show the maths
CRF = i (1 + i)n ÷ [(1 + i)n - 1]- CRF
- the capital recovery factor: the share of the purchase price to be repaid each year
- i
- the yearly interest rate, or cost of capital, as a fraction
- n
- the number of years over which the cost is paid back
In plain words. A heat pump costs more on day one than a boiler. The factor says what share of that price you must set aside each year, with interest, to pay it back over its life. Add the yearly power bill and you have the true yearly cost of the heat.
Worked example. i = 11% and n = 26 years, the values in Energy Innovation's model [11]. CRF = 0.11 × 1.1126 ÷ (1.1126 - 1) = 0.11 × 15.08 ÷ 14.08 = 0.118 (calculated) [14]. Each rupee of heat pump capital costs about Rs 0.118 a year (calculated). Power adds Rs 7.81 ÷ 3.7 = Rs 2.11 per kWh of heat (calculated) [11], most of the Rs 2.58 total.
- 6 Resources and rules Soft limit
What it gives. Permission and a grid and tariff structure that let a factory switch to electricity.
The idea. The IEA says commercially available industrial heat pumps could technically already supply up to around 20% of industrial heat demand globally, yet under current policies uptake remains broadly stagnant to 2035 [4]. It says about 75% of heat demand in less energy-intensive industries, such as food processing, textiles and machinery, is below 200 °C [13].
The limit. The rule that binds is the industrial tariff: grid electricity is typically expensive for industrial firms, which partially cross-subsidise residential and agricultural tariffs [11].
What could unlock it. Captive renewable supply [11]; tariff reform would be the other lever (judgement).
as of 2026-11-24
Sources
- Heat Pump Monitor 2026: Key findings IEA, 2026
- The Carnot Cycle (University Physics Volume 2, section 4.5) OpenStax, 2016
- Electrifying Industrial Heat in India Energy Innovation, 2026
- Mechanical vapour recompression for evaporation, distillation, drying (Technical Information Document, July 2019) Energy Efficiency and Conservation Authority (GenLess), New Zealand Government, 2019
- Can low-temperature heat in factories be electrified competitively? (commentary, undated; 2024 cost data) IEA
- Simple levelized cost of energy (LCOE) calculator documentation National Laboratory of the Rockies (formerly NREL), US Department of Energy, 2026