Material Insights · Understanding the Material World

LNG cold and cryogenic recovery: Energy footprint

Energy in use

The energy it uses or converts while it works, and how efficiently

Consumption
None directly; it uses the cold of LNG that vaporisers would otherwise release [3]
Conversion
LNG cold to electricity (Rankine loop), to cooling for air liquefaction, or to direct cooling
Efficiency
23
Unit
kWh of electricity per tonne of LNG, propane Rankine cycle [2]
Note
Chilling gas turbine intake air can use up to 180 kWh of cold per tonne, but that is cooling, not electricity [2].

as of 2026-11-12

Energy links

The energy sources and technologies it uses, holds, converts, loses or gets back

Recovers
  • LNG LNG chain Recovers the cold given off when LNG is regasified, up to 110 MW at a typical terminal [1].
Converts
  • El Electricity The 1979 Osaka Gas plant was claimed to give 1,450 kW from LNG cold [3].

as of 2026-11-12

Sources

  1. Cold energy extracts value from the LNG supply chain (trade report, 2016) Riviera Maritime Media, 2016
  2. Utilization of Cold Energy in Intermediate Fluid-type Vaporizer (IFV) for LNG Receiving Terminals Kobelco Technology Review No. 39 (Suzuki, Egashira, Sumida, Kobe Steel), 2021
  3. Utilization of Cold Energy from LNG Regasification Process: A Review of Current Trends Processes 11(2), 517 (Akashah, Mohammad Rozali, Mahadzir, Liew), MDPI, 2023