Passive solar and natural cooling: Efficiency

Measured by what machines you no longer need

What this tab covers How much of the energy available is actually captured or extracted, in per cent: theoretical limits, laboratory records, typical new equipment and in-service averages, each with exactly what is being measured.

Passive design is judged by how much machine heating, cooling and lighting it avoids rather than by a conversion efficiency. Passive cooling measures can cut a building's cooling energy by 25-40%, evaporative coolers use about a quarter of the electricity of air conditioning, and a measured Trombe wall supplied a fifth of a building's heating.

Chart: Efficiency ranges

Commercial In service

Efficiency by measure

MeasureRangeTypeWhat is measured
Window glass transmittance84 to 95%1CommercialSunlight passing through one pane: standard glass 0.84, low-iron 0.91, anti-reflective 0.95
Cooling energy saved by passive techniques25 to 40%2In serviceReduction in a building's cooling energy from shading, insulation, ventilation and similar measures
Evaporative cooler effectiveness70 to 95%3CommercialHow far air is cooled towards the wet-bulb temperature: aspen pads about 70%, thick media 75-93%, two-stage indirect/direct units 95% or more
Electricity of evaporative coolers relative to central air conditioning25%3CommercialAbout one quarter of the energy for the same cooling job
Trombe wall efficiency, Zion National Park Visitor Center13%6In serviceHeat delivered indoors divided by sunlight striking the wall, 2001-2002 heating season; the wall supplied 20% of the building's heating
Electricity saved by seawater air conditioning83 to 94.5%5CommercialFeasibility estimates for Grenada, Jamaica and the Dominican Republic against chillers

Where the energy is lost

StepLoss
Evaporative cooling in humid airtemperature drop falls from 27 F (15 C) at 10% humidity to 11 F (6 C) at 50% humidity (Celsius calculated)3
Window glass reflects and absorbs sunlight5-16% per pane (calculated)1

Glazing and thermal mass collect and store solar heat, so their benefit depends on climate and use. Cooling measures exploit natural heat sinks: evaporating water (only in dry air), the cold night sky, the stable temperature of the ground and cold deep seawater. They are best compared with the electricity an air conditioner would otherwise use. Measures in other units (earth-tube air warming in degrees, radiative cooling in watts per square metre) are given under Techniques.

Sources

  1. Solar Collectors (workshop lecture, W. Weiss, AEE INTEC) Centre for Renewable and Sustainable Energy Studies, Stellenbosch University, 2013
  2. Buildings Decarbonisation Report: Summary, Cooling Energy Transitions Commission, 2025
  3. Evaporative Cooling Systems (Building America Solution Center) Pacific Northwest National Laboratory / US Department of Energy, 2024
  4. Sustainable cooling: a deep dive into seawater air-conditioning solutions for the Caribbean World Bank Blogs, 2024
  5. Trombe Walls in Low-Energy Buildings: Practical Experiences (Torcellini and Pless, NREL/CP-550-36277) National Renewable Energy Laboratory, 2004