Passive solar and natural cooling: Resources and labour

Ordinary materials, clever placement, and some water

What this tab covers The natural resources (land, water, materials, fuel or feedstock) and the labour needed to capture this energy, per unit, with the reason each is needed.

Passive techniques mostly use ordinary building materials arranged with care. The main exceptions are water for evaporative coolers and deep-water pipelines for seawater cooling. No per-unit job figures were found.

Natural resources

ResourceHow muchWhy it is needed
Thermal mass (masonry, concrete, earth, water)20 cm of concrete masonry in the Zion Trombe wall, delaying heat by 8-10 hours6Dense materials store much heat per degree, smoothing heat flows between day and night.
GlassTransmits 84-95% of sunlight per pane1Admits sunlight while blocking the longer-wave infrared emitted indoors.
Water (evaporative coolers)About 2,980-12,457 gallons (11-47 m3, calculated) a year for a 1,500 square foot New Mexico home; bleed-off adds 10-50%3Cooling comes from evaporation; bleed-off flushes out minerals.
Air movement20-40 air changes per hour for evaporative systems3Large air volumes must carry heat away.
Deep cold water and pipelines (seawater cooling)Intake about 900 m deep; USD 16.5-70 million per project5Only deep water is cold enough to chill buildings directly.
Reflective coatings (radiative cooling)About 97% solar reflectance4Any sunlight absorbed would outweigh the small heat radiated to the sky.

Labour

PhaseHow muchSkillsWhy it is needed
DesignNo figure in the sources used2Architects and building-physics engineersOrientation, windows and shading fix passive performance at the design stage.
ConstructionNo figure in the sources used5Masons, glaziers, carpenters; marine engineers for seawater systemsShading and thermal mass depend on careful building work.
Operation and maintenanceEvaporative pads flushed every 8-12 operating hours (auto-flush)3Building users and maintenance staffPads clog with minerals; occupants must open and shade windows at the right times.

Sources

  1. Solar Collectors (workshop lecture, W. Weiss, AEE INTEC) Centre for Renewable and Sustainable Energy Studies, Stellenbosch University, 2013
  2. Buildings Decarbonisation Report: Summary, Cooling Energy Transitions Commission, 2025
  3. Evaporative Cooling Systems (Building America Solution Center) Pacific Northwest National Laboratory / US Department of Energy, 2024
  4. Passive radiative cooling below ambient air temperature under direct sunlight (Raman, Anoma, Zhu, Rephaeli and Fan, Nature 515, 540-544) Nature, 2014
  5. Sustainable cooling: a deep dive into seawater air-conditioning solutions for the Caribbean World Bank Blogs, 2024
  6. Trombe Walls in Low-Energy Buildings: Practical Experiences (Torcellini and Pless, NREL/CP-550-36277) National Renewable Energy Laboratory, 2004