Structures and materials: stress, stiffness, strength and why things break: Key terms, quiz and sources
All courses / Understanding Engineering / Module 4: Structures and materials: stress, stiffness, strength and why things break Wrap-upStructures and materials: stress, stiffness, strength and why things break: review
Key terms
- Load path
- The route by which weight and other loads pass through slab, beam, column and footing to the ground.
- Dead load and live load
- Dead load is the permanent weight of a structure; live load is the changing weight of people and contents.
- Tension, compression, shear and bending
- The ways a member can be loaded: pulled, squeezed, slid across itself, or bowed with one face stretched and one squeezed.
- Stress
- Force per unit area inside a material, measured in pascals or megapascals (newtons per square millimetre).
- Strain
- The fractional change in length of a loaded material, a pure number.
- Young's modulus
- The stress needed per unit of strain in the elastic range: a measure of a material's stiffness, about 200 GPa for steel.
- Yield strength
- The stress at which a material starts to deform permanently.
- Ductility
- How far a material can stretch before it breaks, which gives visible warning of failure.
- Toughness
- The energy a material absorbs before breaking, shown by the area under its stress-strain curve.
- Second moment of area
- A property of a cross-section that measures how far its material lies from the middle and so sets its resistance to bending.
- Buckling
- Sideways collapse of a slender member in compression, at a load set by stiffness and length rather than by crushing strength.
- Truss
- A frame of straight members joined in triangles so that each carries only pull or squeeze.
- Reinforced concrete
- Concrete with steel bars placed where the concrete would be stretched.
- Prestressed concrete
- Concrete squeezed in advance by tensioned high-strength steel so that loads cannot easily crack it.
- Creep
- Slow, continuing deformation of a material under a steady load.
- Fracture toughness
- A material's resistance to the growth of a crack, measured in MPa times the square root of metres.
- Fatigue
- Progressive cracking caused by many repeated loads that are each below the material's strength.
- Corrosion
- The chemical attack of a metal by its surroundings, such as rusting of steel, which thins the metal over time.
- Factor of safety
- The ratio of the load that would cause failure to the load expected in service, a margin for uncertainty.
Try it in the table
- Open 'Reinforced concrete' and 'Steel reinforcing bar'. Take the bar mass per metre on the site and check it against 7,850 kg/m3 x the area of a 12 mm bar (113 mm2). Then work out the yield force of one 12 mm Fe500 bar, 500 MPa x 113 mm2, and say how many tonnes-force it holds.
- Look at 'Prestressed concrete' and 'Precast concrete products'. Find a girder or slab and guess its cross-section area. Using 20 strands as in estimate 9, work out the average squeeze in the concrete, and say whether it stays well under the concrete's compressive strength.
- Open 'Cable-stayed bridge' and 'Iron suspension bridge'. For a bridge you know, guess the height of a tower and the spacing of its stays. Estimate the angle and use tension = load / sine(angle) to see how much steel one stay needs.
- In 'Steel-frame skyscraper' and 'Iron-framed building', pick a building of 20 floors. Using 6 kN/m2 and a column bay of 6 m x 6 m, find the load at the base of one column, and compare it with the yield force of a steel section of 0.02 m2 at 250 MPa.
- Open 'Steel', 'Aluminium' and 'Timber'. Take a density and a strength from the pages, and compute strength divided by density, as in the materials table. Which would you pick for a light footbridge, and which for a 40 m span?
- Read 'Passivation and corrosion resistance' and 'Stainless steel'. Using the corrosion table in this module, estimate how many wires of a 49-wire cable can be lost before a factor of safety of 3 falls to 1.5.
Final quiz
In the load path of an Indian flat block, which order is correct from the floor to the soil?
The slab leans on beams, beams on columns, columns on footings, and footings on soil. Each handover must hold, or the chain fails at that link.Two steel bars, one of Fe415 and one of Fe550, have the same size and carry the same small pull. How do their stretches compare?
Both have a Young's modulus near 200 GPa. Grade changes strength, not stiffness, so below yield their stretch is nearly equal.A mild steel bar and a ceramic rod of the same size are hit with a hammer. Why does the steel survive?
Toughness is energy absorbed before fracture. Steel's long plastic range gives it a very large area under the stress-strain curve, while a ceramic breaks near the end of its elastic line.A floor beam sags too much but is strong enough. Which change is the most effective?
Sag depends on E x I. A deeper section raises I with the cube of depth, while a higher yield strength leaves E unchanged.In a hollow tube compared with a solid rod of the same steel mass, what is gained?
Moving material outwards increases the second moment of area, and so bending stiffness and buckling load, for the same mass. The limit is local wrinkling of a very thin wall.Which three facts together make steel and concrete work as a pair?
Ribbed bars grip concrete, the two expand by similar amounts when warmed, and the lime-rich pore water forms a protective film on the steel. Their densities and stiffnesses differ widely.A cable carries a vertical load of 1,000 kN at 20 degrees to the horizontal (sine 0.34). About what is its tension?
Tension = load / sine of the angle = 1,000 / 0.34, about 2,900 kN. Flat cables carry far more tension than the load they hold up.What is the lesson of fatigue for a bridge detail that sees 90 million truck passes?
Each cycle grows a crack a tiny amount. Over tens of millions of cycles, welds and corners with high stress concentration reach critical size even though no single load was close to the strength.Sources for this module
- Kosky et al., Exploring Engineering (Academic Press, 2013) · ch. 11, 'Materials Engineering' (stress, strain, elastic modulus, yield strength, toughness, selection of materials); ch. 12, 'Mechanical Engineering' (elements of machine design)
- Bloomfield, How Things Work (Wiley, 2015) · ch. 1, 'The Laws of Motion, Part 1' (weight, forces, equilibrium); ch. 3, 'Mechanical Objects, Part 1' (Hooke's law, elastic limit, bending floors)
- Petroski, To Engineer Is Human (Macmillan, 1985) · ch. 3, 'Lessons from Play; Lessons from Life' (fatigue); ch. 8, 'Accidents Waiting to Happen'; ch. 9, 'Safety in Numbers' (factor of safety); ch. 10, 'When Cracks Become Breakthroughs'; ch. 11, 'Of Bus Frames and Knife Blades'; ch. 13, 'The Ups and Downs of Bridges'
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. II (Caltech online edition) · further reading: ch. 38, 'Elasticity', https://www.feynmanlectures.caltech.edu/II_38.html; ch. 39, 'Elastic Materials', https://www.feynmanlectures.caltech.edu/II_39.html
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 12, 'Characteristics of Force', https://www.feynmanlectures.caltech.edu/I_12.html
- Bureau of Indian Standards, IS 875 (Part 2):1987, Imposed loads · table 1, imposed floor loads; https://law.resource.org/pub/in/bis/S03/is.875.2.1987.pdf
- Bureau of Indian Standards, IS 456:2000, Plain and reinforced concrete · cl. 5.6.3, 6.2.2, 6.2.5.1, 23.2, 26.4 (table 16), 26.5.1.1, 36.4.2, 38.1 and table 18; https://law.resource.org/pub/in/bis/S03/is.456.2000.pdf
- Bureau of Indian Standards, IS 800:2007, General construction in steel · E = 200,000 MPa, Euler buckling stress (cl. 7.1.2.1), deflection limits (table 6); figures as commonly summarised, not read from the code
- Bureau of Indian Standards, IS 1343:2012, Prestressed concrete, and IS 14268, Uncoated stress-relieved low-relaxation seven-ply strand · 15.2 mm strand of 140 mm2 and 1,860 MPa, modulus about 195 GPa; figures as commonly summarised, not read from the codes
- Bureau of Indian Standards, IS 1786:2008, High strength deformed steel bars · grades Fe415 to Fe550D; minimum elongation 12 per cent for Fe500 and 16 for Fe500D, as commonly summarised; Fe550 and Fe550D table on Tata Steel's Tiscon 550SD page, https://readybuild.tatasteel.com/content/readybuild/tata-tiscon-550-sd.html
- Aerospace Specification Metals, 'Aluminum 6061-T6' data sheet, citing the Aluminum Association · E 68.9 GPa, yield 276 MPa, density 2.70 g/cm3; https://www.aerospacemetals.com/wp-content/uploads/2023/06/Aluminum-6061-T6-6061-T651.pdf
- Toray Composite Materials America, 'T700S' data sheet · fibre 230 GPa, 1.80 g/cm3; composite at 60 per cent fibre 134 GPa, 2,860 MPa; https://www.toraycma.com/wp-content/uploads/T700S-Data-Sheet.pdf
- USDA Forest Products Laboratory, Wood Handbook: Wood as an Engineering Material (FPL-GTR-190, 2010) · ch. 5, table 5-3a: oak modulus of elasticity about 12 GPa and compression along the grain about 45 to 50 MPa at 12 per cent moisture
- TWI Ltd, 'Schenectady T2 tanker' (read November 2026), summarising the 1946 US Board of Investigation · 4,694 welded ships, 970 with fractures; notch-sensitive steel; https://www.twi-global.com/media-and-events/insights/schenectady-t2-tanker
- Aerossurance, 'Common Comet Misconceptions and Collaborative Contribution to Safety' (read November 2026), summarising the Court of Inquiry report CAP 127 (1955) · G-ALYP 35 dead, G-ALYY 21 dead; ADF cut-out origin; G-ALYU tank test failure after 3,060 cycles; 1956 BCAR fatigue-test rule; https://aerossurance.com/safety-management/comet-misconceptions/
- Press Trust of India, 'Corroded wires, welded suspenders behind Morbi bridge tragedy: SIT report', Business Standard (19 February 2023) · web
- US Code of Federal Regulations, 14 CFR 25.303, 'Factor of safety' · ultimate load = 1.5 x limit load for transport aircraft
- CEN, EN 81-20:2020, Safety rules for the construction and installation of lifts · minimum safety factor of suspension ropes (12 for traction drive with three or more ropes)