| Year | Event |
|---|---|
| 1958 | Ake Senning implants Rune Elmqvist's pacemaker, a disc 55 mm across in epoxy resin that runs on two nickel-cadmium cells and lasts only a few hours [5] |
| 1958 | Medtronic's first pacemaker, the wearable 5800, becomes commercially available [7][8] |
| 1960 | Chardack, Greatbatch and Gage report the first long-term implant of a self-contained, internally powered pacemaker [19]; in October Medtronic signs for exclusive rights to produce and market it, production begins a month later [7], and 50 orders arrive in the last two months of the year [21] |
| 1972 | Greatbatch and his team invent the lithium iodine battery [3]; the first lithium iodide battery powered pacemaker and the first hermetically sealed pacemaker follow the same year [8] |
| 2009 | A world survey counts 1,002,664 pacemakers from 61 countries [4] |
| 2016 | The FDA approves the Medtronic Micra leadless pacemaker on 6 April [6] |
as of 2026-11-13
Lineage
The products and technologies it evolved from and into
Evolved from- Pcm Implantable pacemaker The twin technology page holds the working principle; this node covers the device as goods.
as of 2026-11-13
Recipe changes
How what it is made of changed over time, and what drove each change
| Change | From | To | Driver | Source |
|---|---|---|---|---|
| Battery | Rechargeable nickel-cadmium cells (1958), then zinc-mercury batteries that worked for over two years | Lithium iodine battery (invented 1972), lasting about 10 years | Longer life between replacement operations [5][3] | [5][3] |
| Case | Disc encased in epoxy resin (1958) | Hermetically sealed titanium alloy case, a technique pioneered by Cardiac Pacemakers, Inc. (first sealed pacemaker 1972) | The sources opened give no stated reason beyond hermetic sealing [5][8] | [5][8] |
| Mass | About 180 g (first implantable pacemaker) | About 30 g for modern devices (2014 review); 1.75 g for a leadless model | Smaller electronics and batteries; leadless designs drop the leads [3][2] | [3][2] |
as of 2026-11-13
What could improve it next
Directions for improvement, today's value and the limit
| Direction | Metric | Today | Unit | Source |
|---|---|---|---|---|
| Smaller leadless devices | Mass of a leadless pacemaker (Micra) | 1.75 | g | [2] |
| Longer battery life, fewer replacement operations | Battery longevity of the Micra AV2, high end (maker's table value) | 13 | years | [2] |
as of 2026-11-13
Sources
- Micra AV and Micra VR leadless pacemakers for bradyarrhythmia management Medtronic (India site), 2024, specification table; page footer says last updated March 2024
- A Look Back: 85 Years of Cardiac Pacing EP Lab Digest (HMP Global Learning Network), B. J. Wilhelm and B. Osswald, 2014, September 2014
- The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009 - a World Society of Arrhythmia's project Pacing and Clinical Electrophysiology (Mond and Proclemer), on PubMed, 2011, abstract
- The First Inkjet Printer Was a Medical Device IEEE Spectrum, 2025, 28 August 2025
- Premarket Approval (PMA): Medtronic Micra Transcatheter Pacemaker System, P150033 US Food and Drug Administration, Decision Date 04/06/2016; applicant Medtronic, Inc.
- Medtronic Minnesota Historical Society (MNopedia), chronology entries for 1958 and 1960; no author or page date shown
- Pacemakers Engineering and Technology History Wiki, 2017, timeline and text; page last edited 23 November 2017
- Greatbatch, Chardack & Gage Implant the First Self-Contained Internally Powered Artificial Pacemaker in a Human historyofinformation.com, entry dated 1960 to 12/9/2013
- Medtronic, Inc. Encyclopedia.com (International Directory of Company Histories), company history text; no year shown