Cardiac pacemaker: Use case
Use cases
Each use, its share of demand and volume, how critical the product is to it and why, and the price paid
| Use case | Share of demand | Volume | Unit | Criticality | Reason | Year | Source |
|---|---|---|---|---|---|---|---|
| New pacemaker implants (first device), 2009 world survey of 61 countries; share calculated from the survey counts | 73.6% | 737,840 | pacemakers | Essential | A pacemaker is described as able to save lives [13], and none of the sources opened names another device for the same job; reconditioned pacemakers are the same product, not a substitute. | 2009 | [4][13] |
| Replacement of a pacemaker at its battery's replacement time, same survey; share calculated from the survey counts | 26.4% | 264,824 | pacemakers | Essential | The maker's manual says that when the replacement time has been reached the pacemaker must be replaced [1]. | 2009 | [4][1] |
as of 2026-11-13
Industries that buy it
The industries and kinds of firm that buy it, for which use case, and how critical it is to them
Used by- Hospitals and specialty hospital chains Implanting pacemakers and replacing generators · criticality essential The 2009 survey counted 1,002,664 pacemaker implants, new and replacement, across 61 countries [4]; essential because no source opened names another device for the job [13].
as of 2026-11-13
How it is used
Lifetime, use per year and utilisation, by variant
| Measure | Value | Unit | Variant | Place | Year | Source |
|---|---|---|---|---|---|---|
| Typical life of a lithium iodine pacemaker battery, about (2014 review) | 10 | years | Transvenous | World | 2014 | [3] |
| Average service time precalculated by BIOTRONIK for the Evia DR-T at 3.0 V, 500 ohm, 100% pacing and a basic rate of 60 ppm (manual service time table value) | 8.5 | years | Transvenous | World | 2009 | [1] |
| Battery longevity of the Micra AV2, low end; the high end is 13 years (maker's table values; footnotes give the pacing assumptions) | 8 | years | Leadless | World | 2024 | [2] |
| New pacemaker implants per million people, highest country in the 2009 survey | 927 | per million people (Germany) | – | Germany | 2009 | [4] |
| Pacemaker implants a year in low-income countries, as stated in the AHA release on the study (upper bound) | 3 | per million people or fewer | – | World | 2024 | [13] |
| Pacemaker implants a year in some high-income countries, as many as (AHA release on the study) | 1000 | per million people | – | World | 2024 | [13] |
as of 2026-11-13
Prices
Unit prices by market or use, with year and source
| Market | Value | Unit | Year | Source |
|---|---|---|---|---|
| India, CGHS ceiling rate, single chamber pacemaker without rate response (excluding GST; as reported by a trade site) | 34,840 | INR | 2018 | [15] |
| India, CGHS ceiling rate, dual chamber pacemaker (excluding GST; as reported by a trade site) | 83,200 | INR | 2018 | [15] |
| India, CGHS ceiling rate, bi-ventricular pacemaker (excluding GST; as reported by a trade site) | 195,000 | INR | 2018 | [15] |
as of 2026-11-13
Sources
- BIOTRONIK EVIA User And Technical Manual BIOTRONIK (copy hosted on manualmachine.com), 2009, Doc. Id. 365353-A, cover dated 23.04.2009; mechanical characteristics, battery data and service time tables; explantation and disposal section
- Micra AV and Micra VR leadless pacemakers for bradyarrhythmia management Medtronic (India site), 2024, specification table; page footer says last updated March 2024
- A Look Back: 85 Years of Cardiac Pacing EP Lab Digest (HMP Global Learning Network), B. J. Wilhelm and B. Osswald, 2014, September 2014
- The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009 - a World Society of Arrhythmia's project Pacing and Clinical Electrophysiology (Mond and Proclemer), on PubMed, 2011, abstract
- Reconditioned pacemakers worked as well as new ones American Heart Association newsroom, 2024, dated 17 November 2024; the study abstract was not peer reviewed, as the page says
- CGHS – Ceiling rates for Cardiac Pacemaker, AICD, Combo-device, Rotablator and Aortic Stent Graft GConnect (trade site reporting CGHS Office Memorandum No. S-11011/29/2018-CGHS(HEC)/DIR/CGHS of 6 August 2018), 2018, dated 14 August 2018; CGHS's own copy of the memorandum could not be opened (the site refuses automated access)