Electrolyser: Bill of materials
About these figures
Which unit, study and year the composition figures describe, and how they vary
Alkaline: a 5 MW plant of two stacks, 90,958 kg in Table 2's Mass Total column (stated 90,959), divided by 5 for one MW (calculated), 2025 [8]; several rows do not multiply out, so the column is used as given. PEM: one unit labelled 'Electrolyzer (PEM, 1 MW unit)', 2022 [7]. Not counted: concrete, control electronics (1,100 kg), organic chemicals, activated carbon, plywood, polysulfone and iridium (0.75 kg, no node). No solid oxide inventory was found.
as of 2026-11-13
Components
The products inside one unit, with quantity, mass share and cost share
Variant Alkaline| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| Transformer and power converter | Component | 2.2 | 33.7% |
| The 5 MW alkaline plant has 11 inverters (Table 2), 2.2 per MW (calculated). Their rows (steel 15,818, lubricating oil 9,691, copper 3,685, aluminium 1,441 kg) total 30,635 kg of 90,958 kg, 33.7% by mass (calculated) [8]. These materials are counted only here, not in prod_bom.materials. The PEM inventory lists no separate rectifier. | |||
as of 2026-11-13
Direct materials
The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content
Variant 1 Alkaline| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| St Steel | Structural | 7775 kg | 42.7% |
| Stainless, low-alloyed and chromium steel plus 615 kg of cast iron, outside the inverter: 38,875 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| Ni Nickel | Functional | 2170.6 kg | 11.9% |
| Electrodes, mesh and bipolar plates: 10,853 kg of nickel in the 5 MW plant, plus 42 kg of nickel sulfide on the cathodes. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| EPDM EPDM | Structural | 632.8 kg | 3.5% |
| EPDM rubber gaskets, 3,164 kg in the 5 MW plant (464 gaskets), incinerated at end of life. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| Cu Copper | Functional | 403 kg | 2.2% |
| Copper plates, busbars and pumps, outside the inverter: 2,015 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| LLDPE Polyethylene (LDPE, LLDPE) | Structural | 162.6 kg | 0.9% |
| Separator plates 304, potassium hydroxide tank 362 and control unit and cable 147 kg: 813 kg in the 5 MW plant. Polysulfone (70 kg), plywood housing (3,800 kg) and synthetic rubber (5 kg) have no node and are not counted. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| Zr Zirconium | Functional | 78.8 kg | 0.4% |
| Zirconium oxide in the separator membrane: 394 kg in the 5 MW plant, as oxide. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| Al Aluminium | Structural | 41.8 kg | 0.2% |
| Control unit, outside the inverter: 209 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| PTFE Fluoropolymers (PTFE, PVDF) | Structural | 16.6 kg | 0.09% |
| Polyvinyl fluoride in the control unit and cable, 83 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8]. | |||
| Material | Role | Amount in one unit | Share of the unit's mass |
|---|---|---|---|
| St Steel | Structural | 6800 kg | 74% |
| Stack 100 kg of 18/8 chromium steel, balance of plant 1,900 kg of chromium steel and 4,800 kg of low-alloyed steel (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7]. | |||
| Ti Titanium | Functional | 528 kg | 5.7% |
| Stack plates and porous layers, 528 kg of primary titanium per 1 MW unit; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7]. | |||
| PP Polypropylene | Structural | 300 kg | 3.3% |
| Polypropylene granulate in the balance of plant, 300 kg per 1 MW unit; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7]. | |||
| Al Aluminium | Structural | 127 kg | 1.4% |
| Stack 27 kg and balance of plant 100 kg (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7]. | |||
| Cu Copper | Functional | 104.5 kg | 1.1% |
| Stack 4.5 kg and balance of plant 100 kg (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7]. | |||
| PTFE Fluoropolymers (PTFE, PVDF) | Functional | 13.2 kg | 0.14% |
| Tetrafluoroethylene, the precursor the inventory uses for the membrane polymer; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7]. | |||
| Pt Platinum | Functional | 0.075 kg | 0.001% |
| Platinum catalyst, 0.075 kg per 1 MW unit. The 0.75 kg of iridium in the same stack has no node of its own, so it stays in the notes and is not counted here [7]. | |||
as of 2026-11-13
How it is put together
The main steps from parts and materials to the finished unit
| Step | What happens | Technology | Source |
|---|---|---|---|
| Make the cell parts | Electrodes, separators or membranes, frames and bipolar plates are made and coated with catalyst. | – | [8][7] |
| Stack the cells | Hundreds of cells are pressed between end plates into a stack; Table 2 of the 5 MW alkaline reference lists 232 cells, and most stack totals are twice the per-plant quantity, consistent with 232 cells in each of its two stacks. | – | [8] |
| Build skids | Stacks are mounted on skids with pumps, separators and cooling; a 100 MW PEM project uses 50 skids and 150 stacks. | – | [12] |
| Add power and control | A rectifier, control unit and cabling are added to turn grid power into direct current. | Transformers and power electronics | [8] |
| House and test | The units are placed in a housing or building and tested before commissioning. | – | [8] |
as of 2026-11-13
Technologies inside it
The technologies inside the product, with how much of each per unit
Embodies- Elz Electrolysers 1 MW The electrolysis technology itself.
- PE Transformers and power electronics A rectifier (the inverter rows of the reference) and control unit turn grid power into direct current; the inverters are 33.7% of the alkaline reference mass (calculated) [8].
as of 2026-11-13
Sources
- Large-scale hydrogen production via water electrolysis: a techno-economic and environmental assessment, Electronic Supplementary Information Royal Society of Chemistry (Terlouw, Bauer, McKenna, Mazzotti, Energy & Environmental Science), 2022, Tables A1, A2 and A4
- Reducing Environmental Impacts of Water Electrolysis Systems by Reuse and Recycling: Life Cycle Assessment of a 5 MW Alkaline Water Electrolysis Plant Energies 18(4), 796, MDPI (Annika C. Hoppe and Christine Minke), 2025, Table 2
- Deliverable 9.4, GHG emissions avoidance analysis report (pre-construction) TECNALIA for the REFHYNE 2 project, 2025, Sections 5.1 to 5.3; dated March 2025