Material Insights · Understanding the Material World

Electrolyser: Bill of materials

About these figures

Which unit, study and year the composition figures describe, and how they vary

Alkaline: a 5 MW plant of two stacks, 90,958 kg in Table 2's Mass Total column (stated 90,959), divided by 5 for one MW (calculated), 2025 [8]; several rows do not multiply out, so the column is used as given. PEM: one unit labelled 'Electrolyzer (PEM, 1 MW unit)', 2022 [7]. Not counted: concrete, control electronics (1,100 kg), organic chemicals, activated carbon, plywood, polysulfone and iridium (0.75 kg, no node). No solid oxide inventory was found.

as of 2026-11-13

Components

The products inside one unit, with quantity, mass share and cost share

Variant Alkaline
MaterialRoleAmount in one unitShare of the unit's mass
Transformer and power converterComponent2.233.7%
The 5 MW alkaline plant has 11 inverters (Table 2), 2.2 per MW (calculated). Their rows (steel 15,818, lubricating oil 9,691, copper 3,685, aluminium 1,441 kg) total 30,635 kg of 90,958 kg, 33.7% by mass (calculated) [8]. These materials are counted only here, not in prod_bom.materials. The PEM inventory lists no separate rectifier.

as of 2026-11-13

Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content

Variant 1 Alkaline
MaterialRoleAmount in one unitShare of the unit's mass
St SteelStructural7775 kg42.7%
Stainless, low-alloyed and chromium steel plus 615 kg of cast iron, outside the inverter: 38,875 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
Ni NickelFunctional2170.6 kg11.9%
Electrodes, mesh and bipolar plates: 10,853 kg of nickel in the 5 MW plant, plus 42 kg of nickel sulfide on the cathodes. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
EPDM EPDMStructural632.8 kg3.5%
EPDM rubber gaskets, 3,164 kg in the 5 MW plant (464 gaskets), incinerated at end of life. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
Cu CopperFunctional403 kg2.2%
Copper plates, busbars and pumps, outside the inverter: 2,015 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
LLDPE Polyethylene (LDPE, LLDPE)Structural162.6 kg0.9%
Separator plates 304, potassium hydroxide tank 362 and control unit and cable 147 kg: 813 kg in the 5 MW plant. Polysulfone (70 kg), plywood housing (3,800 kg) and synthetic rubber (5 kg) have no node and are not counted. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
Zr ZirconiumFunctional78.8 kg0.4%
Zirconium oxide in the separator membrane: 394 kg in the 5 MW plant, as oxide. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
Al AluminiumStructural41.8 kg0.2%
Control unit, outside the inverter: 209 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
PTFE Fluoropolymers (PTFE, PVDF)Structural16.6 kg0.09%
Polyvinyl fluoride in the control unit and cable, 83 kg in the 5 MW plant. Per MW is the Table 2 'Mass Total' column for the 5 MW plant divided by 5 (calculated); several rows do not multiply out (most stack rows are twice mass per part times quantity, consistent with two stacks; nickel sulfide, membrane and one control-unit row are not) [8].
Variant 2 PEM
MaterialRoleAmount in one unitShare of the unit's mass
St SteelStructural6800 kg74%
Stack 100 kg of 18/8 chromium steel, balance of plant 1,900 kg of chromium steel and 4,800 kg of low-alloyed steel (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7].
Ti TitaniumFunctional528 kg5.7%
Stack plates and porous layers, 528 kg of primary titanium per 1 MW unit; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7].
PP PolypropyleneStructural300 kg3.3%
Polypropylene granulate in the balance of plant, 300 kg per 1 MW unit; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7].
Al AluminiumStructural127 kg1.4%
Stack 27 kg and balance of plant 100 kg (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7].
Cu CopperFunctional104.5 kg1.1%
Stack 4.5 kg and balance of plant 100 kg (sum calculated); mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7].
PTFE Fluoropolymers (PTFE, PVDF)Functional13.2 kg0.14%
Tetrafluoroethylene, the precursor the inventory uses for the membrane polymer; mass share of the 9,185 kg listed in kilograms, concrete excluded (calculated) [7].
Pt PlatinumFunctional0.075 kg0.001%
Platinum catalyst, 0.075 kg per 1 MW unit. The 0.75 kg of iridium in the same stack has no node of its own, so it stays in the notes and is not counted here [7].

as of 2026-11-13

How it is put together

The main steps from parts and materials to the finished unit

StepWhat happensTechnologySource
Make the cell partsElectrodes, separators or membranes, frames and bipolar plates are made and coated with catalyst.– [8][7]
Stack the cellsHundreds of cells are pressed between end plates into a stack; Table 2 of the 5 MW alkaline reference lists 232 cells, and most stack totals are twice the per-plant quantity, consistent with 232 cells in each of its two stacks.– [8]
Build skidsStacks are mounted on skids with pumps, separators and cooling; a 100 MW PEM project uses 50 skids and 150 stacks.– [12]
Add power and controlA rectifier, control unit and cabling are added to turn grid power into direct current.Transformers and power electronics[8]
House and testThe units are placed in a housing or building and tested before commissioning.– [8]

as of 2026-11-13

Technologies inside it

The technologies inside the product, with how much of each per unit

Embodies
  • Elz Electrolysers 1 MW The electrolysis technology itself.
  • PE Transformers and power electronics A rectifier (the inverter rows of the reference) and control unit turn grid power into direct current; the inverters are 33.7% of the alkaline reference mass (calculated) [8].

as of 2026-11-13

Sources

  1. Large-scale hydrogen production via water electrolysis: a techno-economic and environmental assessment, Electronic Supplementary Information Royal Society of Chemistry (Terlouw, Bauer, McKenna, Mazzotti, Energy & Environmental Science), 2022, Tables A1, A2 and A4
  2. Reducing Environmental Impacts of Water Electrolysis Systems by Reuse and Recycling: Life Cycle Assessment of a 5 MW Alkaline Water Electrolysis Plant Energies 18(4), 796, MDPI (Annika C. Hoppe and Christine Minke), 2025, Table 2
  3. Deliverable 9.4, GHG emissions avoidance analysis report (pre-construction) TECNALIA for the REFHYNE 2 project, 2025, Sections 5.1 to 5.3; dated March 2025