Material Insights · Understanding the Material World

Insulating glass unit: Working

What it is

The product and the job it does, in a short paragraph

An insulating glass unit (IGU) is two or three panes of glass held apart by an edge spacer and sealed around the rim, so that the gap holds air or argon [10][1]. It slows heat flow through windows, facades and glazed doors. This file covers double units (air-filled and argon low-e) and triple units, classed as HS 7008. The functional unit is one square metre of double-glazed unit, for example 4-16-4 mm (4 mm glass, 16 mm gap, 4 mm glass) [1].

as of 2026-11-16

How it works

How it does its job, step by step in plain words

Heat crosses a window by conduction, by moving gas in the gap, and by infrared radiation between the panes. The sealed gap traps still gas, which lowers conduction [10]. A thin low-emissivity (low-e) coating on one pane, often silver, reflects long-wave infrared heat back to where it came from [35][10]. Argon, which is heavier than air, slows the moving-gas loop, and with 90% argon in a low-e unit it improves insulation by about 16% [30][39]. A spacer bar holds the panes apart and houses a desiccant, a drying agent, that keeps the gap dry [15]. The gas slowly escapes through the edge seal [30]. A metal spacer conducts heat at the edge, so stainless steel or non-metal 'warm edge' spacers are used [30]. The AGC 4-16-4 unit has a centre-of-glass U-value of 1.0 to 1.1 W/m2K [1].

as of 2026-11-16

Key specifications

The numbers that describe it, each with unit, variant, year and source

SpecValueUnitVariantYearSource
Mass per m2, 4-16-4 mm unit20kg per m2 (glass only; about 20.6 with spacer, seals and fill, calculated)Argon low-e double2019[1]
Mass per m2, 4/12/4/12/4 mm unit31kg per m2Triple2023[2]
Centre-of-glass U-value (Ug), single glass for comparison5.8W/m2K– 2019[3][9]
Centre-of-glass U-value (Ug), uncoated double2.9W/m2KAir-filled double2019[3]
Centre-of-glass U-value (Ug), coated double1.3W/m2KArgon low-e double2019[3]
Centre-of-glass U-value (Ug), triple0.7W/m2KTriple2019[3]
Solar factor (g-value), uncoated double / coated double / triple0.77 / 0.62 / 0.5fraction– 2019[3]
Reference service life used in EPDs30years– 2019[1][2]

as of 2026-11-16. TNO takes its glazing values from Glass for Europe, an industry body [3]. AGC's declaration gives 1.0 to 1.1 W/m2K for its low-e unit [1]; Glass for Europe gives about 1.0 to 1.4 for high-performance double and 0.5 to 0.9 for triple glazing [27].

Variants

The variants whose make-up or footprint differs a lot, what defines each and its share of units

VariantDefining specYearSource
Air-filled doubleTwo panes, air in the gap, no low-e coating; Ug about 2.9 W/m2K, g-value 0.77 [3]2019[3]
Argon low-e doubleTwo panes, one with a low-e coating, argon in the gap; Ug 1.0 to 1.1 W/m2K, 20 kg of glass per m2 [1]2019[1]
TripleThree panes, two coated, two argon gaps; Ug about 0.7 W/m2K, 31 kg per m2 [3][2]2023[3][2]

as of 2026-11-16. No source gives sales by variant. Double glazed units were about 73% of the 2025 world market by value, USD 21.54 billion of 29.50 billion (calculated) [17].

Limits

The physical limits set by science and the engineering limits of today's design, with today's value

LimitKindLimitTodayUnitSource
Solar control: lowest solar heat gain (SHGC) while still passing about 60% of visible lightPhysical0.250.33SHGC at visible transmittance (VLT) of about 0.6 to 0.66[8]
Centre-of-glass U-value of commercial glazing, set by gas fills, coatings and number of panesEngineering0.250.5 to 1.4W/m2K (0.25 is TNO's projected 2030 to 2050 glazing family)[3][4]
Gap width at which argon performs wellEngineering12.712 to 16mm (half an inch is calculated as 12.7 mm)[10][1][2]

as of 2026-11-16. The 0.25 solar limit is a figure from TERI for glass that still lets in daylight; the best glass TERI cites has a VLT of 0.66 and SHGC of 0.33 [8].

Science it relies on

The science principles it works by or is limited by

Relies on Limited by
  • Blackbody radiation Sunlight and room heat sit in different wavelength bands, which sets how well one coating can pass light but block heat.

as of 2026-11-16

Sources

  1. Environmental Product Declaration: Low-e/solar control double glazing units (Thermobel, Thermobel Stopray, iplus IGU, ipasol IGU), 4-16-4 reference unit AGC Glass Europe, 2019
  2. Pilkington Insulight TRIPLE 4/12/4/12/4 triple IGU with 2 x offline coated glass (EPD S-P-02592) Pilkington (NSG Group), via EPD International, 2023
  3. Potential impact of high performance glazing on energy and CO2 savings in Europe (TNO 2019 R10442) TNO, 2019
  4. Choosing 'High energy performance' glazing in windows Glass for Europe, 2023
  5. Understanding thermal performance of glazed facades (D E V S Kiran Kumar) TERI, 2012
  6. High Performance Glazing nZEB India, 2019
  7. Window types and technologies US Department of Energy, Energy Saver
  8. Advances in glazing products part 1: anatomy and performance of conventional glazing Enclos, 2024
  9. Expert series: insulating glass, the history, evolution and mechanics of the IGU Guardian Glass, 2020
  10. The science of low-e coatings Vitro Architectural Glass
  11. Gas filling for thermal conductivity Energy Education, University of Calgary