Material Insights · Understanding the Material World

Insulating glass unit: Footprint

Raw materials in one unit

Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions

VariantMaterialAmount (kg)ThroughEmission factor (kg CO2e per kg)Emissions (kg CO2e)
ArgonSilica sand13.38Flat glass sheet– –
ArgonSoda ash2.76Flat glass sheet– –
ArgonCrushed stone2.76Flat glass sheet– –
ArgonAdhesives and sealants0.33– – –
ArgonAluminium0.2– 14.83
ArgonZeolites0.07– – –
ArgonArgon0.026– – –
ArgonSilver0– – –
TripleSilica sand20.07Flat glass sheet– –
TripleSoda ash4.14Flat glass sheet– –
TripleCrushed stone4.14Flat glass sheet– –
TripleAdhesives and sealants0.5– – –
TripleAluminium0.3– 14.84.4

Worked out from data

The site's estimate

Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors

VariantStagePlaceEmissions (kg CO2e)Mass covered by factors
ArgonMakingWorld69.91%
ArgonUseWorld-5018100%
ArgonMakingIndia74.61%
ArgonUseIndia-6131100%
TripleMakingWorld88.11%
TripleUseWorld-2969100%
TripleMakingIndia951%
TripleUseIndia-2969100%

Worked out from data

Energy to make it

Energy used to make one unit, by carrier and stage

Energy to make
  • Ht Heat 624 MJ · Manufacturing Argon low-e double Calculated: renewable 45.6 plus non-renewable 578 MJ primary energy per m2, cradle to gate (A1 to A3) [1]. The EPD gives primary energy, not fuel and electricity separately.
  • Ht Heat 696 MJ · Manufacturing Triple Calculated: total renewable (PERT) 59 plus total non-renewable (PENRT) 637 MJ primary energy per m2, cradle to gate (A1 to A3) [2].

Indicative · as of 2026-11-16. Primary energy of all carriers; most of it is the melting of the glass.

Energy in use

Energy one unit uses per year of use, by carrier

Energy in use 4
  • El Electricity -175 kWh per year · lifetime 30 years Argon low-e double (solar control, SHGC 0.27) Upper bound, calculated, India, against clear single glass. Step 1: solar factor of clear single glass 0.87 [3] minus India's ECBC maximum SHGC of 0.27 for windows not facing north [6] = 0.60. Step 2: most of India receives 4 to 7 kWh of sun per m2 a day [44]; at the low end, 4 kWh/m2/day x 365 days = 1,460 kWh/m2 a year. Step 3: heat kept out = 0.60 x 1,460 kWh/m2 = 876 kWh of heat per m2 of glass a year. Step 4: divided by a seasonal efficiency (ISEER, kWh of cooling per kWh of electricity) of 5.00, the top of BEE's 2021 star range of 3.30 to 5.00 for split units [45]: 876 / 5.00 = about 175 kWh of electricity per m2 a year. At 7 kWh/m2/day and ISEER 3.30 the same steps give about 465 kWh. Both overstate a real window's saving: the radiation figure is for flat ground, which gets more sun than a wall, and not all heat let in has to be removed by air conditioning. Negative means energy saved.
  • Ht Heat -223 kWh per year · lifetime 30 years Air-filled double Upper bound, calculated: heat saved per m2 against single glass, EU average climate: (5.8 minus 2.9) W/m2K [3] x 3,199 heating degree days (K day, base 18 degrees Celsius, EU average of 42 years of data) [11] x 24 h = 223 kWh. It ignores solar gain and frames, and centre-of-glass U-values are better than whole windows.
  • Ht Heat -345 kWh per year · lifetime 30 years Argon low-e double Upper bound, calculated as above with Ug 1.3 W/m2K [3]: (5.8 minus 1.3) x 3,199 x 24 h = 345 kWh per m2 per year.
  • Ht Heat -392 kWh per year · lifetime 30 years Triple Upper bound, calculated as above with Ug 0.7 W/m2K [3]: (5.8 minus 0.7) x 3,199 x 24 h = 392 kWh per m2 per year.

Estimate · as of 2026-11-16. All savings are against clear single glass and are upper bounds resting on catalogue U-values and solar factors. At India's 2023-24 weighted average grid factor of 0.727 tCO2 per MWh [12], 175 kWh is about 127 kg CO2 a year (calculated), about three times the 39.2 kg CO2e of making a unit.

Emissions by stage

Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant

StageValueUnitShareVariantPlaceYearSource
Making39.2kg CO2e per m2, cradle to gate (A1 to A3)89.7Argon low-e doubleEurope2019[1]
Logistics4.09kg CO2e per m2 (A4, transport to site)9.4Argon low-e doubleEurope2019[1]
Use– not declared in the EPD; see energy in use– Argon low-e doubleEurope2019[1]
End of life0.41kg CO2e per m2 (calculated: total life cycle 43.7 minus 39.2 minus 4.09; landfill scenario)0.9Argon low-e doubleEurope2019[1]
Making48kg CO2e per m2, cradle to gate (A1 to A3); share of 49.3 total (calculated: sum of declared modules)97.4TripleEurope2023[2]
Logistics0.622kg CO2e per m2 (A4 transport to site 0.567 plus A5 installation 0.0545, calculated)1.3TripleEurope2023[2]
Use0.079kg CO2e per m2 (B2 maintenance)0.2TripleEurope2023[2]
End of life0.599kg CO2e per m2 (C2 transport 0.259 plus C4 landfill 0.340, calculated)1.2TripleEurope2023[2]

as of 2026-11-16. Two declarations, not a survey. AGC's 2026 figure for its standard 4 mm float pane is 9.8 kg CO2e per m2 [28], so two such panes would be about half of the 39.2 (calculated); the declaration's own glass dates from 2016.

End of life

What happens to a unit when it is thrown away: collection, reuse, recycling and disposal shares, by place

RouteSharePlaceYearSource
Landfill (declared worst-case scenario: 100% of the unit)100Europe2019[1]
Landfill (module C4 models the whole unit as landfilled)100Europe2023[2]
Flat-glass cullet returned to float glass (closed loop), not IGU specific19Germany2022[25]
Flat-glass cullet sent to container glass45Germany2022[25]
Flat-glass cullet landfilled4Germany2022[25]

as of 2026-11-16. The first two rows are modelling assumptions in EPDs. The German rows are shares of about 521,000 tonnes of flat-glass cullet a year, from old buildings and glass processing [25]; the 2024 article takes them from the German Flat Glass Association (2022).

End of life in India

Collection and recycling in India, including the informal sector

IGUs fall under waste code 17-02-02 and are declared as landfill in EPDs [2][1], although high-quality units last several decades [25]. Glass for Europe judges reuse of old units unsustainable because their U-values are poor [27]. India recycles only about 1% of construction and demolition waste [38]. The 2025 waste rules start extended producer responsibility from 1 April 2026 but do not count glass in the reuse target [24]. No source on IGUs in India's informal sector was found.

as of 2026-11-16

Sources

  1. Environmental Product Declaration: Low-e/solar control double glazing units (Thermobel, Thermobel Stopray, iplus IGU, ipasol IGU), 4-16-4 reference unit AGC Glass Europe, 2019
  2. Pilkington Insulight TRIPLE 4/12/4/12/4 triple IGU with 2 x offline coated glass (EPD S-P-02592) Pilkington (NSG Group), via EPD International, 2023
  3. Potential impact of high performance glazing on energy and CO2 savings in Europe (TNO 2019 R10442) TNO, 2019
  4. Energy Conservation Building Code-2017 (ECBC Session 1 training slides) Bureau of Energy Efficiency, India, 2021
  5. Heating and cooling degree days statistics Eurostat, Statistics Explained, 2024
  6. C&D waste rules 2025 welcome move, but codes need an update now more than ever (Rajneesh Sareen and Mitashi Singh) Down To Earth, 2025
  7. Hot topic at glasstec 2024: circular economy in the flat glass industry glasstec
  8. Reuse, remanufacturing, recycling: the case of glass for buildings Glass for Europe, 2025
  9. India's construction boom and the waste challenge: policies, gaps, and data Centre for Advanced Governance (CAG), 2026
  10. India's rising solar sector (Kanika Verma) Invest India, 2021
  11. BEE Notifies New Energy Performance Standards for Air Conditioners (press release) Press Information Bureau, Ministry of Power, 2020