Which unit, study and year the composition figures describe, and how they vary

Composition follows one AGC declaration for a 4-16-4 low-e argon unit (data year 2016, published 2019) [1] and one Pilkington declaration for a 4/12/4/12/4 triple unit (2023) [2]. Spacer mass depends on its material [1]. Sand, soda ash and limestone sit inside the flat glass sheet node; the coated pane (low-e coated glass) is counted there too until it has a node. Float glass cullet, the tin bath, stainless steel and polyamide spacers, and packaging are named here but not linked as separate nodes.

as of 2026-11-16

Components

The products inside one unit, with quantity, mass share and cost share

Variant 1 Argon low-e double
MaterialRoleAmount in one unitShare of the unit's mass
Flat glass sheetComponent297%
Two 4 mm panes, 20 kg of 20.6 kg per m2 (calculated); glass is about 97% of the unit's mass [1]. Sand, soda ash and lime inputs are counted in the glass node.
Variant 2 Triple
MaterialRoleAmount in one unitShare of the unit's mass
Flat glass sheetComponent397%
Three 4 mm panes, 30 kg of 31 kg per m2 [2]; two are offline coated glass.

as of 2026-11-16

Direct materials

The commodities and chemicals in one unit as bought, with amount, mass share, cost share and recycled content

Variant 1 Argon low-e double
MaterialRoleAmount in one unitShare of the unit's mass
Adh Adhesives and sealantsFunctional0.33 kg1.6%
About 30 g polyisobutylene primary seal plus about 300 g polysulfide, silicone or polyurethane outer seal [1] (calculated sum).
Al AluminiumStructural0.2 kgrange 0.15 to 0.26 kg 1%
Spacer bar of about 150 to 260 g depending on material (stainless steel, aluminium or polyamide/steel) [1]; linked to aluminium as an assumption, mid-range used here, share calculated on 20.6 kg.
Zeo ZeolitesFunctional0.07 kg0.3%
Zeolite desiccant, about 70 g per m2 [1].
Ar ArgonFunctional0.026 kg0.1%
14.4 litres, about 25.6 g per m2, at about 90% argon in the gap [1].
Ag SilverFunctional0 kgrange 0 to 0 kg 0.001%
Calculated: a silver layer of 8 to 12 nm [34] at a density of 10.5 g per cm3 is about 0.08 to 0.13 g per m2 per layer. The whole magnetron coating stack is about 1 g per m2 [1].
Variant 2 Triple
MaterialRoleAmount in one unitShare of the unit's mass
Adh Adhesives and sealantsFunctional0.5 kg1.6%
Polymer sealants 0.5 kg per m2 [2].
Al AluminiumStructural0.3 kg1%
Aluminium 0.3 kg per m2 in the declared composition [2].
Zeo ZeolitesFunctionalup to 0.1 kga range, no single figure –
Desiccant is given only as less than 0.1 kg per m2 [2]; assumed zeolite as in the AGC unit.
Ar ArgonFunctionalup to 0.1 kga range, no single figure –
Argon is given only as less than 0.1 kg per m2 in two 12 mm gaps [2].

as of 2026-11-16

How it is put together

The main steps from parts and materials to the finished unit

StepWhat happensTechnologySource
GlassFloat glass is made from about 70 to 75% silica sand, 15% soda ash and 15% limestone and dolomite, plus 15 to 25% crushed recycled glass, melted at 1,500 to 1,600 degrees CelsiusFloat glass[29]
CoatA low-e coating goes on one pane, either onto hot glass in the float line (pyrolytic) or on cold glass in a vacuum (sputtered)– [35]
Spacer frameSpacer bars of aluminium, stainless steel or polymer, holding zeolite desiccant, are formed into a frame that keeps the cavity dry– [1][15][30]
Primary sealPolyisobutylene, the most common primary seal, is applied to the spacer and pressed against the glass– [30][31]
FillArgon replaces air in the gap, to about 90% argon– [1][31]
Secondary sealPolysulfide, silicone or polyurethane fills the channel between spacer and glass edges, bonds the panes and keeps moisture out– [30][31]

as of 2026-11-16

Technologies used to make it

The technologies used to make it, at which step

Made with
  • Gl Glassmaking Melting the sand, soda ash, limestone and cullet batch The float line furnace has a melting zone of about 1,500 to 1,600 degrees Celsius [29].
  • FG Float glass Forming the ribbon of flat glass that each pane is cut from The twin technology; ribbon thickness ranges from about 2 to 19 mm [29].

as of 2026-11-16

Sources

  1. Environmental Product Declaration: Low-e/solar control double glazing units (Thermobel, Thermobel Stopray, iplus IGU, ipasol IGU), 4-16-4 reference unit AGC Glass Europe, 2019
  2. Pilkington Insulight TRIPLE 4/12/4/12/4 triple IGU with 2 x offline coated glass (EPD S-P-02592) Pilkington (NSG Group), via EPD International, 2023
  3. Advances in glazing products part 1: anatomy and performance of conventional glazing Enclos, 2024
  4. A short guide to how glass is made Guardian Glass
  5. Expert series: insulating glass, the history, evolution and mechanics of the IGU Guardian Glass, 2020
  6. TechDirect white paper: understanding IGU specification Viridian Glass, 2025
  7. Silver (low-e sputtering target), The Supply Map PRIA Technologies (PolicyRisk supply map)
  8. The science of low-e coatings Vitro Architectural Glass