The milestones of the product, each with a source

YearEvent
1968Danfoss introduces the VLT 5, with Carlsberg as its first customer; Danfoss calls it the world's first mass-produced frequency converter [23].
1969Strömberg starts work on its first AC drive, a voltage source inverter built on fast thyristors with pulse width modulation [22].
1975Strömberg launches SAMI A and delivers three units to the Karihaara sawmill in northern Finland, its first commercial AC drive [22].
1985SAMI F brings microprocessor-based digital control and vector control [22].
1990ABB says the commercialisation of IGBTs transformed AC drive technology [22].
1992ABB launches the ACS500, its first general-purpose IGBT drive series [22].
1995The ACS600 family brings Direct Torque Control [22].
2021EU rules make IE2 efficiency mandatory for AC drives from 1 July [19].
2025India publishes IS 17123 (Part 9/Sec 1), based on IEC 61800-9-1 [21].

as of 2026-11-17

Lineage

The products and technologies it evolved from and into

Evolved from
  • PE Transformers and power electronics Strömberg's first AC drive (1969) was a thyristor inverter using pulse width modulation; ABB's general-purpose drives were built on IGBTs from 1992 [22].

as of 2026-11-17

Recipe changes

How what it is made of changed over time, and what drove each change

ChangeFromToDriverSource
Power switchThyristors (Strömberg's first drive, 1969)IGBTs (general-purpose drives from 1992)ABB says the commercialisation of IGBTs in 1990 transformed AC drive technology [22][22]
ControlAnalogue electronics (Strömberg's first AC drive, 1969)Microprocessor digital control with vector control (SAMI F, 1985)Not stated in the source [22][22]
Torque controlVector controlDirect Torque Control (ACS600, 1995)Not stated in the source [22][22]

as of 2026-11-17

What could improve it next

Directions for improvement, today's value and the limit

DirectionMetricTodayLimitUnitSource
Put drives on more motorsShare of industrial motors controlled by drives25EU potential of 121.1 TWh a year (9% of motor electricity) on top of 41 TWh already saved% of industrial motors[15][16]
Cut the drive's own lossesConverter efficiency at 80% load, 90 kW drive98.1not stated in any source opened%[3]
Raise part-load efficiencyEfficiency of a 20 hp drive at 12.5% load8697 at full load, same drive%[1]

as of 2026-11-17

Sources

  1. Adjustable Speed Drive Part-Load Efficiency, Motor Systems Tip Sheet #11 US Department of Energy, 2012
  2. Environmental Product Declaration iC7-Automation, Frame FA08 (EPD-IES-0025739:001) Danfoss A/S (The International EPD System), 2026
  3. Study on the energy-saving potential of electric motors with variable-speed drives in the European Union, final report Fraunhofer ICT (Schröder, Liebertseder and Doppelbauer) for CEMEP, 2023
  4. Efficient motors and drives could cut global energy use by up to 10% Drives & Controls (reporting the ABB white paper 'Achieving the COP28 UAE Consensus'), 2025
  5. Ecodesign for motors and drives ABB
  6. IS 17123 (Part 9/Sec 1):2025, Adjustable speed electrical power drive systems, Part 9 Ecodesign for power drive systems, motor starters, Section 1 (identical to IEC 61800-9-1:2017) Bureau of Indian Standards, 2025
  7. Low voltage drives history ABB
  8. The story behind the VLT Fluids Processing (article written by Danfoss Drives), 2013