Raw materials in one unit

Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions

VariantMaterialAmount (kg)ThroughEmission factor (kg CO2e per kg)Emissions (kg CO2e)
StandardSteel11.1– 1.9221.3
StandardCopper7.17Printed circuit board3.96528.4
StandardAluminium4.8– 14.871
StandardHydrochloric acid2.49Printed circuit board– –
StandardHydrogen peroxide1.46Printed circuit board– –
StandardSulphuric acid0.99Printed circuit board– –
StandardPolycarbonate0.9– – –

Worked out from data

The site's estimate

Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors

VariantStagePlaceEmissions (kg CO2e)Mass covered by factors
StandardMakingWorld32880%
StandardUseWorld15,755100%
StandardMakingIndia40980%
StandardUseIndia23,048100%

Worked out from data

Energy to make it

Energy used to make one unit, by carrier and stage

Energy to make
  • El Electricity 37.4 kWh · Manufacturing Calculated, rough: 1.01 kWh per kW of rated power in the 2008 declaration for a 7.5 kW ABB ACS350 [8], times 37 kW. Factory energy only, not the energy in the materials. Scaling by rated power from a much smaller drive is uncertain, since smaller drives use more material per kW.
  • Ht Heat 20.7 kWh · Manufacturing Calculated, rough: 0.56 kWh per kW of rated power in the same 7.5 kW ABB declaration [8], times 37 kW.

as of 2026-11-17

Energy in use

Energy one unit uses per year of use, by carrier

Energy in use
  • El Electricity 3440 kWh per year · lifetime 10 years Standard drive Calculated losses of the drive alone, using the 98.1% efficiency and the use scenario (6,000 active hours a year at an average 80% load) of a 90 kW Danfoss drive [3]: 29.6 kW (37 kW at 80% load) x (1/0.981 - 1) x 6,000 h = about 3,440 kWh. Standby is left out. It does not include the motor, whose use the drive is meant to cut.

as of 2026-11-17

Emissions by stage

Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant

StageValueUnitShareVariantPlaceYearSource
Making330kg CO2e per drive of the rating in the variant column1.25Standard drive, Danfoss iC7 90 kWEU2026[3]
Logistics16.7kg CO2e per drive of the rating in the variant column0.06Standard drive, Danfoss iC7 90 kWEU2026[3]
Use26,000kg CO2e per drive of the rating in the variant column98.64Standard drive, Danfoss iC7 90 kWEU2026[3]
End of life11.6kg CO2e per drive of the rating in the variant column0.04Standard drive, Danfoss iC7 90 kWEU2026[3]
Making884kg CO2e per drive of the rating in the variant column0.85Standard drive, Schneider ATV930 160 kWEurope2019[4]
Logistics15.8kg CO2e per drive of the rating in the variant column0.02Standard drive, Schneider ATV930 160 kWEurope2019[4]
Use103,000kg CO2e per drive of the rating in the variant column99.12Standard drive, Schneider ATV930 160 kWEurope2019[4]
End of life17.4kg CO2e per drive of the rating in the variant column0.02Standard drive, Schneider ATV930 160 kWEurope2019[4]
Making489kg CO2e per drive of the rating in the variant column0.85Standard drive, Schneider ATV630 90 kWEurope2020[5]
Logistics15.8kg CO2e per drive of the rating in the variant column0.03Standard drive, Schneider ATV630 90 kWEurope2020[5]
Use57,200kg CO2e per drive of the rating in the variant column99.1Standard drive, Schneider ATV630 90 kWEurope2020[5]
End of life13.4kg CO2e per drive of the rating in the variant column0.02Standard drive, Schneider ATV630 90 kWEurope2020[5]
Making261kg CO2e per drive of the rating in the variant column3.48Standard drive, Schneider ATV630 7.5 kWEurope2015[7]
Logistics1.91kg CO2e per drive of the rating in the variant column0.03Standard drive, Schneider ATV630 7.5 kWEurope2015[7]
Use7240kg CO2e per drive of the rating in the variant column96.49Standard drive, Schneider ATV630 7.5 kWEurope2015[7]
End of life0.734kg CO2e per drive of the rating in the variant column0.01Standard drive, Schneider ATV630 7.5 kWEurope2015[7]
Making53.7kg CO2e per drive of the rating in the variant column0.45Standard drive, ABB ACS350 7.5 kWEU2008[8]
Use12,008kg CO2e per drive of the rating in the variant column99.55Standard drive, ABB ACS350 7.5 kWEU2008[8]
Making90.1kg CO2e per drive of the rating in the variant column4.02Standard drive, Schneider ATV630 5.5 kWEurope2025[6]
Logistics4.89kg CO2e per drive of the rating in the variant column0.22Standard drive, Schneider ATV630 5.5 kWEurope2025[6]
Use2130kg CO2e per drive of the rating in the variant column95.09Standard drive, Schneider ATV630 5.5 kWEurope2025[6]

as of 2026-11-17. Published studies cover drives of 5.5 to 160 kW, so each row names its drive; none is for 37 kW. In every study the use stage counts only the drive's own losses, not the motor it controls. Logistics includes installation (module A5) where a study gives it. Shares are of each study's total; for the 5.5 kW drive the end-of-life values could not be read, so its shares are of the published total of 2,240 kg. Danfoss gives the use stage as 26,000 kg in its results table but 24,000 kg for the same baseline in its scenario table [3].

Recovered as

The commodities and chemicals recovered at end of life, with recovery rates

Recovered as
  • St Steel Recycling Chassis and cores; the ABB declaration says the main parts can be recycled; rate not found [8].
  • Al Aluminium Recycling Heat sink and frame; the ABB declaration says the main parts can be recycled; rate not found [8].
  • Cu Copper Recycling Windings and busbars; the ABB declaration says the main parts can be recycled; rate not found [8].

as of 2026-11-17

End of life in India

Collection and recycling in India, including the informal sector

No source opened gives collection or recycling rates for drives, in India or elsewhere. ABB's 2008 declaration says the main parts can be recycled, but some must be fragmented to separate the materials [8]. Danfoss counts a credit of 230 kg CO2e beyond the system boundary for a 90 kW drive, against 330 kg for making it [3]. No source says whether India's e-waste rules cover drives.

as of 2026-11-17

Water and waste

Water use and waste per unit where a source gives them

MeasureValueUnitStageYearSource
Hazardous waste in manufacturing, calculated from 0.22 kg per kW of a 7.5 kW drive (rough)8.1kg per 37 kW driveMaking2008[8]
Regular waste to landfill at disposal, calculated from 0.10 kg per kW of a 7.5 kW drive (rough)3.7kg per 37 kW driveEnd of life2008[8]

as of 2026-11-17

Sources

  1. Environmental Product Declaration iC7-Automation, Frame FA08 (EPD-IES-0025739:001) Danfoss A/S (The International EPD System), 2026
  2. Product Environmental Profile: ATV930 160KW 400V with braking unit (ATV930C16N4), ENVPEP1903002_V1 Schneider Electric (PEP ecopassport), 2019
  3. Product Environmental Profile: ATV630 CAB INT IP00/UL type 12 90KW 400V WO KEYPAD (ATV630D90N4ZU), ENVPEP2007013_V1 Schneider Electric (PEP ecopassport), 2020
  4. PEP ecopassport SCHN-00656-V02.01-EN: Altivar Process ATV630, Variable Speed Drive, 5.5kW, 380 to 480V, 3 phases, IP21 (ATV630U55N4) Schneider Electric (PEP ecopassport), 2025
  5. Product Environmental Profile: Altivar Process ATV630U75N4, 7.5 kW (ENVPEP1508010EN_V1, PEP ecopassport SCHN-2015-120) Schneider Electric (PEP ecopassport), 2015
  6. ABB general machinery drives, ACS350, 7.5 kW: Environmental product declaration ABB, 2008