X-ray apparatus: Interventions

Interventions

Changes that would cut emissions or material use, by lever and life stage, with effect per unit, readiness, adoption, evidence and who acts

LeverLife stageChangeEffect per unitReadinessAdoptionWho actsSource
EfficiencyUseSwitch machines to Off or low-power mode at night and at weekendsCOCIR says Off and low-power modes could save 50.5% to 64.3% of daily energy, and Off mode at night and weekends about 3.45 MWh a year per machine [5][6]Deployed (the modes exist)COCIR says the modes are not widely used by users [6]Hospitals and imaging centres[5][6]
EfficiencyComponents designFit a standby mode that cuts power while the system is idleGE HealthCare says standby cuts energy use by 40% against scan mode on the Definium Pace Select [11]DeployedNot statedMakers[11]
CircularityEnd of lifeRefurbish old units and harvest parts for reuseMEPA puts the refurbishment potential of an X-ray unit at 60% (Table 6 value); GE HealthCare says 94% to 96% of most of its systems are reused, refurbished or recycled [4][11]DeployedMakers run take-back programmes; no share of units refurbished found [3][12]Makers, service firms, hospitals[3][4][11][12]
DesignComponents designUse steel instead of lead in wall stands and tube standsRemoves lead from those parts; GE HealthCare cites worker safety and environmental impact, with no mass or emissions figure [11]Deployed (GE HealthCare designs)Not statedMakers[11]
Business modelEnd of lifeManufacturer take-back and refurbishment programmesSystems and components are taken back, refurbished and reused where possible [3][12]; no energy or emissions saving per unit foundDeployedNot statedMakers[3][12]

as of 2026-11-14

Sources

  1. MULTIX Impact | Environmental Product Declaration Siemens Healthcare GmbH (copy held on the Moldovan public procurement portal MTender; no copy found on Siemens Healthineers' own site), 2022
  2. Medical Imaging Equipment: State of Sustainability Research (final, 16 June 2022) Global Electronics Council for the Medical Equipment Proactive Alliance (MEPA), 2022, Table 6 and section 2
  3. COCIR Guidelines for Users on Saving Energy: Good Environmental Practice (X-ray, October 2015) COCIR, 2015
  4. COCIR Self-Regulatory Initiative for the Ecodesign of Medical Imaging Equipment: Status Report 2018 COCIR, 2018, Section 4.4
  5. Focusing on sustainability in X-ray solutions: Definium Pace Select (JB25106XX) GE HealthCare, 2023
  6. OEC One CFD: Compact mobile C-arm (JB33343XX) GE HealthCare, 2025