X-ray apparatus: Interventions
Interventions
Changes that would cut emissions or material use, by lever and life stage, with effect per unit, readiness, adoption, evidence and who acts
| Lever | Life stage | Change | Effect per unit | Readiness | Adoption | Who acts | Source |
|---|---|---|---|---|---|---|---|
| Efficiency | Use | Switch machines to Off or low-power mode at night and at weekends | COCIR says Off and low-power modes could save 50.5% to 64.3% of daily energy, and Off mode at night and weekends about 3.45 MWh a year per machine [5][6] | Deployed (the modes exist) | COCIR says the modes are not widely used by users [6] | Hospitals and imaging centres | [5][6] |
| Efficiency | Components design | Fit a standby mode that cuts power while the system is idle | GE HealthCare says standby cuts energy use by 40% against scan mode on the Definium Pace Select [11] | Deployed | Not stated | Makers | [11] |
| Circularity | End of life | Refurbish old units and harvest parts for reuse | MEPA puts the refurbishment potential of an X-ray unit at 60% (Table 6 value); GE HealthCare says 94% to 96% of most of its systems are reused, refurbished or recycled [4][11] | Deployed | Makers run take-back programmes; no share of units refurbished found [3][12] | Makers, service firms, hospitals | [3][4][11][12] |
| Design | Components design | Use steel instead of lead in wall stands and tube stands | Removes lead from those parts; GE HealthCare cites worker safety and environmental impact, with no mass or emissions figure [11] | Deployed (GE HealthCare designs) | Not stated | Makers | [11] |
| Business model | End of life | Manufacturer take-back and refurbishment programmes | Systems and components are taken back, refurbished and reused where possible [3][12]; no energy or emissions saving per unit found | Deployed | Not stated | Makers | [3][12] |
as of 2026-11-14
Sources
- MULTIX Impact | Environmental Product Declaration Siemens Healthcare GmbH (copy held on the Moldovan public procurement portal MTender; no copy found on Siemens Healthineers' own site), 2022
- Medical Imaging Equipment: State of Sustainability Research (final, 16 June 2022) Global Electronics Council for the Medical Equipment Proactive Alliance (MEPA), 2022, Table 6 and section 2
- COCIR Guidelines for Users on Saving Energy: Good Environmental Practice (X-ray, October 2015) COCIR, 2015
- COCIR Self-Regulatory Initiative for the Ecodesign of Medical Imaging Equipment: Status Report 2018 COCIR, 2018, Section 4.4
- Focusing on sustainability in X-ray solutions: Definium Pace Select (JB25106XX) GE HealthCare, 2023
- OEC One CFD: Compact mobile C-arm (JB33343XX) GE HealthCare, 2025