X-ray apparatus: Working
What it is
The product and the job it does, in a short paragraph
An X-ray apparatus is a machine that sends a controlled beam of X-rays through the body and records the shadow on a detector, so that doctors and dentists can see bones, lungs and teeth. The functional unit is one complete diagnostic X-ray machine, from generator and tube to stand or table, detector and console. CT scanners have their own node; X-ray tubes sold alone, security and industrial X-ray machines and radiotherapy are left out. [3]
as of 2026-11-14
How it works
How it does its job, step by step in plain words
A high-voltage generator feeds an X-ray tube. Inside the tube a heated tungsten filament gives off electrons in a high vacuum, and they strike a metal target [14][15]. Less than 1% of the electrons' energy comes out as X-rays and more than 99% becomes heat [16]. A collimator shapes the beam, which passes through the patient. The flat-panel detectors now common in radiography turn the X-rays that get through into light and then into an electrical signal, using a phosphor such as caesium iodide [13]. A computer in the console processes the image at once, with no film to develop. Mobile units and C-arms use the same chain on wheels or on a rotating arm. The working principle and its history are on the twin technology page.
as of 2026-11-14
Key specifications
The numbers that describe it, each with unit, variant, year and source
| Spec | Value | Unit | Year | Source |
|---|---|---|---|---|
| Weight of one Siemens MULTIX Impact radiography system | 1184 | kg | 2022 | [3] |
| Power drawn with the system in operation (MULTIX Impact) | 392 | W | 2022 | [3] |
| Power drawn with the system in standby (MULTIX Impact) | 340 | W | 2022 | [3] |
| Power drawn with the system off and detectors in standby (MULTIX Impact) | 110 | W | 2022 | [3] |
| Daily energy use of the MULTIX Impact under the declaration's daily profile (see usage pattern) | 5.26 | kWh per day | 2022 | [3] |
| Continuous power in scan mode (GE HealthCare Definium Pace Select) | 2.2 | kVA | 2023 | [11] |
| Power in standby (GE HealthCare Definium Pace Select) | 0.85 | kVA | 2023 | [11] |
| Share of daily energy used in scan mode (COCIR guidance for X-ray equipment) | 3 | % (around) | 2015 | [5] |
as of 2026-11-14
Limits
The physical limits set by science and the engineering limits of today's design, with today's value
| Limit | Kind | Today | Unit | Source |
|---|---|---|---|---|
| Share of the electron beam's energy that leaves the tube as X-rays; more than 99% is heat the tube must shed | Physical | 1 | % (less than) | [16] |
| Refurbishment potential of an X-ray unit (MEPA Table 6 value; the report does not define the term) | Engineering | 60 | % (refurbishment potential) | [4] |
as of 2026-11-14
Science it relies on
The science principles it works by or is limited by
Relies on- X-rays The image is a shadow made by tissue that absorbs X-rays unequally.
- Thermionic emission The tube's electrons come from a heated tungsten filament in a high vacuum [14].
- X-rays X-rays ionise tissue, so EU rules require each dose to fit the medical purpose of the exposure, which caps how much radiation an image may use [21]; regulators also license the equipment [7].
as of 2026-11-14
Sources
- MULTIX Impact | Environmental Product Declaration Siemens Healthcare GmbH (copy held on the Moldovan public procurement portal MTender; no copy found on Siemens Healthineers' own site), 2022
- Medical Imaging Equipment: State of Sustainability Research (final, 16 June 2022) Global Electronics Council for the Medical Equipment Proactive Alliance (MEPA), 2022, Table 6 and section 2
- COCIR Guidelines for Users on Saving Energy: Good Environmental Practice (X-ray, October 2015) COCIR, 2015
- AERB Annual Report 2023, Chapter 2: Safety Surveillance of Radiation Facilities Atomic Energy Regulatory Board, India, 2023, Tables 2.1 and 2.2
- Focusing on sustainability in X-ray solutions: Definium Pace Select (JB25106XX) GE HealthCare, 2023
- Digital radiography: The bottom line comparison of CR and DR technology Applied Radiology (J. Anthony Seibert), 2009
- WE-H-204-01: William D. Coolidge, Inventor of the Modern X-Ray Tube Medical Physics, vol. 43 no. 6 (abstract by David J. Allard), record on OSTI.gov, 2016
- William D. Coolidge Edison Tech Center
- X-ray production Radiopaedia.org
- Council Directive 2013/59/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation legislation.gov.uk (EU text as it stood on 31 December 2020), 2013, Article 5