Direct air capture: Energy footprint
Energy in use
The energy it uses or converts while it works, and how efficiently
- Consumption
- Heat and electricity; the 2018 liquid design needs 8.81 GJ of natural gas, or 5.25 GJ of gas and 366 kWh of electricity, per tonne [6]
- Conversion
- Heat and work separate carbon dioxide from air and compress it; no useful energy comes out
- Unit
- GJ/t CO2
- Note
- The thermodynamic minimum is about 20 kJ per mole [5]; both solid and liquid systems can be built to run on heat only or electricity only [3].
as of 2026-11-11
Energy links
The energy sources and technologies it uses, holds, converts, loses or gets back
Consumes- Ht Heat Solid sorbents are heated to 80 to 120 °C to release the gas, and liquid systems use units at 300 to 900 °C [3].
- El Electricity Fans and compressors run on electricity; one liquid design can use 366 kWh per tonne with less gas [6].
- GeP Geothermal power plants ON Power supplies Mammoth with geothermal energy [8].
as of 2026-11-11
Sources
- Direct Air Capture International Energy Agency
- Economic and energetic analysis of capturing CO2 from ambient air (House, Baclig, Ranjan, van Nierop, Wilcox and Herzog, PNAS 108(51), 20428 to 20433) DSpace@MIT (MIT Libraries), 2011, abstract; the 20 kJ/mol minimum is in the main text (Eq. 2)
- A Process for Capturing CO2 from the Atmosphere (Keith, Holmes, St. Angelo and Heidel, Joule) Belfer Center, Harvard Kennedy School, 2018
- Climeworks switches on world's largest direct air capture plant (press release) Climeworks, 2024