Geothermal direct use and ground-source heat pumps: Levers
Held back most by
Economics
The physics is sound and a ground-source heat pump delivers more heat per unit of electricity than an air-source one (average 4.3 against 3.4 in a German field test) [12], but the Energy Transitions Commission finds the barriers are high up-front cost, siting, policy and consumer trust, not the technology [13]. Lower drilling and installation cost would move it most; for India's hot springs, where the heat is and who may use it matter as much [2][14].
The six layers
Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it
Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A hard limit comes from mathematics or nature and can only be sidestepped; a soft limit moves with effort, scale, money or policy.
- 1 Mathematics Soft limit
Mathematics is the language of its physics
What it gives. A simple heat balance tells a designer how much heat a flow of hot water carries, and so how big a well, pipe and heat exchanger must be [10].
The idea. Physical laws make the water carry heat, and mathematics only writes them down, so the role is language. The heat in a flow of water is its mass flow times its specific heat times the temperature drop [10]. Water holds 4,186 joules in each kilogram for each degree [10].
The limit. The balance gives only the heat in the flow; whether the well keeps flowing, and how hot, depends on a resource the equation does not describe [2].
What could unlock it. A larger flow or a larger temperature drop gives more heat from the same well, up to what the resource can supply [10][2].
Show the maths
P = ṁ × c × ΔT- P
- the heat a flow of water gives up, in watts
- ṁ
- the mass of water flowing each second, in kilograms a second
- c
- the specific heat of water, 4,186 joules for each kilogram and degree
- ΔT
- the temperature drop of the water, in degrees C
In plain words. Hot water carries heat. The more water flows, and the more it cools as it passes through a building or a greenhouse, the more heat it hands over. The sum just multiplies those together, with a number that says how much heat each kilogram of water holds.
Worked example. The source gives Q = mcΔT [10]; dividing by time gives P = ṁ × c × ΔT. With an assumed 10 kg of hot water a second cooled by an assumed 40 degrees C, P = 10 × 4,186 × 40 = about 1.67 MW of heat (calculated) [10].
- 2 Science Hard limit
What it gives. Heat flows by itself only from hot to cold, so a heat pump uses work to lift mild heat from the ground to a warmer room; where hot water rises from the ground, no lifting is needed [11][2].
The idea. A heat pump delivers more heat than the electricity it uses, but there is a ceiling set by the two temperatures. The best possible heat delivered per unit of work is one over the Carnot efficiency, with temperatures in kelvin [11]. For ground at 10 degrees C heating water to 35 degrees C it is 12.3 (calculated) [11].
The limit. Carnot limit: the heat a pump can deliver per unit of electricity falls as the gap between the ground and the heated water widens, and cannot exceed 1 ÷ (1 - Tc ÷ Th) [11].
What could unlock it. Warmer ground, and heating at low temperature through floors or large radiators, shrink the temperature lift and raise the ceiling; real units fall short of it, and the field test's best ground-source unit reached 5.4 [11][12].
Show the maths
COPhp = 1 ÷ EffC, EffC = 1 - Tc ÷ Th- COPhp
- the most heat delivered for each unit of work, a pure number
- EffC
- the Carnot efficiency, a fraction
- Th
- the temperature of the heated water, in kelvin
- Tc
- the temperature of the heat source, the ground, in kelvin
In plain words. A heat pump moves heat uphill, like a pump moving water uphill. The shorter the hill, the less work it needs. The best case is set only by the two temperatures. Real pumps have losses, so they fall short of it, but a short hill still means a better pump.
Worked example. With Th = 308.15 K (35 degrees C) and Tc = 283.15 K (10 degrees C), EffC = 1 - 283.15 ÷ 308.15 = 0.0811, so COPhp = 1 ÷ 0.0811 = 12.3 (calculated) [11].
- 3 Engineering Soft limit
What it gives. A ground loop of buried pipe or a borehole carries heat between the ground and a heat pump, or a well brings hot water to a heat exchanger [2][13].
The idea. In a German field test of 77 heat pumps over four years, the 16 ground-source systems averaged an annual performance factor of 4.3, with a range of 3.6 to 5.4, against an average seasonal performance factor of 3.4 for air-source units [12]. The Energy Transitions Commission gives typical coefficients of 4 to 5 for ground-source and 3 to 4 for air-source [13].
The limit. Heat reaches a borehole only by slow conduction through the ground, whose rate grows with area and temperature difference, so more heat means more or longer boreholes, and siting varies [13][16].
What could unlock it. Careful design and installation matter: the field test's ground-source units ranged from 3.6 to 5.4 against an average of 4.3 [12].
HP Heat pumps, air conditioning and refrigerationDHN District heating and cooling networks
- 4 Production Soft limit
What it gives. Heat pumps are made in factories, but boreholes are drilled on site by crews, so the installation is a local trade [13].
The idea. The Energy Transitions Commission counts about 6.5 million ground-source heat pumps with about 78 GW of thermal capacity worldwide [13]. In 2020, ground-source heat pumps were 59% of the 107 GW of direct-use capacity reported by 88 countries [2].
The limit. The scarce input is skilled drilling labour: the commission notes the drilling workforce is limited in places with no existing or transferable workforce [13].
What could unlock it. The shortage is smaller where a drilling workforce already exists or can be transferred [13], and India's national policy sets capacity building and knowledge sharing as a goal [14].
- 5 Economics Soft limit Binds most today
What it gives. A ground-source pump saves running cost against an air-source pump but costs more to install, so the sale depends on how long the buyer waits for the saving [13].
The idea. The Energy Transitions Commission says ground-source pumps typically have higher up-front cost than air-source pumps but lower levelised cost of heat [13]. ESMAP's US-based estimate for direct-use heat is USD 15 to 105 a megawatt-hour, average USD 54, over 30 years at a 5% discount rate [2]. Project preparation may need up to 30% of capital before the resource is proven [2].
The limit. High up-front capital: the commission names it, with siting, policy and consumer trust, as the main barrier [13].
What could unlock it. Lowering up-front cost is what the commission says must change, since the barrier is cost and not technology [13].
Show the maths
heat cost per kWh = electricity price per kWh ÷ SPF- heat cost per kWh
- the running cost of each kilowatt-hour of heat, in rupees
- electricity price per kWh
- what the buyer pays for each kilowatt-hour of electricity, in rupees
- SPF
- the seasonal performance factor: heat delivered over a year divided by electricity used, a pure number
In plain words. A heat pump uses one unit of electricity to deliver several units of heat. The more heat per unit of electricity, the lower the running cost of the heat. A ground-source pump gets more heat per unit, so it costs less to run, but it costs more to buy and install.
Worked example. For an assumed electricity price of Rs 8 a kWh (assumed) and the German field test's averages of 4.3 for ground-source and 3.4 for air-source [12], the running cost is 8 ÷ 4.3 = Rs 1.86 and 8 ÷ 3.4 = Rs 2.35 a kWh of heat, about 21% less (calculated) [12].
- 6 Resources and rules Soft limit
What it gives. Hot springs and wells must be near a use for the heat, and ground loops need land, a drilling permit and demand for heat or cooling [2][14].
The idea. ESMAP says low use comes from a mismatch between the resource's location and the process that needs the heat, little familiarity and small projects that investors ignore [2]. In India the Geological Survey has identified 381 hot springs at 35 to 89 degrees C and 10 geothermal provinces [14]. Project InnerSpace estimates more than 1,500 GW of geothermal cooling potential and recommends a national geothermal cooling mission [15].
The limit. Where the heat is, where it is wanted and who may drill limit direct use; India's 2025 policy sets no numeric target, and pilot projects on power and direct use are to be taken up under MNRE's research scheme [2][14].
What could unlock it. Direct-use pilots, which the policy provides for, and a national geothermal cooling mission, which Project InnerSpace recommends, would test demand [14][15].
HP Heat pumps, air conditioning and refrigerationDHN District heating and cooling networks
as of 2026-11-23
Sources
- Direct Utilization of Geothermal Resources World Bank, Energy Sector Management Assistance Program (ESMAP), 2022, Technical Report 021/22 (printed "Technical Report 21/22" on the cover); executive summary and chapter 1
- 14.2 Temperature Change and Heat Capacity (College Physics for AP Courses) OpenStax, 2022
- 15.5 Applications of Thermodynamics: Heat Pumps and Refrigerators (College Physics, undated page) OpenStax, 2026
- Fraunhofer ISE research project completed: heat pumps provide climate-friendly heating in existing buildings Fraunhofer ISE, 2025
- Beneath the Surface technology fact sheet: Ground source heat pumps (July 2026) Energy Transitions Commission, 2026
- National Policy on Geothermal Energy Ministry of New and Renewable Energy, Government of India, 2025
- India executive summary (undated) Project InnerSpace, 2026
- 14.5 Conduction OpenStax, College Physics 2e