Geothermal direct use and ground-source heat pumps: Energy footprint
Energy in use
The energy it uses or converts while it works, and how efficiently
- Consumption
- Electricity for heat-pump compressors and circulation pumps; pumping power only for direct use of hot water
- Conversion
- None to electricity: ground heat is moved into buildings by a heat pump, or hot water's heat passes through a heat exchanger
- Unit
- seasonal performance factor (heat out per unit of electricity)
- Note
- 13 ground-source heat pumps in existing German homes reached seasonal performance factors of 3.6 to 5.4 in 2024 [5]; geothermal space heating worldwide ran at a capacity factor of about 0.4 in 2019 [2].
as of 2026-11-11
Energy links
The energy sources and technologies it uses, holds, converts, loses or gets back
Consumes- Geo Earth's heat Direct use takes heat from hot water held in rock, brought up by production wells [2].
- Amb Ambient heat Ground-source heat pumps draw on shallow ground held at about 4.5 to 21 °C all year [3].
- El Electricity A heat pump needs electricity to run its compressor [2].
- Ht Heat The system delivers heat for space heating, bathing, greenhouses, aquaculture and drying [2].
as of 2026-11-11
Sources
- Direct Utilization of Geothermal Resources World Bank, Energy Sector Management Assistance Program (ESMAP), 2022, Technical Report 021/22 (printed "Technical Report 21/22" on the cover); executive summary and chapter 1
- Geothermal Heat Pumps (Energy Saver) US Department of Energy, 2024
- HP-QA in Existing Buildings (WP-QS im Bestand) Fraunhofer Institute for Solar Energy Systems ISE