Material Insights · Understanding the Material World

Electric motor: Footprint

Raw materials in one unit

Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions

VariantMaterialAmount (kg)ThroughEmission factor (kg CO2e per kg)Emissions (kg CO2e)
InductionSteel606– 1.921163.5
InductionCopper69– 3.965273.6
InductionAluminium19– 14.8281.2
PermanentIron ore0.869Permanent magnet– –
PermanentRare earths0.378Permanent magnet– –
PermanentNickel0.014Permanent magnet– –
PermanentBoron0.013Permanent magnet– –

Worked out from data

The site's estimate

Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors

VariantStagePlaceEmissions (kg CO2e)Mass covered by factors
InductionMakingWorld1718100%
InductionUseWorld2.91 million100%
InductionMakingIndia1718100%
InductionUseIndia4.26 million100%
PermanentMakingWorld8.080%
PermanentUseWorld– –
PermanentMakingIndia11.80%
PermanentUseIndia– –

Worked out from data

Energy in use

Energy one unit uses per year of use, by carrier

Energy in use
  • El Electricity 254,500 kWh per year · lifetime 25 years Induction motor Calculated for the 37 kW IE3 motor at full load: 37 kW times 6,500 h a year divided by an efficiency of 94.5% [4].
  • El Electricity 1.29 kWh per 100 km (lost as heat) Permanent magnet motor Drive-cycle loss of the 100 kW traction motor is 12.9 Wh/km (calculated to 100 km); the induction machines lose 14.2 to 16.3 Wh/km [5].

as of 2026-11-13

Emissions by stage

Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant

StageValueUnitShareVariantPlaceYearSource
Making637kg CO2e per motor0.03Induction motor (37 kW, IE3, cast iron)Europe2024Calculated from [4]: upstream (raw materials and inbound transport) 16.2 plus core manufacturing 1.01 kg CO2e per kW, times 37 kW
Logistics50kg CO2e per motor0.003Induction motor (37 kW, IE3, cast iron)Europe2024Calculated from [4]: distribution 0.864 plus installation 0.489 kg CO2e per kW, times 37 kW
Use1.93 millionkg CO2e per motor99.96Induction motor (37 kW, IE3, cast iron)Europe2024Calculated from [4]: use and maintenance 5.22E4 kg CO2e per kW, times 37 kW; 25 years at 6,500 h a year, European grid mix
End of life20kg CO2e per motor0.001Induction motor (37 kW, IE3, cast iron)Europe2024Calculated from [4]: deinstallation and end of life 0.538 kg CO2e per kW, times 37 kW
Making270kg CO2e per motor– Permanent magnet motor (100 kW car traction)Europe2026Calculated from [5]: 1.35 g CO2e/km for producing the motor over 200,000 km; made in Europe with magnets from China; the magnet supply chain alone is about 72 kg (64 kg with older data)

as of 2026-11-13. The EPD gives results per kW of mechanical power over 25 years for a 37 kW motor, in the columns upstream, manufacturing, distribution, installation, use and maintenance, and deinstallation and end of life; each is multiplied by 37 kW (calculated). Upstream and manufacturing make up making; distribution and installation make up logistics. Over 97% of lifetime emissions also come from use in a study of motors running 4,000 hours a year [2].

End of life

What happens to a unit when it is thrown away: collection, reuse, recycling and disposal shares, by place

RouteSharePlaceYearSource
Recycled95Europe (scenario assumed in the EPD)2024[4]
Landfill5Europe (scenario assumed in the EPD)2024[4]

as of 2026-11-13

Recovered as

The commodities and chemicals recovered at end of life, with recovery rates

Recovered as
  • St Steel Recycling Cores and frame; the EPD assumes 95% of the motor is recycled overall [4].
  • Cu Copper Recycling Winding wire; the EPD assumes 95% of the motor is recycled overall [4].
  • Al Aluminium Recycling Rotor cage and housing parts; the EPD assumes 95% of the motor is recycled overall [4].

as of 2026-11-13

End of life in India

Collection and recycling in India, including the informal sector

The sources give no recycling rate for India. They do show that failed motors are often rewound, and rewinding can cut a motor's efficiency by up to 5% [9]. A national replacement programme has swapped about 5,000 old motors for IE3 and IE4 ones, saving 9,150 MWh a year [9]. The collection of end-of-life motors and of magnets is not described in the sources found.

as of 2026-11-13

Sources

  1. Environmental Product Declaration (EPD): W22 Cast Iron Electric Motor (37kW), EPD-IES-0017771 WEG, registered with EPD International AB, 2024, Environmental indicators table (GWP-total row) and scenario text
  2. Life cycle assessment of electric traction induction machines (Hsieh, Nordelof, Grunditz and Thiringer, International Journal of Life Cycle Assessment 31, 16) Springer, 2026, Tables 1 to 3 and sections 4.4 to 4.6
  3. Setting Standards: Key government initiatives to improve motor efficiency Powerline (India trade magazine), 2026